Page 2
Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in speci- fications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not repre- sent a commitment on the part of HII.
Page 3
The user may find the fol- lowing booklet helpful: “Something About Interference.” This is available at FCC local regional offices. Honeywell is not responsible for any radio or television interference caused by unauthorized modifications of this equip- ment or the substitution or attachment of connecting cables and equipment other than those specified by Honeywell.
Page 4
Nijverheidsweg 9-13 5627 BT Eindhoven The Netherlands Honeywell shall not be liable for use of our product with equipment (i.e., power supplies, personal computers, etc.) that is not CE marked and does not comply with the Low Voltage Directive. Honeywell Scanning & Mobility Product...
Australia/NZ C-Tick Statement Conforms to AS/NZS 3548 Mexico Conforms to NOM-019. Russia Gost-R certificate South Korea This product meets Korean agency approval. Tawain BSMI Standard: CNS13438, CNS 14336 International Laser Safety Statement LASER LIGHT: DO NOT STARE INTO BEAM. CLASS 2 LASER PRODUCT. LASERSTRAHLUNG: NICHT IN DEN STRAHL BLICKEN.
Page 6
CB Scheme Certified to CB Scheme IEC60950-1, Second Edition. Solids and Water Protection The Voyager 1250g has a rating of IP42, immunity of foreign particles and drip- ping water. Patents For patent information, please refer to www.honeywellaidc.com/patents.
Page 7
Required Safety Label Locations Laser Output Laser Safety Part Number, information Serial Number Laser Label, and Revision Information location...
Table of Contents Chapter 1 - Getting Started About This Manual ............1-1 Unpacking Your Device..........1-1 Connecting the Device ..........1-1 Connecting with USB ..........1-1 Connecting with Keyboard Wedge ......1-2 Connecting with RS232 Serial Port ....... 1-3 Connecting with RS485.........
Page 11
Scanner-Bioptic Packet Mode ......2-34 ACK/NAK............. 2-34 Communication Timeout ........2-34 Chapter 3 - Input/Output Settings Power Up Beeper ............3-1 Beep on BEL Character ..........3-1 Good Read and Error Indicators ......... 3-2 Beeper – Good Read ..........3-2 Beeper Volume –...
Page 12
Deactivation Character ........3-15 Reread Delay.............3-16 User-Specified Reread Delay ........3-16 Output Sequence Overview........3-16 Output Sequence Editor ........3-16 To Add an Output Sequence ....... 3-17 Other Programming Selections......3-17 Output Sequence Editor ........3-19 Sequence Timeout..........3-19 Sequence Match Beeper ........3-20 Partial Sequence ..........
Page 13
Terminal ID Table............5-4 Data Format Editor Commands ........5-4 Move Commands ..........5-5 Search Commands..........5-6 Miscellaneous Commands ........5-7 Data Formatter ............5-8 Data Format Non-Match Error Tone...... 5-9 Primary/Alternate Data Formats........ 5-10 Single Scan Data Format Change....... 5-10 Chapter 6 - Symbologies All Symbologies............
Page 14
EAN-13 Beginning with 290 Addenda Required .. 6-46 EAN-13 Beginning with 378/379 Addenda Required ......... 6-47 EAN-13 Beginning with 414/419 Addenda Required ......... 6-48 EAN-13 Beginning with 434/439 Addenda Required ......... 6-48 EAN-13 Beginning with 977 Addenda Required .. 6-49 EAN-13 Beginning with 978 Addenda Required ..
Page 15
Read Time-Out............9-4 Resetting the Standard Product Defaults ....9-4 Menu Commands ............9-6 Chapter 10 - Product Specifications Voyager 1250g Scanner Product Specifications ..10-1 Depth of Field ............10-2 Typical Performance ........... 10-2 Standard Cable Pinouts ..........10-3 Keyboard Wedge..........
Voyager 1250g single-line laser scanner. Product specifications, dimensions, warranty, and customer support information are also included. Honeywell bar code scanners are factory programmed for the most common terminal and communications settings. If you need to change these settings, programming is accomplished by scanning the bar codes in this guide.
The scanner beeps. Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual. The unit defaults to a USB PC Keyboard. Refer to page 2-5 for other USB terminal settings. For additional USB programming and technical information, refer to “USB Application Note,”...
Connecting with RS232 Serial Port Turn off power to the terminal/computer. Connect the appropriate interface cable to the scanner. only if power supply is included Plug the serial connector into the serial port on your computer. Tighten the two screws to secure the connector to the port. Once the scanner has been fully connected, power up the computer.
Connecting with RS485 A scanner can be connected for an IBM POS terminal interface. Connect the appropriate interface cable to the device, then to the com- puter. Turn the terminal/computer power back on. The scanner beeps. Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual.
15° to 18° to prevent unwanted reflection. Menu Bar Code Security Settings Honeywell scanners are programmed by scanning menu bar codes or by send- ing serial commands to the scanner. If you want to restrict the ability to scan menu codes, you can use the Menu Bar Code Security settings.
When you have entered all the commands you want to save for your custom defaults, scan the Save Custom Defaults bar code. Set Custom Defaults Save Custom Defaults You may have a series of custom settings and want to correct a single setting. To do so, just scan the new setting to overwrite the old one.
Programming the Interface Introduction This chapter describes how to program your system for the desired interface. Programming the Interface - Plug and Play Plug and Play bar codes provide instant scanner set up for commonly used interfaces. Note: After you scan one of the codes, power cycle the host terminal to have the interface in effect.
RS232 Interface RS485 Scan one of the following “Plug and Play” codes to program the scanner for an IBM POS terminal interface. Note: After scanning one of these codes, you must power cycle the cash register. IBM Port 5B Interface IBM Port 9B HHBCR-1 Interface IBM Port 17 Interface...
OPOS Mode The following bar code configures your scanner for OPOS (OLE for Retail Point of Sale) by modifying the following OPOS-related settings: Option Setting Interface RS232 Baud Rate 38400 RS232 Flow Control, No Timeout Handshaking XON/XOFF Off ACK/NAK Off Data Bits, Stop 8 Data, 1 Stop, Parity None Bits, and Parity...
USB IBM SurePos Scan one of the following “Plug and Play” codes to program the scanner for an IBM SurePos (USB handheld scanner) or IBM SurePos (USB tabletop scanner) interface. Note: After scanning one of these codes, you must power cycle the cash register.
USB PC or Macintosh Keyboard Scan one of the following codes to program the scanner for USB PC Key- board or USB Macintosh Keyboard. Scanning these codes also adds a CR and LF. USB Keyboard (Mac) USB Japanese Keyboard (PC) USB HID Scan the following code to program the scanner for USB HID bar code scanners.
Scan one of the following codes to program the scanner to emulate a regu- lar RS232-based COM Port. If you are using a Microsoft® Windows® PC, you will need to download a driver from the Honeywell website (www.honeywellaidc.com). The driver will use the next available COM Port number.
ACK/NAK Mode ACK/NAK Mode On * ACK/NAK Mode Off Communication Timeout This allows you to set the length (in milliseconds) for a timeout for the host ACK/NAK response. Scan the bar code below, then set the timeout (from 0-65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save.
