Output Function Summary Table – This table shows all functions for the logical outputs
(terminals [11], [12] and [AL]) at a glance. Detailed descriptions of these functions, related
parameters and settings, and example wiring diagrams are in "Using Intelligent Output
Terminals" in chapter 4.
Option
Code
00
01
02
03
04
05
06
07
09
10
11
12
13
19
20
21
CALL NOW 800-985-6929
http://www.automatedpt.com
Output Function Summary Table
Terminal
Function Name
Symbol
RUN
Run Signal
FA1
Frequency Arrival Type
1–Constant Speed
FA2
Frequency Arrival Type
2–Over frequency
OL
Overload Advance
Notice Signal 1
OD
Output Deviation for PID
Control
AL
Alarm Signal
FA3
Frequency Arrival Type
3–Set frequency
OTQ
Over/under Torque
Signal
UV
Undervoltage
TRQ
Torque Limited Signal
RNT
Run Time Expired
ONT
Power ON time Expired
THM
Thermal Warning
BRK
Brake Release Signal
BER
Brake Error Signal
ZS
Zero Hz Speed
Detection Signal
http://www.automatedpt.com
Description
ON
When the inverter is in Run Mode
OFF
When the inverter is in Stop Mode
ON
When output to motor is at the set frequency
OFF
When output to motor is OFF, or in any
acceleration or deceleration ramp
ON
When output to motor is at or above the set freq,
even if in accel (C042) or decel (C043) ramps
OFF
When output to motor is OFF, or at a level below
the set frequency
ON
When output current is more than the set
threshold (C041) for the overload signal
OFF
When output current is less than the set threshold
for the deviation signal
ON
When PID error is more than the set threshold for
the deviation signal
OFF
When PID error is less than the set threshold for
the deviation signal
ON
When an alarm signal has occurred and has not
been cleared
OFF
When no alarm has occurred since the last
cleaning of alarm(s)
ON
When output to motor is at the set frequency,
during accel (C042) and decel (C043).
OFF
When output to motor is OFF, or is not at a level of
the set frequency
ON
Estimated motor torque exceeds the specified
level
OFF
Estimated motor torque is lower than the specified
level
ON
Inverter is in Undervoltage
OFF
Inverter is not in Undervoltage
ON
Torque limit function is executing
OFF
Torque limit function is not executing
ON
Total running time of the inverter exceeds the
specified value
OFF
Total running time of the inverter does not exceed
the specified value
ON
Total power ON time of the inverter exceeds the
specified value
OFF
Total power ON time of the inverter does not
exceed the specified value
ON
Accumulated thermal count exceeds the C061 set
value
OFF
Accumulated thermal count does not exceed the
C061 set value
ON
Output for brake release
OFF
No action for brake
ON
Brake error has occurred
OFF
Brake performance is normal
ON
Output frequency falls below the threshold
specified in C063
75