ORTAL Clear 150 Tunnel Installation & Operation Manual

Hide thumbs Also See for Clear 150 Tunnel:

Advertisement

ORTAL Heating Solutions Ltd.
INSTALLATION & OPERATION MANUAL
Instruction for Burner 135 Models:
Clear 150, Clear 150 RS/LS/TS, Clear 150 Tunnel, Space Creator 150,
Stand Alone 150, Clear 170, Clear 170 RS/LS/TS, Stand Alone 170,
Clear 170 Tunnel
The Ortal direct vent appliances have been tested and approved by CSA for safety and
efficiency for use with either Natural Gas (NG) or Propane (LP).
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Clear 150 Tunnel and is the answer not in the manual?

Questions and answers

Summary of Contents for ORTAL Clear 150 Tunnel

  • Page 1 Stand Alone 150, Clear 170, Clear 170 RS/LS/TS, Stand Alone 170, Clear 170 Tunnel The Ortal direct vent appliances have been tested and approved by CSA for safety and efficiency for use with either Natural Gas (NG) or Propane (LP).
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Page Introduction to Ortal and Company Profile Warnings Models, Dimensions and Configurations Product Specifications Gas Pressure and Power Output Installation Instructions and Checklist Locating Your Gas Fire Place Minimum Clearance to Combustible Materials Install Vent System (also see Appendix A) Restrictors &...
  • Page 3: Introduction To Ortal And Company Profile

    INTRODUCTION Company Profile Welcome to Ortal and Ortal USA.  Ortal Heating Solutions has been one of the leaders  and innovators in fireplace technology for over 20 years.  Ortal expanded its market to  include Continental Europe and the United Kingdom and most recently, through Ortal  USA, Ortal is proud to span the globe with fireplace products in the United States and  Canada.   Ortal and Ortal USA welcomes you as a valued customers and new owner of  an Ortal direct vent appliance.     Specializing in indoor gas fireplaces, Ortal’s designs make up an inseparable part of the  living space in homes and other settings.  Infusing both form and function our direct  vent fireplace heaters are designed to be aesthetically pleasing.  Ortal USA offers a  variety of standard models and design concepts, each one being efficient and safe.   Ortal’s balance flue direct vent fireplaces meet CSA standards for safety and efficiency.    There is no contact of hot surfaces with the walls or the roof of the building.    Ortal Heating Solutions gives meticulous attention to the most stringent design  requirements, quality of materials, finishes and complementary service for the entire  heating system.  The company constantly updates its knowledge of the latest  innovations and worldwide trends.      Ortal USA invites your queries and requests for custom design are welcome.     The following installation and operation manual is for you, your architect’s and your  installer’s use.  Please keep it readily available and always contact Ortal USA with any  questions you may have.    We appreciate you for choosing Ortal USA for your fireplace needs.    Thank you,    Ortal and Ortal USA...
  • Page 4: Warnings

    Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this appliance. SAVE THESE INSTRUCTIONS Make yourself fully aware of all the following instructions and the many features of the Ortal direct vent gas fireplace appliance. INSTALLER: Leave this manual with the appliance. OWNER: Keep this manual for future reference.
  • Page 5 WARNING : Glass Handling The glass must ONLY be removed by an authorized &/or qualified installer. The authorized technician should ONLY remove the glass with the glass vacuum holders supplied manufacturer. Lower glass rest special wooden/polyurethane support provided, and fit the second support to the upper edge of the glass.
  • Page 6: Models, Dimensions And Configurations

    Dimensions provided in the diagrams are shown in “millimeters” and “[inches]”. All vents for this series, Burner 135, are DuraVent 5/8”. Adaptors are not required. Model Page Clear 150 Clear 150 RS/LS/TS Clear 150 Tunnel Space Creator 150 Stand Alone 150 Clear 170...
  • Page 7: Clear 150