Communication Timeout Beeper This selection programs the scanner to issue an error beep when a communication timeout has occurred. The error beep sound is pro- grammed using Number of Beeps – Error (page 3-4). Default = On. * On NAK Retries This selection limits the number of NAK retries that can occur in ACK/NAK mode.
® Verifone Ruby Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Verifone Ruby terminal. This bar code sets the baud rate to 1200 bps and the data for- mat to 8 data bits, Mark parity, 1 stop bit and RTS/CTS no timeout. It also adds a line feed (LF) suffix and programs the following prefixes for each symbology: Symbology Prefix...
Honeywell Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration. This bar code sets the baud rate to 38400 bps and the data format to 8 data bits, no parity, 1 stop bit. Character RTS/CTS with timeout and 232 ACK/NAK are also enabled.
NCR Bioptic Settings Note: If you are having unexpected results with this programming code, scan the Activate Defaults bar code on page 8-4 first, then scan the programming bar code above. Wincor Nixdorf Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nix- dorf terminal.
Wincor Nixdorf Beetle™ Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nix- dorf Beetle terminal. The following prefixes are programmed for each symbol- ogy: Symbology Prefix Symbology Prefix Code 128 EAN-13 Code 93 GS1-128 Codabar...
Wincor Nixdorf RS232 Mode A Scan the following Plug and Play code to program the scanner for a Wincor Nix- dorf RS232 Mode A terminal. The following prefixes are programmed for each symbology: Symbology Prefix Symbology Prefix Code 128 EAN-13 Code 93 GS1-128 Codabar...
Keyboard Country Layout Scan the appropriate country code below to program the keyboard layout for your country or language. As a general rule, the following characters are sup- ported, but need special care for countries other than the United States: @ | $ # { } [ ] = / ‘...
Page 37
Keyboard Country (continued) Canada (French legacy) Canada (French) Canada (Multilingual) China Croatia Czech Czech (Programmers) Czech (QWERTY) Czech (QWERTZ) Denmark Dutch (Netherlands) Estonia Faeroese 2 - 15...
Page 39
Keyboard Country (continued) Hungary Iceland Ireland Italian (142) Italy Japan ASCII Kazakh Korea Kyrgyz (Cyrillic) Latin America Latvia Latvia (QWERTY) Lithuania Lithuania (IBM) 2 - 17...
Page 40
Keyboard Country (continued) Macedonia Malta Mongolian (Cyrillic) Norway Poland Polish (214) Polish (Programmers) Portugal Romania Russia Russian (MS) Russian (Typewriter) 2 - 18...
Page 41
Keyboard Country (continued) Serbia (Cyrillic) Serbia (Latin) Slovakia Slovakia (QWERTY) Slovakia (QWERTZ) Slovenia Spain Spanish variation Sweden Switzerland (French) Switzerland (German) Tatar Thailand 2 - 19...
Keyboard Country (continued) Turkey F Turkey Q Ukrainian United Kingdom United Stated (Dvorak right) United States (Dvorak left) United States (Dvorak) United States (International) Uzbek (Cyrillic) Vietnam Keyboard Wedge Modifiers ALT Mode If your bar code contains special characters from the extended ASCII chart for example, an e with an accent grave (è), you will use ALT Mode.
If your keystrokes require using the ALT key and 3 characters, scan the 3 Characters bar code. If your keystrokes require the ALT key and 4 charac- ters, scan the 4 Characters bar code. The data is then output with the spe- cial character(s).
Autocaps via NumLock bar code should be scanned in countries (e.g., Germany, France) where the Caps Lock key cannot be used to toggle Caps Lock. The NumLock option works similarly to the regular Autocaps, but uses the NumLock key to retrieve the current state of the Caps Lock. Autocaps via NumLock Emulate External Keyboard should be scanned if you do not have an external keyboard (IBM AT or equivalent).
Control + ASCII Mode On: The scanner sends key combinations for ASCII control characters for values 00-1F (refer to the ASCII Conversion Chart (Code Page 1252), page A-3). Windows is the preferred mode. All key- board country codes are supported. DOS mode is a legacy mode, and it does not support all keyboard country codes.
between scan codes. Set the length (in milliseconds) for a delay by scan- ning the bar code below, then setting the delay (from 1-30) by scanning dig- its from the Programming Chart, then scanning Save. Default = 0 (800 µs). Inter-Scan Code Delay <F0>...
RS232 Modifiers RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate. The host terminal must be set for the same baud rate as the scanner. Default = 9600. 1200 2400 4800 * 9600 19200 38400...
RS232 Word Length: Data Bits, Stop Bits, and Parity Data Bits sets the word length at 7 or 8 bits of data per character. If an application requires only ASCII Hex characters 0 through 7F decimal (text, digits, and punctuation), select 7 data bits. For applications that require use of the full ASCII set, select 8 data bits per character.
7 Data, 2 Stop, Parity Space 8 Data, 1 Stop, Parity Space 7 Data, 1 Stop, Parity Mark 7 Data, 2 Stop, Parity Mark 8 Data, 1 Stop Parity Mark RS232 Handshaking RS232 Handshaking allows control of data transmission from the scanner using software commands from the host device.
and CTS is not asserted, the device transmit buffer is cleared and scanning may resume. Default = RTS/CTS Off. Flow Control, No Timeout Character-Based Flow Control, No Timeout Two-Direction Flow Control Flow Control with Timeout Character-Based Flow Control with Timeout * RTS/CTS Off RS232 Timeout When using Flow Control with Timeout, you must program the length of the...
data transmission stops. To resume transmission, the host sends the XON character (DC1, hex 11). Data transmission continues where it left off when XOFF was sent. Default = XON/XOFF Off. XON/XOFF On * XON/XOFF Off ACK/NAK After transmitting data, the scanner waits for an ACK character (hex 06) or a NAK character (hex 15) response from the host.
number of retries (from 0-255) by scanning digits from the Programming Chart, then scanning Save. (5 is the recommended set- ting.) Default = 0. Timeout Retries Communication Timeout Beeper This selection programs the scanner to issue an error beep when a communication timeout has occurred.
Support BEL/CAN in ACK/NAK This protocol responds to <BEL> and <CAN> commands when in ACK/ NAK mode. The scanner sounds an error tone when a <BEL> command is sent from the host. <CAN> terminates the transmission. Default = BEL/ CAN Off. BEL/CAN On * BEL/CAN Off RS232 Defaults...
Block Check Character When this selection is set to Transmit, the NCR Block Check Character (BCC) is expected with incoming messages and transmitted with outgoing messages. Default = Transmit. * Transmit Don’t Transmit NCR Prefix This selection allows you to program an NCR-specific prefix. Refer to the ASCII Conversion Chart (Code Page 1252) on page A-3 to find the hex equivalent for the characters you want for the NCR prefix (typically, 02 for...
When set to Off, no sound is emitted for an NOF. Default = Off. * Off Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners. Note: The scanner’s baud rate must be set to 38400 and the RS232 Timeout must be set to 3000 in order to communicate with a bioptic scanner.
