SAUNACORE
LIGHT Indicator-
FAN Indicator-
HEAT Indicator-
STANDBY Indicator-
(optional)
ON/OFF Button-
(+Temp Set Button
Hold Down)
Operation Instruction for Sauna Commander Control
1. Activate main power from Electrical panel.
2. Once the power is on, the current room temperature will be
displayed in the "Commander" readout window.
3. To activate the sauna heater press and release the ON/OFF
button in the center of the Commander Control.
4. The Light and Heat displays will illuminate. The heater is now
activated and the sauna interior light has been activated.
5. To set/change the sauna temperature at any time, hold the
ON/OFF button down until the temperature you desire is set,
than release the button. The temperature will be displayed in
readout window. The temperature can be set between 30
degrees Celsius up to 90 degrees Celsius at one degree
increments. The temperature set will remain unless the main
power is turned off, if this occurs it will be set at 30 degrees
Celsius.
6. If your sauna does have a fan connected to the Commander
Connection Box, it will automatically activate when the sauna
reach a certain temperature and the Fan display will illuminate.
7. To shut off the heater press and release the ON/OFF button
located in the center of the Commander Control pad.
8. If your heater has the Standby feature it will activate
immedately after it has been turned off. The heater at this
point will re-activate and remain on for 1 hour of operation (1
min on /1 min off simutaneouly), it will then finally shut off.
9. During the Standby mode, if you wish to activate the heater at
full capacity and bypass the Standby mode, simply press the
ON/OFF button.
10. Whenever the heater shuts off, the sauna light will remain on
for an extra 5 to 10 minutes and it may blink on-off to notify
you that it is ready to shut down.
Note:
•
All sauna heaters will automatically shut off in 30 minutes
(may be set for 60 minutes).
•
If the sauna system is 600 volts, 450 volts, 380 volts, 240
volts, or 208 volts; the light bulb and fan MUST BE 240V. If
the sauna system is 120 volts, then the light bulb and fan
MUST BE 120V.
•
Some of the sauna systems may operate with dual voltage.
•
For safety precautions, when the sauna is not being used
and during service, ensure that the main power supply is
switched off.
Commander Control
3
Need help?
Do you have a question about the Heaters and is the answer not in the manual?
Questions and answers
What size wire to use from the controler to the heater (I.e. 14/2 )
The power supply wires from the Saunacore heater controller to the heater must use a suitable AWG wire rated for at least 90°C (190°F) and must be copper.
This answer is automatically generated