    Model Clear 150...
  • Page 8: Clear 150 Rs/Ls/Ts

    Clear 150 RS/LS Clear 150 TS...
  • Page 9: Clear 150 Tunnel

    Clear 150 Tunnel...
  • Page 10: Space Creator 150

    Space Creator 150...
  • Page 11: Stand Alone 150

    Stand Alone 150...
  • Page 12: Clear 170

    Clear 170...
  • Page 13: Clear 170 Rs/Ls/Ts

    Clear 170 RS/LS Clear 170 TS...
  • Page 14: Stand Alone 170

    Stand Alone 170...
  • Page 15: Clear 170 Tunnel

    Clear 170 Tunnel...
  • Page 16: Product Specifications

    The appliance is not approved for closet installation. The appliance must be installed according Ortal USA requirements in addition to any local codes that may apply. If none exist then the current CSA installation code must be followed: ...
  • Page 17: Installation Instructions And Checklist

    INSTALLATION INSTRUCTIONS Installation Checklist 1. Identify appliance installation location (based on the following): a. Room location b. Clearances to combustibles c. Venting requirements d. Mantle clearances e. Framing and finishing requirements (surrounding framing and materials to be completed after fireplace installation) 2.
  • Page 18: Locating Your Gas Fireplace

    Mantels constructed of non-combustible materials may be installed at any height above the appliance opening; however, do not allow anything to hang below the fireplace hood. Recommendation: Ortal recommends the use of high temperature paint (rated 175° F or higher) on the underside of the mantel.
  • Page 19 CLEARANCE DIAGRAMS...
  • Page 25: Install Vent System (Also See

    Install Vent System Follow the instructions in appendix A. Fireplace Restrictors & Vent Arrangement The following drawing and table show the options allowed for both vertical and horizontal positioning of the vents and the required restrictor for the burner 135 models. With this information it is possible to find the allowable horizontal or vertical path of the vent.
  • Page 26 Schematic Drawing...
  • Page 27 Table for Restrictor selection, Burner 135 Direct Vent 5x8” Clear 150, Clear 150 RS/LS/TS, Clear 150 Tunnel, Space Creator 150, Stand Alone 150, Clear 170, Clear 170 RS/LS/TS, Stand Alone 170, Clear 170 Tunnel Note: Symbol (-) is not allowed. (R) = restrictor size. R=0 means no restrictor is needed.
  • Page 28: Routing Of Gas Line

    Routing of Gas Line Correctly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed as per requirements outlined in the latest edition of the National Fuel Gas Code, NFPA 54 (USA) or CAN/CSA-B1491 (Canada). Never use galvanized or plastic pipe, unless specified specifically for use with gas.
  • Page 29: Burner Inspection

    Not all installers are authorized to provide gas conversion services. Glass Panels 5mm ceramic glass front and side panels. Contact Ortal USA for replacement parts if required. Handling the Glass The glass must ONLY be removed by an authorized qualified installer. The technician should ONLY remove the glass with the glass vacuum holders supplied by the manufacturer.
  • Page 31 GLASS PROTECTION DURING MAINTENANCE Special wooden supports Glass Vacuum glass holders Keep anti slip angle...
  • Page 32: Interior Design Media

    Contact Ortal USA for current approved products. Chips Pebbles Various colors Reflective Panels. Instructions not included with this manual. Contact Ortal USA for current available products and installation requirements. Faceplate. Provided by others. Instructions not included with this manual. Controls Remote Control (standard) Wall Thermostat.
  • Page 33: Insulation For Cold Climate

    Warning:  DO NOT install the interior design media until the appliance installation is complete, the gas line is connected and tested for leaks and the initial burner operation has been inspected and confirmed.  ONLY install media which is provided by the manufacturer or otherwise specifically approved by the manufacturer for installation and operation with the unit.
  • Page 34: Operating Instructions And Warnings

    OPERATING INSTRUCTIONS For your safety read carefully before lighting the fireplace. WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do NOT operate the appliance if: ...
  • Page 35: General Maintenance Instructions

    MAINTENANCE INSTRUCTIONS General Maintenance Instructions WARNING Turn off the gas BEFORE servicing the fireplace. It is recommended that a qualified service technician perform a routine inspection at the beginning of each heating season. Never operate the appliance without the glass properly secured in place WARNING The glass must ONLY be removed by an authorized qualified installer.
  • Page 36: Burner Maintenance