Scanner-Bioptic Packet Mode Packet Mode On must be scanned to set the scanner’s format so it is com- patible with a bioptic scanner. Default = Packet Mode Off. * Packet Mode Off Packet Mode On ACK/NAK After transmitting data, the scanner waits for an ACK character (hex 06) or a NAK character (hex 15) response from the host.
Input/Output Settings Power Up Beeper The scanner can be programmed to beep when it’s powered up. Scan the Off bar code(s) if you don’t want a power up beep. Default = Power Up Beeper On - Scanner. Power Up Beeper Off - Scanner * Power Up Beeper On - Scanner...
Good Read and Error Indicators Beeper – Good Read The beeper may be programmed On or Off in response to a good read. Turning this option off, only turns off the beeper response to a good read indication. All error and menu beeps are still audible. Default = Beeper - Good Read On.
Beeper Pitch – Good Read The beeper pitch codes modify the pitch (frequency) of the beep the scan- ner emits on a good read. Default = Medium. Low (1600 Hz) * Medium (2350 Hz) High (4200 Hz) Beeper - Transmit Order The beeper transmit order determines when the good read beep occurs.
Beeper Duration – Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read. Default = Normal. * Normal Beep Short Beep Short Beep Number of Beeps – Good Read The number of beeps of a good read can be programmed from 1 - 9. The same number of beeps will be applied to the beeper and LED in response to a good read.
Page 61
To change the number of error beeps, scan the bar code below and then scan a digit (1-9) bar code and the Save bar code on the Programming Chart inside the back cover of this manual. Default = 1. Number of Error Beeps/LED Flashes 3 - 5...
LED Indicators The green and red LEDs can be programmed to be On or Off and at different brightness levels to indicate various scanner states. Use the following bar codes to program the LED indicators. LED Settings Default = Red LED Off with Laser, Green LED On with Good Scan. * Red LED Off Green LED Off Red LED On with Good Scan...
Red LED On with CTS Green LED On with CTS LED Brightness Default = Red High, Green High. Red Off Green Off Red Low Green Low Red Medium Green Medium * Red High * Green High In-Stand and Out-Of-Stand Settings The following settings program the scanner’s behavior when it is either in the stand, or out of the stand (hand-held).
Caution: When working with In-Stand and Out-of-Stand settings, enable the settings you want before disabling those you do not want to use. If you disable settings first, you may program the scanner so it is unable to read bar codes. if this happens, power cycle the scanner and scan the defaults bar code on page 1-6.
Presentation Mode with CodeGate® Out-of-Stand: When the scanner is not in the stand, it automatically detects bar codes and decodes them. However, the data is not transmitted until you pull the trigger. The laser remains on briefly after the transmission. (If you are accustomed to a Voy- ager 9540, this setting is the same as the 9540’s default.) Presentation Mode Out-of-Stand...
good read. If you scan Do Not End Manual Activation After Good Read, the laser remains on after a good read, but the trigger must be pressed to scan the next bar code. Default = End Manual Activation After Good Read. Do Not End Manual Activation After Good Read In-Stand * End Manual Activation After...
® CodeGate When CodeGate is On, the trigger is used to allow decoded data to be transmitted to the host system. The scanner remains on, scanning and decoding bar codes, but the bar code data is not transmitted until the trig- ger is pressed.
End Object Detection After Good Read After a bar code is successfully detected and read from the scanner, the laser can be programmed either to remain on and scanning, or to turn off. When End Object Detection After Good Read is enabled, the laser turns off and stops scanning after a good read.
Object Detection Distance When the scanner is in the stand and you are using Object Detection Mode, you can set the distance range for detecting objects. Short sets the scanner to detect objects approximately 5 inches (12.7cm) away from the nose.
to read the alphanumeric combination that represents that ASCII character. Scan Save to finish. Activation Character End Character Activation After Good Read After a bar code is successfully detected and read from the scanner, the laser can be programmed either to remain on and scanning, or to turn off. When End Character Activation After Good Read is enabled, the laser turns off and stops scanning after a good read.
Character Deactivation Mode If you have sent a character from the host to trigger the scanner to begin scan- ning, you can also send a deactivation character to stop scanning. Scan the On bar code below to use character deactivation, then use Deactivation Character (following) to select the character you will send from the host to terminate scan- ning.
Reread Delay This sets the time period before the scanner can read the same bar code a sec- ond time. Setting a reread delay protects against accidental rereads of the same bar code. Longer delays are effective in minimizing accidental rereads. Use shorter delays in applications where repetitive bar code scanning is required.
the Universal values, shown below. These are the defaults. Be certain you want to delete or clear all formats before you read the Default Sequence symbol. Note: If CodeGate is enabled, you must hold the trigger while reading each bar code in a sequence. Note: To make Output Sequence Editor selections, you’ll need to know the code I.D., code length, and character match(es) your application requires.
Output Sequence Example In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below. Note: Code 93 must be enabled to use this example. A - Code 39 B - Code 128 C - Code 93...
SEQBLKsequence editor start command code identifier for Code 39 0012 A - Code 39 sample length (11) plus CR suffix (1) = 12 start character match for Code 39, 41h = “A” termination string for first code code identifier for Code 128 0013 B - Code 128 sample length (12) plus CR suffix (1) = 13 start character match for Code 128, 42h = “B”...
Sequence Match Beeper By default, the scanner beeps when a sequence match is found. If you want the scanner to remain silent, scan the Sequence Match Beeper Off bar code below. Default = Sequence Match Beeper On. Sequence Match Beeper Off * Sequence Match Beeper On Partial Sequence If an output sequence operation is terminated before all your output...
When the output sequence is Off, the bar code data is output to the host as the scanner decodes it. Default = Off. Required On/Not Required *Off No Read With No Read turned On, the scanner notifies you if a code cannot be read. If using an EZConfig-Scanning Tool Scan Data Window (see page 8-2), an “NR”...
Data Editing Prefix/Suffix Overview When a bar code is scanned, additional information is sent to the host computer along with the bar code data. This group of bar code data and additional, user-defined data is called a “message string.” The selections in this section are used to build the user-defined data into the message string.
symbology to which you want to apply the prefix or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”. Step 3. Scan the 2 hex digits from the Programming Chart inside the back cover of this manual or scan 9, 9 for all symbologies. Step 4.
Step 1. Scan the Clear One Prefix or Clear One Suffix symbol. Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in the Symbology Charts, beginning on page A-1) for the symbology from which you want to clear the prefix or suffix. Step 3.
Suffix Selections Add Suffix Clear One Suffix Clear All Suffixes Transmit Alternate Extended ASCII Characters You may need to emulate special keyboard functions, such as up or down arrows, Alt/Make or Alt/Break commands, that are not supported in the Extended ASCII Character table. Refer to Alternate Extended ASCII Characters (page 4-5) for a range of keyboard function keys and corresponding...
Page 83
Alternate Extended ASCII Characters DEC HEX Keyboard Function DEC HEX Keyboard Function ↑ 128 80 152 98 up arrow ↓ 129 81 153 99 down arrow → 130 82 154 9A right arrow ← 131 83 155 9B left arrow 132 84 Insert 156 9C Numeric Keypad +...
Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in Supported Interface Keys starting on page 7-2.
