For a Robertshaw 9600 thermostat, the wire connections are as follows:
- RC (Red) – Power from cooling transformer - W (White) – Heating control - Y (Orange) – Cooling control - G (Bluish Green) – Fan control
Ensure that any factory-installed jumpers are removed as needed. If using dual transformers for heating and cooling, they must be in phase to avoid damage.
This answer is automatically generated
Gina
April 10, 2025
My 9600 thermostat controls a room with radiant heat. Does it matter if the Auto - on switch stays on "auto" or "on"? I don't think there is a fan anywhere.
1 comments:
Mr. Anderson
April 10, 2025
Radiant heat systems typically do not use a blower fan. Therefore, the Auto - On switch on a Robertshaw 9600 thermostat should be set to "AUTO" to prevent the fan from running unnecessarily.
This answer is automatically generated
Gina Vinciguerra
April 10, 2025
If daily operation is on programmed settings, but you want to do a temporary program override to get more heat for a short time, do you have to put it on manual before raising the temperature?
Thanks
1 comments:
Mr. Anderson
April 10, 2025
No, the Robertshaw 9600 does not require switching to manual mode for a temporary program override. You can temporarily increase or decrease the temperature by pressing the up or down button, and the thermostat will return to the programmed schedule at the next scheduled setting change.
This answer is automatically generated
Larry Bean
March 16, 2025
heater not going on, window just displays "Low Bat" and Ive changed batteries. **** works not heat.
1 comments:
Mr. Anderson
March 16, 2025
The Robertshaw 9600 thermostat is not turning on and continues to display "Low Bat" even after changing the batteries because the thermostat may be defective. The user has already replaced the batteries with new alkaline ones and checked the fuses, but the issue persists. This suggests that the internal computer board may have failed, requiring a thermostat replacement.
This answer is automatically generated
Steven King
June 23, 2025
My thermostat will stop blowing air even though the switch is on "on" once the temperature reading reaches one degree above or below its set temperature. How do I keep the fan on so it keeps blowing air?
Graham jensen
June 4, 2025
How to change from Fahrenheit to celcius
Dallis E. Widick
May 5, 2025
changing from Centigrade to Fahrenheit
Phil D
April 19, 2025
MY thermostat won't change from Celcius to frahrenheit.
9600 DIGITAL PROGRAMMABLE THERMOSTAT ® ™ I N T E G R A T E D C O M F O R T S O L U T I O N S ELECTRIC 5 - 2 Day Programmable 1 Heat / 1 Cool User’s Manual...
Features • Four setpoints for weekday programming—two setpoints for weekend comfort. • Two AA ENERGIZER brand batteries retain program memory even during power outages. • Low battery indicator. • Fahrenheit/Celsius display option. • Programmable from 45°F (4°C) to 90°F (32°C). •...
Figure 1 Installing Item 9600 Thermostat NOTE: F , 4-5 OR NEW INSTALLATIONS MOUNT THERMOSTAT ON AN INSIDE WALL FEET ABOVE THE FLOOR O NOT INSTALL BEHIND A DOOR IN A CORNER NEAR AIR VENTS IN DIRECT SUNLIGHT OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES...
Figure 3 MOUNTING HOLES PROG MORN DAY EVE NITE CHANGE AUTO/MAN Elec COOL OFF HEAT FAN AUTO ON 7. Drill the marked holes using a 3/16” drill bit. Note: Enclosed plastic anchors do not require a drilled hole for drywall. 8.
13. Install two AA ENERGIZER brand batteries or equivalent into battery compartment. Be sure to match positive (+) ends of batteries with positive (+) battery terminals in the battery compartment. The display will show as follows: 14. Replace cover on thermostat by snapping into place. 15.