    Burner Maintenance The flame from the burner should be visually checked. The flame should be blue and yellow and candle-like in appearance. Pilot Maintenance The pilot flame must be visually checked. Always be present when the fireplace is in operation. The pilot flame has two distinct flames, one engulfing the thermocouple, and the other reaching the main burner.
  • Page 37: Nozzle Details

    3. Ensure that there is no foreign material in the vents. Survey by removing the cap and shining a light down the vent. 4. Check all joints and pipes to make sure that nothing has been disturbed or loosened. Nozzle Details...
  • Page 38 Nozzle Details (continued)
  • Page 39: Manufacturer And Supplier Information

    CONTACT INFORMATION ORTAL Heating Solutions Ltd. (Israel) ORTAL Heating Systems Industrial Zone B Neve Neeman, Hod-Hasharon Israel Tel: 011 972 9 7402828 Fax: 011 972 9 7402687 E-mail: sales@ortal-heat.co.il Website: www.ortal-heat.com ORTAL USA, Inc. 7618 Jellico Avenue Northridge, CA 91325...
  • Page 40: Label

    Check one (check space to the right of the model name): Clear 150 ____ Clear 150 RS____ Clear 150LS____ Clear 150TS ____ Clear 150 Tunnel ____ Space Creator 150 ____ Stand Alone 150 ____ Clear 170 ____ Clear 170 RS____...
  • Page 41: List Of Appendices