Intercharacter, Interfunction, and Intermessage Delays Some terminals drop information (characters) if data comes through too quickly. Intercharacter, interfunction, and intermessage delays slow the transmission of data, increasing data integrity. Intercharacter Delay An intercharacter delay of up to 5000 milliseconds (in 5ms increments) may be placed between the transmission of each character of scanned data.
Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value for the ASCII character that will trigger the delay ASCII Conversion Chart (Code Page 1252) on page A-3. Delay Length Character to Trigger Delay To remove this delay, scan the Delay Length bar code, and set the number of delays to 0.
Intermessage Delay An intermessage delay of up to 5000 milliseconds (in 5ms increments) may be placed between each scan transmission. Scan the Intermessage Delay bar code below, then scan the number of 5ms delays, and the Save bar code using the Programming Chart inside the back cover of this man- ual.
Data Formatting Data Format Editor Introduction You may use the Data Format Editor to change the scanner’s output. For exam- ple, you can use the Data Format Editor to insert characters at certain points in bar code data as it is scanned. The selections in the following pages are used only if you wish to alter the output.
Page 90
you are programming. (See Primary/Alternate Data Formats on page 5-10 for further information.) Step 3. Terminal Type Refer to Terminal ID Table (page 5-4) and locate the Terminal ID number for your PC. Scan three numeric bar codes on the Programming Chart to program the scanner for your terminal ID (you must enter 3 digits).
Other Programming Selections Clear One Data Format This deletes one data format for one symbology. If you are clearing the primary format, scan 0 from the Programming Chart inside the back cover of this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending on the format you are clearing.
Terminal ID Table Terminal Terminal Model(s) PC/AT and compatibles PS2 Keyboard USB SurePOS Handheld Scanner USB SurePOS Tabletop Scanner RS232 True RS485 Serial PC Keyboard Mac Keyboard Japanese Keyboard (PC) HID POS Data Format Editor Commands Send Commands Send all characters F1 Include in the output message all of the characters from the input message, starting from current cursor position, followed by an insert character.
A-3 for decimal, hex and character codes. Insert symbology name B3 Insert the name of the bar code’s symbology in the output message, without moving the cursor. Only symbologies with a Honeywell ID are included (see Symbology Charts on page A-1).
Move the cursor to the beginning F7 Move the cursor to the first character in the input message. Syntax = Move the cursor to the end EA Move the cursor to the last character in the input message. Syntax = Search Commands Search forward for a character F8 Search the input message forward for “xx”...
Search forward for a non-matching character E6 Search the input message forward for the first non-“xx” character from the current cursor position, leaving the cursor pointing to the non-“xx” character. Syntax = E6xx where xx stands for the search character’s hex value for its ASCII code.
Compare characters FE Compare the character in the current cursor position to the character “xx.” If characters are equal, move the cursor forward one position. Syntax = FExx where xx stands for the comparison character’s hex value for its ASCII code. Refer to the ASCII Conversion Chart (Code Page 1252) on page A-3...
Data Formatter On, Not Required, Drop Prefix/Suffix Scanned data is modified according to your data format. If a data format is found for a particular symbol, those prefixes and suffixes are not transmitted. Data Format Required, Keep Prefix/Suffix Scanned data is modified according to your data format, and prefixes and suffixes are transmitted.
will sound. If you wish to hear the error tone when a non-matching bar code is found, scan the Data Format Non-Match Error Tone On bar code. Default = Data Format Non-Match Error Tone On. * Data Format Non-Match Error Tone On Data Format Non-Match Error Tone Off...
Page 99
For example, you may have set your device to the data format you saved as Data Format 3. You can switch to Data Format 1 for a single trigger pull by scanning the Single Scan-Data Format 1 bar code below. The next bar code that is scanned uses Data Format 1, then reverts back to Data Format Single Scan-Primary Data Format...
Symbologies This programming section contains the following menu selections. Refer to Chapter 9 for settings and defaults. • All Symbologies • GS1-128 • Airline Code 5 - see Straight 2 of 5 • Interleaved 2 of 5 IATA (two-bar start/stop) •...
Message Length Description You are able to set the valid reading length of some of the bar code symbolo- gies. If the data length of the scanned bar code doesn’t match the valid read- ing length, the scanner will issue an error tone. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data.
Codabar <Default All Codabar Settings> Codabar On/Off * On Codabar Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit. Transmit * Don’t Transmit Codabar Check Character Codabar check characters are created using different “modulos.”...
When Check Character is set to Validate, but Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. * No Check Character Validate Modulo 16, but Don’t Transmit Validate Modulo 16 and Transmit...
Page 105
Select Require to prevent the scanner from decoding a single “D” Codabar symbol without its companion. This selection has no effect on Codabar symbols without Stop/Start D characters. * Off Require Concatenation Timeout When searching for bar codes during concatenation, you may wish to set a delay used to find the next bar code.
Codabar Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80. Minimum Message Length Maximum Message Length 6 - 6...
Code 39 < Default All Code 39 Settings > Code 39 On/Off * On Code 39 Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.
When Check Character is set to Validate and Transmit, the scanner only reads Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Charac- ter. * No Check Character Validate, but Don’t Transmit Validate and Transmit...
Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital- ian pharmacies. This symbology is also known as PARAF. * Off Full ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar code symbol will be interpreted as a single character.
Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9. Full ASCII On * Full ASCII Off Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > Interleaved 2 of 5 On/Off * On NULL Characters...
Check Digit No Check Digit indicates that the scanner reads and transmits bar code data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data.
Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 6, Maximum Default = 80. Minimum Message Length Maximum Message Length NEC 2 of 5...
Page 113
When Check Digit is set to Validate and Transmit, the scanner only reads NEC 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data. Default = No Check Digit. * No Check Digit Validate, but Don’t Transmit Validate and Transmit...
Code 93 < Default All Code 93 Settings > Code 93 On/Off * On Code 93 Redundancy If you are encountering errors when reading Code 93 bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
Code 93 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80. Minimum Message Length Maximum Message Length Straight 2 of 5 Industrial (three-bar start/stop) <Default All Straight 2 of 5 Industrial Settings>...
scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0. Straight 2 of 5 Industrial Redundancy Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length.
Straight 2 of 5 IATA (two-bar start/stop) Note: This symbology is also known as Airline Code 5. <Default All Straight 2 of 5 IATA Settings> Straight 2 of 5 IATA On/Off * Off Straight 2 of 5 IATA Redundancy If you are encountering errors when reading Straight 2 of 5 IATA bar codes, you may want to adjust the redundancy count.
Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 13, Maximum Default = 15. Minimum Message Length Maximum Message Length Matrix 2 of 5...
When Check Character is set to Validate and Transmit, the scanner only reads Matrix 2 of 5 bar codes printed with a check character, and will trans- mit this character at the end of the scanned data. Default = No Check Character.
Code 11 <Default All Code 11 Settings> Code 11 On/Off * Off Check Digits Required These options set whether 1 or 2 check digits are required with Code 11 bar codes. Auto Select Check Digits determines the number of check digits based on the length of the bar code.
Page 121
Check Digit Validation When Check Character is set to Validate and Transmit, the scanner will only read Code 11 bar codes printed with the specified type check charac- ter(s), and will transmit the character(s) at the end of the scanned data. Validate and Transmit One Check Digit Validate and Transmit Two...
