Baxi Brazilia F5 Installation And Owner's Manual

Baxi Brazilia F5 Installation And Owner's Manual

Balanced flue gas wall heaters

Advertisement

© Baxi Heating U.K. Limited 2010.
Baxi Brazilia F 5, F 5S, F 8S &
Comfortstat 2 F 8ST
Balanced Flue Gas Wall Heaters
Baxi Brazilia F 5
Baxi Brazilia F 8S
Installation and Owner
Guide.
Baxi Brazilia F 5S
Baxi Brazilia F 8ST Comfortstat 2
Please leave these instructions with the user
5131922 / 04

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Brazilia F5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Baxi Brazilia F5

  • Page 1 Please leave these instructions with the user © Baxi Heating U.K. Limited 2010. Baxi Brazilia F 5, F 5S, F 8S & Comfortstat 2 F 8ST Balanced Flue Gas Wall Heaters Installation and Owner Guide. Baxi Brazilia F 5 Baxi Brazilia F 5S...
  • Page 2 The Company Secretary, Baxi Heating UK We hope you get a satisfactory service from Baxi. If Limited, Brooks House, Coventry Road, Warwick, not, please let us know.
  • Page 3: Table Of Contents

    © Baxi Heating U.K. Limited 2010. Installer Guide Contents Section Page(s) Installer guide 3 - 17 Introduction 4 - 5 Technical Data 6 - 7 Site Requirements 8 - 10 Installation Commissioning the Appliance Annual Servicing Changing Components 14 - 17...
  • Page 4: Installer Guide

    This is Description indicated on the information label. 1. The Baxi Brazilia F is a range of room sealed gas convector appliances designed to be used with gas type G20 (Natural Gas) at supply pressure 20 mbar.
  • Page 5 © Baxi Heating U.K. Limited 2010. Installer Guide 1.0 Introduction Installation 1. The appliance is suitable for installation only in G.B. and I.E. and should be installed in accordance with the rules in force. For Ireland install in accordance with I.S.813 “Domestic gas installations”.
  • Page 6: Technical Data

    © Baxi Heating U.K. Limited 2010. Installer Guide 2.0 Technical Data F 5 & F 5S Natural Gas F 8S & F 8ST Natural Gas Category of Appliance F 8S II 2H3P Category of Appliance F 8ST I Category of Appliance 2H3P The appliance is set for Gas Type G20 at 20mbar.
  • Page 7 © Baxi Heating U.K. Limited 2010. Installer Guide 2.0 Technical Data F 5 & F 5S Propane F 8S Propane (When converted using kit No. 5110284) (When converted using kit No. 5110285) Category of Appliance Category of Appliance 2H3P 2H3P The appliance is set for Gas Type G31 at 37mbar.
  • Page 8: Site Requirements

    © Baxi Heating U.K. Limited 2010. Installer Guide 3.0 Site Requirements Location 1. The appliance must be fitted on a suitable outside wall to meet the requirements of the balanced flue arrangement. 2. For applications involving walls constructed from or comprising of combustible material, reference should be made to the requirements of B.S.
  • Page 9 F From internal or external corners. clear of any part of the terminal. A suitable guard G Above ground, roof or balcony level. is available direct from Baxi Heating, Part No. H From a surface facing a terminal. From a terminal facing a terminal.
  • Page 10 © Baxi Heating U.K. Limited 2010. Installer Guide 3.0 Site Requirements Flue Dimensions 1. The standard appliance is supplied with flue ducting which is adjustable to accommodate wall thicknesses from 248mm (9 in) to 349mm in). Flue Option 2. Three further flue terminals are available as F8S &...
  • Page 11: Installation

    © Baxi Heating U.K. Limited 2010. Installer Guide 4.0 Installation Preparation 1. Ensure that the length of the flue ducting is suitable for the wall thickness. 2. Select a position for the appliance. Using the template supplied, mark the position of the flue ducting and the four fixing holes.
  • Page 12: Commissioning The Appliance

    © Baxi Heating U.K. Limited 2010. Installer Guide 5.0 Commissioning the Appliance Commissioning the Appliance 1. Turn on the gas service cock. 2. Where applicable, fit the control knob onto the control tap spindle (Fig. 12). 3. Purge any air from the system.
  • Page 13: Annual Servicing

    © Baxi Heating U.K. Limited 2010. Installer Guide 6.0 Annual Servicing Servicing the Appliance 1. For reasons of safety and economy the appliance should be serviced annually. Outer Case 2. Before servicing please read Section 1.3 Important Information. Fig. 15 3.
  • Page 14: Changing Components