    TABLE OF APPENDICES Appendix Content Product/ Manufacturer Vent Installation DuraVent Electric Control Installation Mertik Maxitrol Electric Control Operation Mertik Maxitrol Silicon Product and Application Rutland Interior Media Layout Ortal...
  • Page 42 Appendix A Installation Instructions 9HQWLQJ 6\VWHP )RU 'LUHFW 9HQW *DV 6WRYHV DQG )LUHSODFHV...
  • Page 43 Appendix A $ 0$-25 &$86( 2) 9(17 5(/$7(' ),5(6 ,6 )$,/85( 72 0$,17$,1 5(48,5(' &/($5$1&(6 $,5 63$&(6 72 &20%867,%/( 0$7(5,$/6 ,7 ,6 2) 7+( 870267 ,03257$1&( 7+$7 '28%/( :$// ',5(&79(17 352 %( ,167$//(' 21/< ,1 $&&25'$1&( :,7+ 7+(6( ,16758&7,216 ,03257$17 'HDU &XVWRPHU ,QVWDOOHU RU (QG 8VHU 5HDG WKURXJK DOO RI WKHVH LQVWUXFWLRQV :H ZHOFRPH DQ\ FRPPHQWV UHJDUGLQJ PDWWHUV...
  • Page 44 Appendix A VENTING SYSTEM FOR DIRECT VENT GAS STOVES AND FIREPLACES )RU WKH PRVW XSWRGDWH LQVWDOODWLRQ LQVWUXFWLRQV VHH ZZZGXUDYHQWFRP &217(176 $SSOLFDWLRQ _ :DUQLQJ _ 6DIHW\ ,QVWDOODWLRQ 3UHFDXWLRQV                2SWLRQV _ 3ODQQLQJ <RXU ,QVWDOODWLRQ                                  +RUL]RQWDO ,QVWDOODWLRQ                                             6QRUNHOV                                                     ...
  • Page 45 Appendix A $33/,&$7,21 QHDUE\ FRPEXVWLEOH VXUIDFHV %H VXUH WR FKHFN WKH YHQW WHUPLQDWLRQ 7KHVH LQVWUXFWLRQV DSSO\ WR WKH 0 * FOHDUDQFH UHTXLUHPHQWV IURP GHFNV 'XUD9HQW 'LUHFW9HQW 3UR ´[´ ZLQGRZV VRI¿WV JDV UHJXODWRUV DLU DQG ´[´ V\VWHPV 7KLV YHQWLQJ VXSSO\ LQOHWV DQG SXEOLF ZDONZD\V V\VWHP LQ FRPELQDWLRQ ZLWK WKH JDV DV VSHFL¿HG LQ WKHVH LQVWDOODWLRQ DSSOLDQFH KDV EHHQ WHVWHG DQG OLVWHG...
  • Page 46 Appendix A E\ 0 * 'XUD9HQW RU WKH DSSOLDQFH PDQXIDFWXUHU ‡ ,QVWDOODWLRQ RWKHU WKDQ DV LQVWUXFWHG ROUND HORIZONTAL E\ 0 * 'XUD9HQW RU WKH DSSOLDQFH TERMINATION CAP SHOWN PDQXIDFWXUHU PIPE &RQVXOW \RXU ORFDO EXLOGLQJ FRGHV SECTION EHIRUH EHJLQQLQJ WKH LQVWDOODWLRQ WALL APPLIANCE 237,216...
  • Page 47 Appendix A LPSRUWDQW WR QRWH WKH ZDOO WKLFNQHVV VERTICAL HIGH WIND 6HOHFW WKH DPRXQW RI YHUWLFDO ULVH TERMINATION CAP SHOWN GHVLUHG RU UHTXLUHG IRU ³YHUWLFDOWR KRUL]RQWDO´ LQVWDOODWLRQV YHULI\ WKDW LW LV ZLWKLQ WKH DSSOLDQFH PDQXIDFWXUHU¶V STORM PLQLPXP DQG PD[LPXP OLPLWV  7R COLLAR GHWHUPLQH WKH OHQJWK RI YHQW SLSH UHTXLUHG IRU YHUWLFDO LQVWDOODWLRQV...
  • Page 48 Appendix A 1RWHV  7ZLVWORFN SURFHGXUH /LQH XS ORFNLQJ OXJV RQ PDOH DQG IHPDOH HQGV RI SLSH VHFWLRQV ,QVHUW WKH PDOH HQG RI SLSH LQWR WKH IHPDOH HQG XQWLO WKH ORFNLQJ OXJV DUH FRYHUHG 7ZLVW WKH IHPDOH HQG FORFNZLVH DQ HLJKWK RI D WXUQ WR ORFN VHFWLRQV WRJHWKHU )LJ   6FUHZV DUH QRW UHTXLUHG WR VHFXUH WKH MRLQW EXW DUH DFFHSWDEOH SURYLGHG WKH\...
  • Page 49 Appendix A 7$%/(  ',5(&79(17 352 )5$0,1* 25 &87287 ',0(16,216 672&. 180%(5 &20321(17 '(6&5,37,21 6,=( '9$:7 :DOO 7KLPEOH ´[ ´ '9$:76 :DOO 7KLPEOH 6PDOO ´[ ´ '9$:78 :DOO 7KLPEOH 8QLYHUVDO ´[ ´ '9$&6 &HLOLQJ 6XSSRUW ´[ ´ '9$)6 )LUH 6WRS ´[ ´...