Code 11 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80. Minimum Message Length Maximum Message Length 6 - 22...
Code 128 <Default All Code 128 Settings> Code 128 On/Off * On 128 Group Separator Output If you wish to transmit the group separator characters “GS” (0x1D hex) with your Code 128 bar code output, scan the On bar code. When Off is scanned, the group separator is not output.
128 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0. Code 128 Redundancy Code 128 Message Length Scan the bar codes below to change the message length.
Page 125
Concatenation Timeout When searching for bar codes during concatenation, you may wish to set a delay used to find the next bar code. Set the length (in milliseconds) for this delay by scanning the bar code below, then setting the timeout (from 1- 65535 milliseconds) by scanning digits from the Programming Chart, then...
Page 126
ISBT 128 Predefined Concatenation Sequences On/ The following selections allow you to enable or require the Predefined ISBT 128 Concatenation Sequences. If you scan Off, the predefined concatenation sequences are disabled. If you scan the Allow Predefined Sequence code, then the scanner will output only the data combination specified in the predefined concatenation sequence you selected.
Page 127
Step 1. Scan the 1st Left Identifier bar code, below. Step 2. Use the Programming Chart to scan 3, D (hex for “=”). Step 3. Scan Save. Step 4. Scan the 2nd Left Identifier bar code, below. Step 5. Use the Programming Chart to scan 4, 7 (hex for “G”).
Page 128
If you scan the Require User-Defined Sequence code, the data combina- tion specified in the User-Defined concatenation sequence is required to transmit the data. No data is output unless the sequence is read. Default = Off. * Off Allow User-Defined Sequence Require User-Defined Sequence Content Verification When the On bar code is scanned, the check character values are output...
Page 129
tion Identification Number identifiers, only the first ID character is removed from the Donation Identification Number. The second character is transmit- ted as normal data. Default = On. * On Flag Digit Conversion Type 3 flag digits are a part of the Donation Identification Number in an ISBT 128 bar code.
GS1-128 <Default All GS1-128 Settings> GS1-128 On/Off * On GS1-128 Application Identifier Parsing This allows a single GS1-128 bar code to be broken into multiple transmis- sions based on the presence of application identifiers (AI) embedded in the bar code. Scan Transmit Without Identifiers if you want the bar code broken into packets and stripped of the AI.
Page 131
128 Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0. GS1-128 Redundancy GS1-128 Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information.
Telepen <Default All Telepen Settings> Telepen On/Off * Off Telepen Output Using AIM Telepen Output, the scanner reads symbols with start/stop pat- tern 1 and decodes them as standard full ASCII (start/stop pattern 1). When Original Telepen Output is selected, the scanner reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2).
Telepen Redundancy bar code below, then scan a redundancy count between 0 and 10 on the Programming Chart inside the back cover of this manual. Then scan the Save bar code. Default = 0. Telepen Redundancy Telepen Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information.
Page 134
UPC-A Number System and Check Digit UPC-A sample showing the number system and check digit: Number Check System Digit UPC-A Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the can be programmed so it will not transmit it.
Page 135
UPC-A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-A Addenda Required When Required is scanned, the scanner will only read UPC-A bar codes...
timeout by scanning the bar code below, then setting the timeout (from 0- 65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100. Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
If you scan the Allow Concatenation code, when the scanner sees the coupon code and the extended coupon code in a single scan, it transmits both as sepa- rate symbologies. Otherwise, it transmits the first coupon code it reads. If you scan the Require Concatenation code, the scanner must see and read the coupon code and extended coupon code in a single read to transmit the data.
UPC-A Number System 5 Addenda Required This setting programs the scanner to require any combination of a coupon code, a 2 digit addenda, or a 5 digit addenda on UPC-A bar codes that begin with a “5.” The following settings can be programmed: Require Coupon Code/Addenda: All UPC-A bar codes that begin with a “5”...
Addenda Timeout You can set a time during which the scanner looks for a coupon code. If a coupon code is not found within this time period, the data can be either transmitted or discarded, based on the setting you are using for UPC-A/ EAN-13 with Extended Coupon Code UPC-A Number System 4...
Page 140
UPC-E0 Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. * Off UPC-E0 Number System The numeric system digit of a UPC-A symbol is normally transmitted at the beginning of scanned data. When using UPC-E Expand, the unit can be programmed so it will not transmit it.
Page 141
UPC-E0 Number System and Check Digit UPC-E0 sample showing the number system and check digit: Number Check System Digit UPC-E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = Off. * Off UPC-E0 Leading Zero This feature allows the transmission of a leading zero (0) at the beginning...
Page 142
UPC-E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-E data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off UPC-E0 Addenda Required When Required is scanned, the scanner will only read UPC-E bar codes...
Page 143
timeout by scanning the bar code below, then setting the timeout (from 0- 65535 milliseconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100. Note: The Addenda Timeout setting is applied to all addenda and coupon code searches.
EAN/JAN-13 <Default All EAN/JAN Settings> EAN/JAN-13 On/Off * On Convert UPC-A to EAN-13 When UPC-A Converted to EAN-13 is selected, UPC-A bar codes are converted to 13 digit EAN-13 codes by adding a zero to the front. When Do not Convert UPC-A is selected, UPC-A codes are read as UPC-A. UPC-A Converted to EAN-13 * Do Not Convert UPC-A 6 - 44...
Page 145
EAN/JAN-13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On EAN/JAN-13 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data.
EAN-13 Beginning with 2 Addenda Required This setting programs the scanner to require a 2 digit addenda only on EAN-13 bar codes that begin with a “2.” The following settings can be pro- grammed: Require 2 Digit Addenda: All EAN-13 bar codes that begin with a “2” must have a 2 digit addendum.
Default = Don’t Require 5 Digit Addenda. 5 Digit * Don’t Require Addenda 5 Digit Addenda Require EAN-13 Beginning with 378/379 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “378” or “379.”...
EAN-13 Beginning with 414/419 Addenda Required This setting programs the scanner to require any combination of a 2 digit addenda or a 5 digit addenda on EAN-13 bar codes that begin with a “414” or “419.” The following settings can be programmed: Require Addenda: All EAN-13 bar codes that begin with a “414”...
Default = Don’t Require Addenda. * Don’t Require Addenda Require 2 Digit Addenda Require 5 Digit Addenda Require 2 or 5 Digit Addenda EAN-13 Beginning with 977 Addenda Required This setting programs the scanner to require a 2 digit addenda only on EAN-13 bar codes that begin with “977.”...
Require 5 Digit Addenda: All EAN-13 bar codes that begin with “978” must have a 5 digit addendum. The EAN-13 bar code with the 5 digit addendum is then transmitted as a single, concatenated bar code. If a 5 digit addendum is not found within the Addenda Timeout period, the EAN- 13 bar code is discarded.
Page 151
Addenda Timeout You can set a time during which the scanner looks for an addenda. If an addenda is not found within this time period, the data can be either trans- mitted or discarded, based on the setting you are using for EAN/JAN-13 Addenda Required.