    © Baxi Heating U.K. Limited 2010. Installer Guide Fig. 21 7.0 Changing components on models without the Comfortstat control Changing Components 1. Before changing any components please read Section 1.3 Important Information. Mounting Lugs 2. Turn off the gas supply and ensure that the appliance is cold.
  • Page 15 © Baxi Heating U.K. Limited 2010. Installer Guide Fig. 26 7.0 Changing components on models without the Comfortstat control Burner 1. Undo the heat exchanger retaining nuts and washers and draw the casting forwards off the locating studs (Fig. 26).
  • Page 16 © Baxi Heating U.K. Limited 2010. Installer Guide 8.0 Changing components on Fig. 30 models with the Comfortstat control Changing Components 1. Before changing any components please read Section 1.3 Important Information. 2. Turn off the gas supply and ensure that the appliance is cold.
  • Page 17: Changing Components

    © Baxi Heating U.K. Limited 2010. Installer Guide Fig. 34 8.0 Changing components on models with the Comfortstat control Burner 1. Undo the heat exchanger retaining nuts and washers and draw the casting forward off the locating studs. Once clear of the studs the casting will need to be moved to the left to avoid the gas tap locating bracket.
  • Page 18: Fault Finding

    © Baxi Heating U.K. Limited 2010. Installer Guide Ensure all installation criteria have been satisfied before 8.0 Fault Finding performing Fault Finding (e.g. flue terminal position). 7±1.5mm Fig. 38 3.5±0.5mm...
  • Page 19: Short Parts List

    © Baxi Heating U.K. Limited 2010. Installer Guide 9.0 Short parts list Key G.C. Description Manufacturers No. No. Part No. Knob Control (F 5 / F 5S) G / R / S E26513 Grey 243262 205887 Beige 234637 Knob Control (F 8S)
  • Page 20: Owner Guide

    © Baxi Heating U.K. Limited 2010. Owner Guide. Baxi Brazilia F 5 Baxi Brazilia F 5S Baxi Brazilia F 8S Baxi Brazilia F 8ST Comfortstat 2...
  • Page 21: Warnings

    © Baxi Heating U.K. Limited 2010. Owner Guide 1.0 Warnings Safe Installation 1. The appliance is suitable for installation only in G.B. and I.E. and should be installed in accordance with the rules in force. For Ireland install in accordance with I.S.813 “Domestic gas installations”.
  • Page 22: Introduction & Operation

    Owner Guide 2.0 Introduction & Operation Introduction 1. Your Baxi Brazilia F is a room sealed gas convector heater. This means that the gas burning section is sealed from the room in which it is installed. It is connected to a circular flue terminal outside the building.
  • Page 23: Operating Units Fitted With The Comfortstat Control

    © Baxi Heating U.K. Limited 2010. Owner Guide 2.0 Introduction & Operation Operating units fitted with the Comfortstat control. 1. The appliance is controlled by two knobs which are positioned at the lower right on the front of case (Fig. 3).
  • Page 24: Cleaning & Clearances

    © Baxi Heating U.K. Limited 2010. Owner Guide 3.0 Cleaning & Clearances Cleaning the Appliance 1. When cold the appliance may be cleaned with a damp cloth and wiped with a soft duster. Do not use abrasive cleaning agents, wax or spray polish.
  • Page 25: Spares & Running Costs

    G.C. number. The G.C. number can be found on page 2 of these instructions. 3. A “Special Needs Adaptor” is available for use with the Baxi Brazilia F. This is designed for customers suffering from arthritis or similar conditions and provides the user with extra leverage when operating the control knob.
  • Page 26: Warranty & Service

    Proof of purchase (if you do not have the fire serial You must register your fire with heateam, the number) service division of Baxi Heating UK Limited, either by completing and returning the registration card or Note: details 1 – 4 should be recorded on page calling our free telephone registration line on 27 at the end of this guide.
  • Page 27 © Baxi Heating U.K. Limited 2010. Owner Guide The following pages are to be completed by the installer: Installer Details (Block Capitals) Installer Name Gas Safe Register or Corgi Registration Number. Company Name. Company Address Company Telephone number Company Fax number...
  • Page 28 © Baxi Heating U.K. Limited 2010. Baxi Heating U.K. Ltd manufacture a comprehensive range of products for the domestic heating market. Gas Central Heating Boilers (Wall, Floor and Fireside models). Independent Gas Fires. Renewal Firefronts. Gas Wall Heaters. Solid Fuel Fires.

This manual is also suitable for:

Brazilia f 8st comfortstat 2Brazilia f 5s

Table of Contents

Save PDF