  • Page 50 Appendix A H &OHDUDQFH WR DQ RXWVLGH FRUQHU DV WHVWHG E\ DSSOLDQFH PDQXIDFWXUHU WOOD SCREWS I &OHDUDQFH WR DQ LQVLGH FRUQHU DV WHVWHG E\ DSSOLDQFH PDQXIDFWXUHU J 1RW WR EH LQVWDOOHG DERYH D PHWHU UHJXODWRU DVVHPEO\ ZLWKLQ  IHHW KRUL]RQWDOO\ IURP WKH FHQWHUOLQH RI WKH UHJXODWRU K &OHDUDQFH WR D VHUYLFH UHJXODWRU YHQW RXWOHW  IHHW PLQLPXP...
  • Page 51 Appendix A 6125.(/6 )RU LQVWDOODWLRQV UHTXLULQJ D YHUWLFDO ULVH RQ WKH H[WHULRU RI WKH EXLOGLQJ LQFK DQG LQFK WDOO 6QRUNHO 7HUPLQDWLRQV DUH DYDLODEOH )LJ   )ROORZ WKH VDPH JHQHUDO LQVWDOODWLRQ SHEET METAL SURFHGXUHV DV XVHG IRU D VWDQGDUG SCREWS +RUL]RQWDO 7HUPLQDWLRQ 7KH VWDQGDUG :DOO 7KLPEOH RU :DOO )LUHVWRS FDQ EH XVHG ZLWK WKH 6QRUNHO EXW WKH WALL...
  • Page 52 Appendix A SNORKEL OPTIONAL DVA-WTU ADJUST AND SECURE TELESCOPING THIMBLE SLEEVES WITH SCREWS 12" MINIMUM )LJXUH  SNORKEL WALL THIMBLE COVER 12" MINIMUM ADEQUATE DRAINAGE )LJXUH ...
  • Page 53 Appendix A 9,1</ 6,',1* ,167$//$7,21 VINYL SIDING, STUCCO OR OTHER 7KH 9LQ\O 6LGLQJ 6WDQGRII SUHYHQWV SIDING MATERIAL ASSEMBLE VINYL STANDOFF/COUNTER H[FHVVLYH KHDW IURP SRWHQWLDOO\ ZDUSLQJ FLASHING IN SPECIFIC ORDER RU PHOWLQJ WKH YLQ\O VLGLQJ PDWHULDO 9LQ\O 6LGLQJ 6WDQGRIIV DUH QRW XVHG ZLWK 6QRUNHOV 7KH 9LQ\O 6LGLQJ 6WDQGRII LV DYDLODEOH LQ HLWKHU D SLHFH YHUVLRQ RU D SLHFH YHUVLRQ...
  • Page 54 Appendix A FORFNZLVH SODFH WKH OHIW VLGH WKH PDWHULDO FRYHU 7HUPLQDWLRQ &DS RU ERWWRP VLGH DQG WKHQ WKH ULJKW VLGH DLU LQOHWV 7KH &RXQWHU )ODVKLQJ LV DURXQG WKH RSHQLQJ LQ WKH VLGLQJ 5HIHU DYDLODEOH LQ ERWK SLHFH DQG SLHFH WR )LJXUH  YHUVLRQV ƒ...
  • Page 55 Appendix A CEILING JOISTS AND FRAME MARK LOCATION MARK AND DRILL FRAMING PLUMB DECORATIVE CEILING SUPPORT COVER 1 1/2" WOOD SCREWS )LJXUH  )LJXUH  9(57,&$/ ,167$//$7,21 6WHS  &KHFN WKH DSSOLDQFH RIIVHW OLPLWDWLRQV PDQXIDFWXUHU¶V LQVWDOODWLRQ LQVWUXFWLRQV 6WHS  6HW WKH JDV DSSOLDQFH LQ WKH IRU UHTXLUHG FOHDUDQFHV DLU VSDFHV WR GHVLUHG ORFDWLRQ 'URS D SOXPE ERE FRPEXVWLEOHV ZKHQ SDVVLQJ WKURXJK...
  • Page 56 Appendix A 1RWHV )LJ   'HWHUPLQH LI FHLOLQJ MRLVWV  ,I H[DFW OHQJWKV RU GLVWDQFHV PXVW URRI UDIWHUV IUDPLQJ RU RWKHU PDWHULDOV EH PHW EHWZHHQ (OERZ RIIVHWV RU ZLOO REVWUXFW WKH YHQWLQJ V\VWHP <RX HOVHZKHUH XVH WKH 3LSH ([WHQVLRQV PD\ ZLVK WR UHORFDWH WKH DSSOLDQFH RU WR DGMXVW RQWR VWDQGDUG 3LSH 6HFWLRQV WR RIIVHW WR DYRLG FXWWLQJ ORDGEHDULQJ )LJ  ...
  • Page 57 Appendix A XQWLO WKH KHLJKW RI WKH V\VWHP EHIRUH 7$%/(  DGGLQJ WKH &DS PHHWV WKH PLQLPXP 522) 3,7&+ 0,1,080 +(,*+7 0LQLP EXLOGLQJ FRGH UHTXLUHPHQWV DV )HHW 0HWHUV GHVFULEHG LQ 7DEOH  DQG )LJ   )ODW WR  1RWH WKDW IRU VWHHS URRI SLWFKHV WKH 2YHU  WR   YHQW KHLJKW PXVW EH LQFUHDVHG ,Q...