ISBN Translate ISBNs are printed on books using the EAN-13 bar code symbology. To translate EAN-13 Bookland symbols into their equivalent ISBN number for- mat, scan the On bar code below. Default = Off. * Off Convert ISBN to 13-Digit When translating EAN-13 codes to the ISBN format, you can convert the bar code to a 13 digit format by scanning the Convert to 13-Digit On bar code below.
ISSN Translate When On is scanned, EAN-13 977 Bookland symbols are translated into their equivalent 8-digit ISSN number format. For example, 9770123456787 will be transmitted as 01234560. Default = Off. * Off ISSN Reformat When Reformat On is scanned, EAN-13 977 Bookland symbols are translated into their equivalent 8-digit ISSN number format, with hyphens added to the output.
EAN/JAN-8 <Default All EAN/JAN-8 Settings> EAN/JAN-8 On/Off * On EAN/JAN-8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. * On 6 - 54...
Page 155
EAN/JAN-8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-8 data. Default = Off for both 2 Digit and 5 Digit Addenda. 2 Digit Addenda On * 2 Digit Addenda Off 5 Digit Addenda On * 5 Digit Addenda Off EAN/JAN-8 Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 bar...
Page 156
scanning the bar code below, then setting the timeout (from 0-65535 milli- seconds) by scanning digits from the Programming Chart, then scanning Save. Default = 100. Note: The Addenda Timeout setting is applied to all addenda and coupon code searches. Addenda Timeout EAN/JAN-8 Addenda Separator When this feature is On, there is a space between the data from the bar...
<Default All MSI Settings> MSI On/Off * Off MSI Check Character Different types of check characters are used with MSI bar codes. You can program the scanner to read MSI bar codes with Type 10 check charac- ters. Default = Validate Type 10, but Don’t Transmit. When Check Character is set to Validate Type 10/11 and Transmit, the scanner will only read MSI bar codes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned...
Page 158
When Check Character is set to Validate Type 10/11, but Don’t Transmit, the unit will only read MSI bar codes printed with the specified type check character(s), but will not transmit the check character(s) with the scanned data. * Validate Type 10, but Don’t Transmit Validate Type 10 and Transmit Validate 2 Type 10 Characters,...
MSI Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80. Minimum Message Length Maximum Message Length Plessey Code <...
When Check Character is set to Validate and Transmit, the scanner only reads Plessey bar codes printed with a check character, and will transmit this character at the end of the scanned data. Default = No Check Charac- ter. * No Check Character Validate, but Don’t Transmit Validate and Transmit Plessey Redundancy...
GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > GS1 DataBar Omnidirectional On/Off * On GS1 DataBar Omnidirectional Redundancy If you are encountering errors when reading GS1 DataBar Omnidirectional bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > GS1 DataBar Limited On/Off * On GS1 DataBar Limited Redundancy If you are encountering errors when reading GS1 DataBar Limited bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > GS1 DataBar Expanded On/Off * On GS1 DataBar Expanded Redundancy If you are encountering errors when reading GS1 DataBar Expanded bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
GS1 DataBar Expanded Message Length Scan the bar codes below to change the message length. Refer to Message Length Description (page 6-2) for additional information. Mini- mum and Maximum lengths = 1-80. Minimum Default = 3, Maximum Default = 80. Minimum Message Length Maximum Message Length Trioptic Code...
If EAN8 to EAN13 Conversion is scanned, all EAN8 bar codes are converted to EAN13 format. Default = GS1 Emulation Off. GS1-128 Emulation GS1 DataBar Emulation GS1 Code Expansion Off EAN8 to EAN13 Conversion * GS1 Emulation Off Postal Codes The following lists linear postal codes.
Page 166
China Post (Hong Kong 2 of 5) On/Off * Off China Post (Hong Kong 2 of 5) Redundancy If you are encountering errors when reading China Post (Hong Kong 2 of 5) bar codes, you may want to adjust the redundancy count. Redundancy adjusts the number of times a bar code is decoded before transmission, which may reduce the number of errors.
Interface Keys Keyboard Function Relationships The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+ relationships apply to all terminals that can be used with the scanner. Refer to page 2-23 enable Control + ASCII mode. Function Code HEX/ASCII Value Full ASCII “CTRL”...
The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US only. The following chart indicates the equivalents of these five characters for different countries. Note: Not all countries may be supported by your device. Country Codes United States...
Page 169
IBM AT/XT and PS/2 Apple Mac/iMac ASCII Compatibles, Supported Keys WYSE PC/AT Supported Keys CR/Enter RETURN Insert Ins Help Escape Home Home Print Prnt Scrn Back Space BACKSPACE Back Tab LSHIFT TAB BACKSPACE 7 - 3...
Utilities To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Charts, beginning on page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D.
Test Menu When you scan the Test Menu On code, then scan a programming code in this manual, the scanner displays the content of a programming code. The pro- gramming function will still occur, but in addition, the content of that program- ming code is output to the terminal.
You can later write the modified settings to the scanner, or save them to a dcf file. Installing EZConfig-Scanning from the Web 1. Access the Honeywell web site at www.honeywellaidc.com 2. Click on the Resources tab. Select Download.
Resetting the Factory Defaults This selection erases all your settings and resets the scanner to the original factory defaults. If you aren’t sure what programming options are in your scanner, or you’ve changed some options and want to restore the scanner to factory default set- tings, first scan the Remove Custom Defaults bar code, then scan Activate Defaults.
Serial Programming Commands The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will pro- gram the scanner. For complete descriptions and examples of each serial pro- gramming command, refer to the corresponding programming bar code in this manual.
Storage A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the command’s operation on the device’s volatile menu configuration table. A period (.) performs the command’s operation on the device’s non-volatile menu configuration table.
Responses The device responds to serial commands with one of three responses: ACK Indicates a good command which has been processed. ENQ Indicates an invalid Tag or SubTag command. NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters.
MAX60[ACK], DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled;...
Page 179
The charts on the following pages list the factory default settings for each of the commands (indicated by an asterisk (*) on the programming pages). 9 - 5...
Menu Commands Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Product Default Settings Setting Custom Set Custom Defaults MNUCDF Defaults Save Custom DEFALT Defaults Resetting the Activate Custom DEFALT Custom Defaults Defaults Programming the Interface Plug and Play Codes Keyboard Wedge: PAP_AT...
Page 181
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Plug and Play Codes: USB Keyboard (PC) PAP124 USB Keyboard PAP125 (Mac) USB Japanese PAP134 Keyboard (PC) USB HID PAP131 HID Fallback Mode HID Fallback Mode USBFTO (Range 0-60 *5 minutes 9 - 7...
Page 182
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry USB Serial USB Serial PAP130 Commands Emulation for Windows XP, Windows Server 2003, and later USB Serial REMIFCO;PAP130 Emulation for Windows 2000 CTS/RTS Emulation USBCTS1 CTS/RTS Emulation USBCTS0 Off* ACK/NAK Mode On...
Page 183
Selection Page # Indicates a numeric * Indicates default entry Plug and Play Codes Verifone Ruby PAPRBY Terminal Gilbarco Terminal PAPGLB Honeywell Bioptic PAPBIO 2-10 Aux Port Datalogic Magellan PAPMAG 2-10 Bioptic Aux Port NCR Bioptic Aux PAPNCR 2-11 Port...