3. Press Press SET P to change temperature differential* 1°. T EMPERATURE IFFERENTIAL IS ACTORY PRESET AT HIS MEANS THAT WHENEVER THE ROOM TEMPERATURE CHANGES BY ONE FULL DEGREE FROM THE TEMPERATURE SETTING THE SYSTEM WILL TURN ON F THE SYSTEM TURNS ON TOO OFTEN INCREASE THE TEMPERATURE DIFFERENTIAL Changing Fahrenheit (F) to Celsius (C)
4. Press SET. SET PR PROG SET PROG/MAN COOL-OFF-HEAT AUTO - ON 5. Press to change MORN temperature. 6. Repeat Steps 2-5 for DAY, EVE, and NITE. COOL-OFF-HEAT 7. Shift COOL-OFF-HEAT switch to HEAT position. 8. Repeat steps 2-6 to program HEAT (winter) settings. NOTE: OTH SUMMER AND WINTER PROGRAMS USE THE SAME TIME SETTINGS Your thermostat is now programmed for summer and winter operation.
Temporary Program Override To temporarily increase or decrease temperature: Press PROG SET PROG/MAN COOL-OFF-HEAT AUTO - ON The thermostat will automatically return to the program at the next scheduled setting change. Manual Operation 1. Press PROG/MAN until indicator is in MAN position. PROG T PROG/MAN PROG...
To Test Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY. CAUTION: D 50°F O NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE IS BELOW (10°C).
Troubleshooting Symptom Remedy Thermostat does not turn Check wiring. on system. (See INSTALLATION) Check fuse. Replace with 2 amp Slo-Blo fuse if fuse has opened. Thermostat turns on and off too Increase temperature differential. frequently. (See PROGRAMMING) Display is blank, flashing or Replace batteries.
Wiring Diagrams The following is just a sample of the most common types of HVAC sys- tems. Refer to your system’s installation manual for wiring information. HEAT ONLY HEAT/COOL 4-WIRE 3-WIRE SINGLE TRANSFORMER SINGLE TRANSFORMER Factory-Installed Factory-Installed jumper jumper Transformer Transformer 24 VAC 120 VAC...
Maple Chase Company warrants to the original contractor installer or to the original consumer user, each new Robertshaw thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from date of purchase. This warranty...
Need help?
Do you have a question about the 9600 and is the answer not in the manual?
Questions and answers
How do I hook up the colored wires
For a Robertshaw 9600 thermostat, the wire connections are as follows:
- RC (Red) – Power from cooling transformer
- W (White) – Heating control
- Y (Orange) – Cooling control
- G (Bluish Green) – Fan control
Ensure that any factory-installed jumpers are removed as needed. If using dual transformers for heating and cooling, they must be in phase to avoid damage.
This answer is automatically generated
My 9600 thermostat controls a room with radiant heat. Does it matter if the Auto - on switch stays on "auto" or "on"? I don't think there is a fan anywhere.
Radiant heat systems typically do not use a blower fan. Therefore, the Auto - On switch on a Robertshaw 9600 thermostat should be set to "AUTO" to prevent the fan from running unnecessarily.
This answer is automatically generated
If daily operation is on programmed settings, but you want to do a temporary program override to get more heat for a short time, do you have to put it on manual before raising the temperature? Thanks
No, the Robertshaw 9600 does not require switching to manual mode for a temporary program override. You can temporarily increase or decrease the temperature by pressing the up or down button, and the thermostat will return to the programmed schedule at the next scheduled setting change.
This answer is automatically generated
heater not going on, window just displays "Low Bat" and Ive changed batteries. **** works not heat.
The Robertshaw 9600 thermostat is not turning on and continues to display "Low Bat" even after changing the batteries because the thermostat may be defective. The user has already replaced the batteries with new alkaline ones and checked the fuses, but the issue persists. This suggests that the internal computer board may have failed, requiring a thermostat replacement.
This answer is automatically generated
My thermostat will stop blowing air even though the switch is on "on" once the temperature reading reaches one degree above or below its set temperature. How do I keep the fan on so it keeps blowing air?
How to change from Fahrenheit to celcius
changing from Centigrade to Fahrenheit
MY thermostat won't change from Celcius to frahrenheit.