  • Page 58 Appendix A OPTIONAL LOW PROFILE TERMINATION CAP HIGH WIND VERTICAL SECURE FLASHING TERMINATION WITH NON-HARDENING SEALANT AND ROOFING NAILS STORM COLLAR ROOF FLASHING )LJXUH  NAILS ATTIC WKH YHQW SLSH DQG WKH FRPEXVWLEOH INSULATION SHIELD VXUIDFHV RI WKH HQFORVXUH 'R QRW ¿OO UHTXLUHG DLU VSDFHV ZLWK LQVXODWLRQ  ,I YHQWLQJ V\VWHP SDVVHV WKURXJK DQ DWWLF VSDFH WKH $WWLF ,QVXODWLRQ...
  • Page 59 Appendix A &$7+('5$/ &(,/,1* LEVEL ,167$//$7,21 6WHS  )ROORZ LQVWDOODWLRQ 6WHSV  DQG  XQGHU 9HUWLFDO 7HUPLQDWLRQV CATHEDRAL 2' MIN 6WHS  8VLQJ WKH SOXPE ERE PDUN BELOW CEILING FINISHED SUPPORT BOX WKH FHQWHUOLQH RI WKH YHQWLQJ V\VWHP CEILING RQ WKH FHLOLQJ DQG GULOO D VPDOO KROH WKURXJK WKH FHLOLQJ DQG URRI DW WKLV CUT HOLE 1/8"...
  • Page 60 Appendix A 6WHS  3ODFH WKH 6XSSRUW &ODPS SURYLGHG ZLWK WKH 6XSSRUW %R[ LQVLGH WKH 6XSSRUW %R[ DW WKH ERWWRP  DQG VHFXUH WR WKH 3LSH 6HFWLRQ 7KH &ODPS DOORZV WKH 6XSSRUW %R[ WR VXSSRUW WKH ZHLJKW RI WKH 3LSH 6HFWLRQV &RQWLQXH WR DGG 3LSH 6HFWLRQV XQWLO \RX DUH DERYH WKH URRÀLQH 6WHS  )ROORZ 6WHSV  WKURXJK...
  • Page 61 Appendix A *(1(5$/ 0$,17(1$1&( /$%(/6 $OO FRPSRQHQWV DUH &RQGXFW DQ LQVSHFWLRQ RI WKH YHQWLQJ ODEHOHG ZLWK WKH DSSURSULDWH V\VWHP DQQXDOO\ 5HFRPPHQGHG LGHQWL¿FDWLRQ LQIRUPDWLRQ DQG WKH 8/ DUHDV WR LQVSHFW DUH DV IROORZV OLVWLQJ GDWD ZKHUH DSSOLFDEOH  &KHFN DUHDV RI WKH 9HQWLQJ 6\VWHP ZKLFK DUH H[SRVHG WR WKH HOHPHQWV IRU FRUURVLRQ 7KHVH ZLOO DSSHDU DV UXVW VSRWV RU VWUHDNV DQG LQ H[WUHPH...
  • Page 63 Appendix A ROUND, SCONCE OR 6833/(0(17$/ &$1$',$1 SQUARE HORIZONTAL TERMINATION CAP ,16758&7,216 :KHQ LQVWDOOLQJ 'LUHFW9HQW 3UR RQ DECORATIVE CEILING DSSOLDQFHV LQ &DQDGD D SLHFH :DOO SUPPORT/WALL THIMBLE COVER 7KLPEOH LV UHTXLUHG LQ RUGHU WR FRPSO\ ZLWK ,5  )LJ  DQG )LJ   &XW 2 PIECE APPLIANCE DQG IUDPH DQ RSHQLQJ LQ WKH ZDOO LQ...
  • Page 64 Appendix A VERTICAL HIGH WIND OR LOW PROFILE TERMINATION CAP STORM COLLAR ROOF FLASHING CEILING FIRESTOP ROUND CEILING SUPPORT/WALL THIMBLE COVER CATHEDRAL CEILING SUPPORT BOX PIPE SECTION PIPE SECTION APPLIANCE ADAPTOR )LJXUH ...
  • Page 65 Appendix A M&G DURAVENT WARRANTY M&G DuraVent, Inc. (“DuraVent”) provides this limited lifetime warranty for all of its products to the original purchaser, with the exception of Ventinox (lifetime), DuraBlack (five years) and all Termination Caps (five years). Subject to the limitations set forth below, DuraVent warrants that its products will be free from substantial defects in material or manufacturing, if properly installed, maintained and used.
  • Page 66 APPENDIX B Mertik Maxitrol GV60 Remote Electronic Ignition and Control System...
  • Page 67 APPENDIX B...
  • Page 68 APPENDIX B...
  • Page 69 APPENDIX B...