Page 185
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Kyrgyz (Cyrillic) KBDCTY79 2-17 Latin America KBDCTY14 2-17 Latvia KBDCTY42 2-17 Latvia (QWERTY) KBDCTY43 2-17 Lithuania KBDCTY44 2-17 Lithuania (IBM) KBDCTY45 2-17 Macedonia KBDCTY34 2-18 Malta KBDCTY74 2-18 Mongolian (Cyrillic) KBDCTY86...
Page 186
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Tatar KBDCTY85 2-19 Thailand KBDCTY94 2-19 Turkey F KBDCTY27 2-20 Turkey Q KBDCTY24 2-20 Ukrainian KBDCTY76 2-20 United Kingdom KBDCTY7 2-20 United Stated KBDCTY89 2-20 (Dvorak right) United States KBDCTY88 2-20...
Page 187
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Keyboard Conversion *Keyboard KBDCNV0 2-22 Conversion Off Convert all KBDCNV1 2-22 Characters to Upper Case Convert all KBDCNV1 2-22 Characters to Lower Case Keyboard Modifiers *Control + ASCII Off KBDCAS0 2-23 DOS Mode Control...
Page 189
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Word Length: Data 7 Data, 1 Stop, 2-26 232WRD3 Bits, Stop Bits, and Parity Even Parity 7 Data, 1 Stop, 232WRD0 2-26 Parity None 7 Data, 1 Stop, 232WRD6 2-26 Parity Odd...
Page 190
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry RS232 Handshaking *RTS/CTS Off 232CTS0 2-28 Flow Control, No 232CTS1 2-28 Timeout Character-Based 232CTS7 2-28 Flow Control, No Timeout Two-Direction Flow 232CTS2 2-28 Control Flow Control with 232CTS3 2-28 Timeout...
Page 191
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry NCR ACK/NAK *NCR ACK/NAK Off NCRACK0 2-31 NCR ACK/NAK On NCRACK1 2-31 Block Check *Transmit NCRBCC1 2-32 Character Don’t Transmit NCRBCC0 2-32 NCR Prefix/Suffix NCR Prefix NCRPR2## 2-32 NCR Suffix NCRSF2##...
Page 192
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Beeper Pitch - Good Low (1600 Hz) BEPFQ11600 Read (Frequency) *Medium (2350 Hz) BEPFQ12350 High (4200 Hz) BEPFQ14200 Beeper - Transmit *Before BEPWHN1 Order Transmission After Transmission BEPWHN2 Beeper Pitch - Error *Razz (100 Hz)
Page 193
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry LED Settings *Red LED Off LEDFN10 Green LED Off LEDFN20 Red LED On with LEDFN11 Good Scan *Green LED On with LEDFN21 Good Scan Red LED On with LEDFN12 Laser Green LED On with...
Page 194
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry In-Stand and Out-of- In-Stand Defaults AISDFT Stand Settings Out-of-Stand AOSDFT Defaults Presentation Mode PAPPM1 Out-of-Stand Presentation Mode PAPPM2 with CodeGate Out- of-Stand Manual Activation AISMEN0 Mode Off In-Stand *Manual Activation AISMEN1 Mode On In-Stand...
Page 195
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry In-Stand and Out-of- Laser Timeout - AISMRT##### 3-10 Stand Settings Trigger Release In- (continued) Stand (Range 1 - 65525) *0 ms Laser Timeout - AOSMPT##### 3-10 Trigger Hold Out-of- Stand (Range 1 - 65525) *30000 ms...
Page 196
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry In-Stand and Out-of- *End Object AISOGD1 3-12 Stand Settings Detection After (continued) Good Read In-Stand Do Not End Object AOSOGD0 3-12 Detection After Good Read Out-of- Stand *End Object AOSOGD1 3-12...
Page 197
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Character Activation *Off HSTCEN0 3-13 Mode HSTCEN1 3-13 Activation Character HSTACH## 3-14 Do Not End HSTCGD0 3-14 Character Activation After Good Read *End Character HSTCGD1 3-14 Activation After Good Read Character Activation HSTCDT#####...
Page 198
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Require Output Required SEQ_EN2 3-21 Sequence On/Not Required SEQ_EN1 3-21 *Off SEQ_EN0 3-21 No Read SHWNRD1 3-21 *Off SHWNRD0 3-21 Prefix/Suffix Selections Add CR Suffix to All Symbologies VSUFCR Prefix Add Prefix...
Page 199
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Interfunction Delay Range 0 - 1000 DLYFNC## (5ms increments) Intermessage Delay Range 0 - 1000 DLYMSG## (5ms increments) Data Formatter Selections Data Format Editor *Default Data DFMDF3 Format (None) Enter Data Format DFMBK3##...
Page 200
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Primary/Alternate Primary Data ALTFNM0 5-10 Data Formats Format Data Format 1 ALTFNM1 5-10 Data Format 2 ALTFNM2 5-10 Data Format 3 ALTFNM3 5-10 Single Scan Data Single Scan-Primary VSAF_0 5-11 Format Change...
Page 201
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Codabar Check *No Check Char. CBRCK20 Char. Validate Modulo 16, CBRCK21 But Don’t Transmit Validate Modulo 16, CBRCK22 and Transmit Validate Modulo 7 CBRCK23 CD, But Don’t Transmit Validate Modulo 7 CBRCK24...
Page 203
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry NEC 2 of 5 Default All NEC N25DFT 6-12 2 of 5 Settings *Off N25ENA0 6-12 N25ENA1 6-12 NEC 2 of 5 Check *No Check Char. N25CK20 6-13 Digit Validate, But Don’t...
Page 204
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Straight 2 of 5 IATA Default All Straight 2 A25DFT 6-17 of 5 IATA Settings Straight 2 of 5 IATA *Off A25ENA0 6-17 A25ENA1 6-17 Straight 2 of 5 IATA Range (0 - 10) *0 A25VOT## 6-17...
Page 206
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry ISBT128 Predefined * Donation ID ISBPCS0 6-25 Concatenation Number (001) Sequences and ABO/RhD Blood Groups (002) Donation ID Number ISBPCS1 6-25 (001) and Donor ID Number (019) Donation ID Number ISBPCS2 6-25...
Page 207
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry ISBT 128 User- 1st Left Identifier (0- ISBUL1## 6-27 Defined 255) *0 Concatenation 2nd Left Identifier (0- ISBUL2## 6-27 Sequences 255) *0 1st Right Identifier ISBUR1## 6-27 (0-255) *0 2nd Right Identifier ISBUR2##...
Page 208
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry Telepen Default All Telepen TELDFT 6-32 Settings *Off TELENA0 6-32 TELENA1 6-32 Telepen Output *AIM Telepen Output TELOLD0 6-32 Original Telepen TELOLD1 6-32 Output Telepen Redundancy Range (0 - 10) *0 TELVOT## 6-33 Telepen Message...
Page 209
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry UPC-A/EAN-13 with *Off CPNENA0 6-37 Extended Coupon Allow Concatenation CPNENA1 6-37 Code Require CPNENA2 6-37 Concatenation UPC-A Number * Don’t Require ARQSY40 6-37 System 4 Addenda Coupon Code Required Require Coupon ARQSY41...
