17.0 
MINIMUM PLUMBING REQUIREMENTS 
 
This installation should be in accordance with BS 5449 code of practises. It must include a gravity circuit with an 
expansion tank open to the atmosphere. 
 
When installing this appliance on a gravity circuit, the system should consist of a tank/indirect cylinder fixed in 
an upright position and should be connected to the boiler by 28mm pipe both flow and return. The pipes 
should not exceed 7.8m in length. The shorter the run of pipe work the more effective the appliance is going to 
be at heating the water. The cylinder and pipe work should be lagged to minimise the heat loss in the system. A 
heat leak radiator must be incorporated into the system to dissipate any excess heat produced from the boiler 
when connected demands are low. The heat leak must comprise a minimum of 10% of the boiler output. Fit 
the heat leak radiator in the gravity circuit using 22mm pipe reducing 15mm for no more than 300mm before 
the radiator. 
 
18.0  BOILER CONNECTIONS 
 
The  Thermo  Verona  16  is  fitted  with  2  connections  for  piping.  These  connections  are  1    Inch  BSP  and  are  a 
female thread.  
19.0 
CHECKS ON INITIAL FIRING 
 
Before connecting up the boiler the installer must ensure that they thoroughly flush all of the systems pipes in 
order to remove any residue which could compromise the correct operation of all system components (Pumps, 
valves etc). It is also important to verify the chimney has sufficient draught, there are no blockages and that no 
other appliance exhausts are inserted into the flue. 
 
20.0 
FILLING UP THE SYSTEM 
 
ONCe all connections are complete the installer can proceed with the boiler connection. Open all the vent 
pipes of the radiators, the boiler and the system. Gradually open the load valve, ensuring that the air vent pipes 
are working correctly. Use the gauge to confirm the system is pressurised. With closed tank systems, a pressure 
of 0.11 – 0.12 MPa (1.1 – 1.2 bar) must be reached. 
 
21.0  CPS – CORROSION PREVENTION SYSTEM 
 
The CPS is a three‐way valve (regulated by temperature) that improves the efficiency of the boiler, reduces 
condensation and actively prolongs the longevity of the boiler. It does this by not allowing cold water from the 
heating system to be directly introduced into the boiler until a desired temperature is reached, in this case 
55°C. The CPS valve used is an ESBE VTC500 – we would recommend that this is installed if the system fitted is 
an open vented fully pumped system. 
 
 
   
 
                                                           
 
 
 
CPS Valve (ESBE VTC500) 
 
15
AB 
Return 
Flow
Pump 