  • Page 70 APPENDIX B...
  • Page 71 APPENDIX B...
  • Page 72 APPENDIX B...
  • Page 73 APPENDIX B...
  • Page 74 APPENDIX B...
  • Page 75 APPENDIX B...
  • Page 76 APPENDIX B...
  • Page 77 APPENDIX B...
  • Page 78 APPENDIX C...
  • Page 79 APPENDIX C...
  • Page 80 APPENDIX C...
  • Page 81 APPENDIX C...
  • Page 82 APPENDIX C...
  • Page 83 APPENDIX C...
  • Page 84 APPENDIX C...
  • Page 85 APPENDIX C...
  • Page 86 APPENDIX C WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 87 APPENDIX C WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance, voiding its warranty.
  • Page 88 APPENDIX C The Installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 - latest edition. (In Canada, the current .CAN/CSA-B149.1 installation code). Where applicable the appliance, when installed, must be electrically grounded and wired in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition, or the Canadian Electrical Code, CSA C22.1 - latest edition.
  • Page 93 Appendix D Technical Data Sheet Rutland Fire Clay Company P.O. Box 340, Rutland, VT 05702-0340 (800) 544-1307 Fax (802) 775-5262 Outside US & Canada Call (802) 775-5519 Web Site: www.rutland.com 500°F RTV High Heat Silicone Sealant Item 76A, 76, 76C, 76CT x Forms a flexible hea t-resistant seal x Does not require heat to cure...
  • Page 94 Appendix D particular purpose and suitable for user’s asserted, including warranty, contract, negligenc e or application. If this Rutland Fire Clay Company strict liability. product is defective within the warranty period stated above, your exclusive remedy and Rutlan AUTIONS Fire Clay Company’s sole obligation shall be, at Direct contact with uncured sealant irritates eyes...
  • Page 95 Appendix E CERAMIC STONES: LARGE (Grey or White) Burner 30 Model:Clear 40, 40H, TS, RS, LS, Tunnel Stand Alone 40 Bags: 2 Burner 45 Model: Clear 75, TS, RS, LS Minimal 75 Space Creator 75 Stand Alone 75 Clear 60x80/Tunnel Minimal 60x80 / Tunnel Clear 65x75 / Tunnel Bags: 3...
  • Page 96 Appendix E Burner 100 Models: Clear 110 and 130 Minimal 110 and 130 Stand Alone 110 and 130 Bags: 4 Model :Clear 110, RS, LS, TS and Tunnel Bags: 5 Model: Clear 130, RS, LS, TS and Tunnel Space Creator 120 Bags: 5...
  • Page 97 Appendix E Burner 135 Model: Clear 150 Stand Alone 150 Bags: 6 Model: Clear 150 TS / RS / LS Space Creator 150 Bags: 6 Model: Clear 170 Stand Alone 170 Bags: 6 Model: Clear 170, TS, RS, LS Space Creator 170...
  • Page 98 Appendix E Burner 160 Model: Clear 200 Bags: 8 Model :Clear 200 TS / RS / LS / Tunnel & Space Creator 200 Bags: 9...
  • Page 99 Appendix E CERAMIC STONE: SMALL ( Gray or White) Burner 30 Model: Clear 40 / 40H / TS / RS / LS / Tunnel Stand Alone 40 Bags: 2 Burner 45 Model: Clear 75, TS, RS, LS Minimal 75 Space Creator 75 Stand Alone 75 Clear 60x80 / Tunnel Minimal 60x80/ Tunnel...