Page 210
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry UPC-E0 Expand *Off UPEEXP0 6-40 UPEEXP1 6-40 UPC-E0 Number UPEEXN1 6-40 System UPEEXN0 6-40 UPC-E0 Check Digit *Off UPECKX0 6-41 UPECKX1 6-41 UPC-E0 Leading *Off UPENSX0 6-41 Zero UPENSX1 6-41...
Page 211
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry EAN/JAN-13 2 Digit 2 Digit Addenda On E13AD21 6-45 Addenda *2 Digit Addenda Off E13AD20 6-45 5 Digit Addenda On E13AD51 6-45 *5 Digit Addenda Off E13AD50 6-45 EAN/JAN-13 *Not Required...
Page 213
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry ISSN Translate *Off E13ISS0 6-53 E13ISS1 6-53 Reformat On E13ISR1 6-53 *Reformat Off E13ISR0 6-53 EAN/JAN-8 Default All EAN/ EA8DFT 6-54 JAN 8 Settings EA8ENA0 6-54 EA8ENA1 6-54 EAN/JAN-8 Check EA8CKX0...
Page 214
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry MSI Check Character *Validate Type 10, MSICHK0 6-58 but Don’t Transmit Validate Type 10 and MSICHK1 6-58 Transmit Validate 2 Type 10 MSICHK2 6-58 Chars, but Don’t Transmit Validate 2 Type 10 MSICHK3...
Page 215
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry GS1 DataBar Default All RSSDFT 6-61 Omnidirectional GS1 DataBar Omnidirectional Settings RSSENA0 6-61 RSSENA1 6-61 GS1 DataBar Range (0 - 10) *0 RSSVOT## 6-61 Omnidirectional Redundancy GS1 DataBar Limited Default All GS1 RSLDFT 6-62...
Page 216
Serial Command Setting Selection Page # Indicates a numeric * Indicates default entry GS1 Emulation GS1-128 Emulation EANEMU1 6-65 GS1 DataBar EANEMU2 6-65 Emulation GS1 Code EANEMU3 6-65 Expansion Off EAN8 to EAN13 EANEMU4 6-65 Conversion *GS1 Emulation Off EANEMU0 6-65 Postal Codes China Post (Hong...
Depth of Field Typical Performance Bar code Standard Range 5.0 mil 57 mm - 139 mm (2.2” - 5.5”) 7.5 mil 28 mm - 245 mm (1.1” - 9.7”) 10.4 mil 9 mm - 369 mm (0.4” - 14.5”) 13 mil 0 mm - 446 mm (0.0”...
7 Supply power input +5V power 8 Keyboard data Note: Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty.
9 Data + 10 Data - Note: Pin assignments are not compatible with Honeywell legacy products. Use of a cable with improper pin assignments may lead to damage to the unit. Use of any cables not provided by the manufacturer may result in damage not covered by your warranty.
Maintenance Repairs Repairs and/or upgrades are not to be performed on this product. These ser- vices are to be performed only by an authorized service center (see Customer Support on page 12-1). Maintenance Your device provides reliable and efficient operation with a minimum of care. Although specific maintenance is not required, the following periodic checks ensure dependable operation: Cleaning the Device:...
• Order replacement cables from Honeywell or from an authorized distributor. • When ordering a replacement cable, specify the cable part number of the original interface cable. Replacing an Interface Cable 1. Turn the power to the host system OFF.
Page 225
• You need to program a suffix. Programming a suffix enables the scanner to output the bar code data plus the key you need (such as “CR”) to enter the data into your application. Refer to Prefix/Suffix Overview on page 4- 1 for further information.
For our latest contact information, please check our website at the link above. Limited Warranty Honeywell International Inc. (“HII”) warrants its products to be free from defects in materials and workmanship and to conform to HII’s published specifications applicable to the products purchased at the time of shipment. This warranty does not cover any HII product which is (i) improperly installed or used;...
Page 228
This includes but is not limited to: cables, power supplies, cradles, and docking stations. HII extends these warranties only to the first end-users of the products. These warranties are non-transferable. The duration of the limited warranty for the Voyager 1250g scanner is five (5) years. 12 - 2...
Symbologies, 99) entry. Refer to Data Editing beginning on page 4-1 and Data Formatting beginning on page 5-1 for information about using Code ID and AIM ID. Linear Symbologies Honeywell Possible Symbology modifiers All Symbologies Codabar Code 11 Code 128...
Page 230
Telepen 0, 1, 2, 3, 8, 9, A, B, C UPC-A UPC-A with Add-On UPC-A with Extended Coupon Code UPC-E UPC-E with Add-On UPC-E1 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C A - 2...
Postal Symbologies Honeywell Possible Symbology modifiers All Symbologies China Post ASCII Conversion Chart (Code Page 1252) In keyboard applications, ASCII Control Characters can be represented in 3 dif- ferent ways, as shown below. The CTRL+X function is OS and application dependent.
Non-printable Keyboard Control + ASCII (CTRL+X) Mode ASCII control characters Windows Mode Control + X Mode On (KBDCAS2) Control + X Mode Off CTRL + X Char CTRL + X (KBDCAS0) function Home CTRL+ Q Quit PrtScn CTRL+ R Backspace CTRL+ S Save Back Tab...
Page 233
Printable Characters (Continued) Character Character DEC HEX Character < > ⌂ Extended ASCII Characters PS2 Scan DEC HEX CP 1252 ASCII Alternate Extended Code ↑ Ç 0x48 up arrow ↓ ü 0x50 down arrow → ‚ é 0x4B right arrow ←...
Page 234
Extended ASCII Characters (Continued) PS2 Scan DEC HEX CP 1252 ASCII Alternate Extended Code ì Reserved Ž Ä Numeric Keypad Enter 0x1C Å Numeric Keypad / 0x35 É 0x3B ‘ æ 0x3C ’ Æ 0x3D “ ô 0x3E ” ö 0x3F •...
Character Replacement ISO/IEC 2022 2 (default) Binary Code page Default “Automatic National Character replacement” will select the below Honeywell Code Page options for Code128, Code 39 and Code 93. United States ISO/IEC 646-06 Canada ISO /IEC 646-121 Canada ISO /IEC 646-122...
Page 238
Code Page Selection Standard Keyboard Honeywell Method/Country Country Code Page Option Danmark ISO/IEC 646-08 Norway ISO/IEC 646-60 Italy ISO/IEC 646-15 Portugal ISO/IEC 646-16 Spain ISO/IEC 646-17 Spain ISO/IEC 646-85 A - 10...
Page 239
à â ç ê î ô é ù è û à â ç ê É ô é ù è û ⎯ ¥ ⎯ ¥ £ ˜ £ à ° ç § µ é ù è ¨ § Ä Ö Ü ä...
Programming Chart Save Discard Reset Note: If you make an error while scanning the letters or digits (before scanning Save), scan Discard, scan the correct letters or digits, and Save again.
Page 246
Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 VG1250-UG Rev D 9/13...
Need help?
Do you have a question about the Voyager 1250g and is the answer not in the manual?
Questions and answers