TJERNLUND DRYER DUCT BOOSTER LB2 Quick Start Manual

TJERNLUND DRYER DUCT BOOSTER LB2 Quick Start Manual

Advertisement

Quick Links

TJERNLUND PRODUCTS, INC.
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com
READ OWNERS INSTRUCTIONS CARE-
FULLY PRIOR TO INSTALLATION. SAVE
THESE INSTRUCTIONS.
IMPORTANTES POUR LA SÉCURITÉ.
CONSERVEZ CES INSTRUCTIONS.
The LB2 is Listed to the updated DEDPV, Dryer Exhaust Duct Power Ventilator supplement to UL705 & CSA C22.2 #113-12. The 2015
IRC restricts the use of dryer booster fans to those tested to the DEDPV supplement. Incorporating dryer booster fans in clothes dryer
ducts has increased substantially with the placement of laundry rooms not adjacent to outside walls. Duct runs often exceed 25 equiva-
lent feet (each elbow equates to five additional feet of duct length) that many manufacturers set as a maximum duct length. The LB2
booster fan is rated for duct lengths up to 150 equivalent feet.
MODEL LB2
Blower:
160 cfm
Motor:
115 Volts ~ 60 Hz
0.80 amps maximum
Impeller:
Reverse inclined, particulate handling
Components: (1) LB2 wired fan assembly
(1) Notification Panel
(1) 16 gauge galvanized steel mounting bracket
(1) mounting hardware packet
WARNING
!
This product has rotating parts, do not plug into power if duct is not connected on both ends of Dryer Duct Booster®.
The installation must comply with local electrical and mechanical, fuel gas, or building codes, and must be inspected and accepted by
local authorities having jurisdiction.
CAUTION: DO NOT INSTALL IN AN EXHAUST DUCTWORK OF A CLOTHES DRYER WHOSE INSTRUCTIONS PROHIBIT THE
INSTALLATION OF A CLOTHES DRYER BOOSTER FAN. ATTENTION: NE PAS INSTALLER DANS LE CONDUIT D'ÉVACUATION
DE LA SÉCHEUSE SI LES INSTRUCTIONS INTERDISENT L'INSTALLATION D'UN VENTILATEUR AUXILIAIRE.
CAUTION: DO NOT INSTALL IN AN EXHAUST DUCTWORK WHERE THE EQUIVALENT DUCT LENGTH IS LESS THAN OR
EQUAL TO 7.62 METERS (25 FT). ATTENTION: NE PAS INSTALLER DANS UN CONDUIT D'ÉVACUATION MESURANT 7,62
MÈTRES (25 PI) DE LONGUEUR OU MOINS.
The Dryer Booster Fan must be accessible after the installation is completed.
This Dryer Booster Fan may not be used in conjunction with dryers designated as high output.
WARNING - If a blinking or solid Red LED is displayed on the Notification Panel turn off clothes dryer and reference "Dryer Booster Fan
Notification Panel Status Lights" section of these instructions.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1) Your clothing dryer installation incorporates a dryer exhaust duct power ventilator (DEDPV) which may be in a different location than
your dryer, such as in an attic, crawl space or basement.
DRYER DUCT BOOSTER® FAN
DESCRIPTION & PURPOSE
SPECIFICATIONS & COMPONENTS
UL705
CSA C22.2 #113-12

INSTALLATION RESTRICTIONS

©2015 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED
MODEL LB2
FIGURE 8061040 1/19/15
For Residential Capacity Clothes Dryers
14"
4"
OUTLET
10.5"
INLET
6.25"
P/N: 8504216
10"
4"

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DRYER DUCT BOOSTER LB2 and is the answer not in the manual?

Questions and answers

Summary of Contents for TJERNLUND DRYER DUCT BOOSTER LB2

  • Page 1 1) Your clothing dryer installation incorporates a dryer exhaust duct power ventilator (DEDPV) which may be in a different location than your dryer, such as in an attic, crawl space or basement. ©2015 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED P/N: 8504216...
  • Page 2 2) Your clothing dryer depends on the DEDPV Booster Fan for its safe and efficient operation. Operating your dryer without a functional DEDPV will result in inefficient dryer operation, excess energy consumption and a possible fire hazard. See warnings on the Notification Panel.
  • Page 3 DIAGRAM C NOTE: Do not use screws in the dryer duct installation. The LB2 motor can be mounted in a horizontal or vertical orientation. Discharge must face up if mounted vertically, (See Diagram C). Do not install the LB2 in an orientation where the sensing tube port might fill with condensation, (See Diagram B).
  • Page 4 INSTALLING NOTIFICATION PANEL WITHOUT AN ELECTRICAL BOX 1. Cut opening in sheetrock 1-1/4” wide by 2-1/4” tall, hold Notification panel terminal block mounting plate over opening and mark top and bottom holes for wall anchors, (See Diagram H). Once marked, drill 3/16” holes for wall anchors and feed control cable through opening, (See Diagram I).
  • Page 5 If the dryer is operating and there is no Green LED on the Notification Panel, stop the dryer immediately and have the vent system inspected by someone qualified to do so. Contact Tjernlund at 1-800-255-4208 with further questions. (See LB2...
  • Page 6 If the dryer is operating and there is no Green LED on the Notification Panel, stop the dryer immediately and have the vent system inspected by someone qualified to do so. Contact Tjernlund at 1-800-255-4208 with further questions. PRESSURE FAULT MODE: (Red LED flashing) If at anytime during the calibration or operating cycle of the LB2 and the Dryer there is excessive positive pressure of +0.16”...
  • Page 7 TJERNLUND LIMITED FIVE YEAR MATERIAL AND NO-CLOG WARRANTY Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (5) years from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc.

Table of Contents

Save PDF