  • Page 100 Appendix E Burner 100 Model: Clear 110 and 130 Minimal 110 and 130 Stand Alone 110 and 130 Bags: 6 Model: Clear 110, TS, RS, LS , Tunnel Bags: 7 Model: Clear 130, TS, RS, LS, Tunnel Space Creator 120 Bags: 8...
  • Page 101 Appendix E Burner 135 Model: Clear 150 Stand Alone 150 Bags: 8 Model: Clear 150, TS, RS, LS Space Creator 150 Bags: 10 Model: Clear 170 Stand Alone 170 Bags: 7 Model: Clear 170 , TS, RS, LS Space Creator 170...
  • Page 102 Appendix E Burner 160 Model: Clear 200 Bags: 11 Model: Clear 200 TS / RS / LS / Tunnel & Space Creator 200 Bags: 13...
  • Page 103 Appendix E LOGS ( 5 pcs.) 1 SET...
  • Page 104 Appendix E Burner 30 Model:Clear 40 /40H/ TS/ RS/ LS/ Tunnel Logs: Only Three Small Beige Embers: 1 Bag Burner 45 Model: Clear 75 TS, RS, LS Minimal 75 Space Creator 75 Stand Alone 75 Clear 60x80 / Tunnel Minimal 60x80/ Tunnel Logs:1 SET Beige Ember: 1 Bag...
  • Page 105 Appendix E Burner 100 Model: Clear 110 and 130 Minimal 110 and 130 Stand Alone 110 and130 Logs: (2) 5 pcs SET Beige Embers: 1 Bag Model: Clear 130 TS/RS/LS/Tunnel Clear 110 TS / RS / LS / Tunnel Logs: (2) 5 pcs SET Beige Embers: 2 Bags...
  • Page 106 Appendix E Burner 135 Model: Clear 150, TS, RS, LS, Tunnel Minimal 150 Stand Alone 150 Clear 170 Minimal 170 Logs: (2) 5 pcs SET Beige Embers: 2 Bags Model: Clear 170 TS/ RS/ LS/ Tunnel Logs: (3) 5 pcs SET...
  • Page 107 Appendix E Burner 160 Model: Clear 200 Logs: (3) 5 pcs SET Beige Embers: 2 Bags Model : Clear 200 TS/ LS/ RS/ Tunnel Logs: (3) 5 pcs SET Beige Embers: 2 Bags...
  • Page 108 Appendix E ENGLISH LONG BRANCH & SHORT BRANCH Burner 30 Model: Clear 40, 40H,TS, RS, LS,Tunnel Stand Alone 40 Branches :Only 5 SHORT BRANCHES Beige Embers: 1 Bag Burner 45 Model: Clear 75 TS/ RS/ LS Minimal 75 TS/ RS/ LS Space Creator 75 Stand Alone 75 Clear 75 Clear 60x80/ Tunnel...
  • Page 109 Appendix E Burner 100 Model: Clear 110 and130 Minimal 110 and 130 Stand Alone 110 and 130 Clear 110,TS, RS, LS, Tunnel Clear 130,TS, RS, LS, Tunnel Space Creator 120 Branches: 3 LONG BRANCHES & 9 SHORT BRANCHES Beige Embers: 2 Bags...
  • Page 110 Appendix E Burner 135 Model: Clear 150 TS, RS, LS Space Creator 150 Stand Alone 150 Branches: 4 LONG BRANCHES & 11 SHORT BRANCHES Beige Embers: 2 Bags Clear 150 & Stand Alone 150 Model: Stand Alone 170 Clear 170 TS, RS, LS Space Creator 170 Branches: 5 LONG BRANCHES &...
  • Page 111 Appendix E Burner 160 Model: Clear 200 Branches: 6 LONG BRANCHES & 10 SHORT BRANCHES Beige Embers: 2 Bags Model: Clear 200 TS / RS / LS / Tunnel Space Creator 200 Branches: 6 LONG BRANCHES & 12 SHORT BRANCHES Beige Embers: 2 Bags...

Table of Contents