TJERNLUND XCHANGER X2D Installation Instructions Manual

TJERNLUND XCHANGER X2D Installation Instructions Manual

Advertisement

Quick Links

REV. A 05/10
TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
TM
X
R
MODEL
CHANGE
X2D

INSTALLATION INSTRUCTIONS

OWNER'S INSTRUCTIONS, DO NOT DESTROY
THIS DEVICE MUST BE INSTALLED BY A
QUALIFIED PERSON.
READ INSTRUCTIONS CAREFULLY PRIOR TO
INSTALLATION AND OPERATION OF THE XCHANGER.
Copyright © 2010, Tjernlund Products, Inc. All rights reserved.
P/N 8504164

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XCHANGER X2D and is the answer not in the manual?

Questions and answers

Summary of Contents for TJERNLUND XCHANGER X2D

  • Page 1: Installation Instructions

    MODEL CHANGE INSTALLATION INSTRUCTIONS OWNER'S INSTRUCTIONS, DO NOT DESTROY THIS DEVICE MUST BE INSTALLED BY A QUALIFIED PERSON. READ INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION AND OPERATION OF THE XCHANGER. Copyright © 2010, Tjernlund Products, Inc. All rights reserved. P/N 8504164...
  • Page 2: Table Of Contents

    Tjernlund Products, Inc. CHANGE Tjernlund Products welcomes your comments and questions. Call us at (651) 426-2993, (800) 255-4208, Fax (651) 426-9547, email us at fanmail@tjfans.com or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN 55110-6794.
  • Page 3: Cautions

    CAUTIONS WARNING: Failure to install, maintain and/or operate the X in accordance with manufacturer’s instructions may result in CHANGE conditions that can produce bodily injury and property damage. Disconnect power supply to fans and/or control when reversing fan direction or servicing the X .
  • Page 4: Recommended Installation And Termination Locations

    XCHANGER OPERATION BASED ON AIR CHANGES PER HOUR This method of operation can be used to supplement or provide for guaranteed air change rates. Table 1 shows the constant Cubic Feet Per Minute (CFM) of air necessary to produce the desired Air Change Per Hour rate (ACH), assuming natural infiltration of out- side air at a rate of .10 ACH.
  • Page 5 DIAGRAM A INSTALLATION (TOOLS REQUIRED) • Reciprocating saw • 5/16” nut runner or socket • Siding tools (dependent on exterior finish) • Drill and 1/2” bit • Phillips screwdriver • Level INSTALLATION NOTE: Before cutting opening through wall, confirm X hood termination clearances are met as noted on bottom of page 3.
  • Page 6 4. Remove fans if necessary and insert X housing through exterior wall opening with fan openings facing down, CHANGE (See Diagram H). For vinyl or other types of lap siding, level X and trace outer flange on X housing and CHANGE CHANGE trim siding back enough to install J channel or appropriate flashing, (See Diagram E).
  • Page 7: Xchanger Tm Installation

    11. The damper stop prevents unwanted air infiltration through either fan. The Damper stop can be adjusted so the damper does not swing open into the house by wind or a negative pressure in the house. IMPORTANT: The damper stop prevents the damper from swinging inward and should not be used if using the X fan to bring outside air in.
  • Page 8: Xchanger Tm Ladder Diagram

    TJERNLUND LIMITED 1 YEAR WARRANTY Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1) year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc.