4.6 Output and Overload Lights

1. The output indicator light (Green) will remain illuminated during normal operating conditions.
2. If the generator is overloaded (in excess of 2.0 kW), or if there is a short in the connected appliance,
the output indicator light (Green) will go out, the overload indicator light (Red) will turn on and current
to the connected appliance will be shut off.
3. Remove all electrical loads from the generator and investigate the cause of the overload.
4. To reset the overload condition (Red light), stop and restart the generator. The (Green) indicator light
should be illuminated within 10 seconds.
120 V - 20A Duplex
ON
OFF
ON
OFF
■ Before connecting or reconnecting an appliance to the generator, check that it is
in good order, and that its electrical rating does not exceed that of the generator.
■ When an electric motor is started, the overload indicator light (Red) may go on
momentarily while the output indicator light (Green) remains on. This is not a
problem as long as the overload light only flickers on briefly.
Receptacle
18
Overload Light