Page 1
B AT T E R Y C H AR G E R BATTERY CHARGER Installation and User Manual...
Page 2
No other use is allowed without a written authorization supplied by ZIVAN S.r.l. ZIVAN S.r.l. will be not responsible for inaccuracies contained in this manual due to print or translation errors. ZIVAN S.r.l. has the right to make changes or improvements, also for the user interest, without prejudicing the essential characteristic of operation and safety.
Battery charger NG1 Installation and safety instructions Battery charger NG1 has been designed to provide safety and reliable. It is necessary to observe the following precautions in order to avoid damage to persons and to the battery charger: • Read the installation instructions contained in this Manual carefully. For further information put the Manual in a proper place.
Battery charger NG1 Operating principle The battery charger considerably affects battery life and performances, which is the main part of every electric vehicle. A non controlled traditional battery charger (rectifier) provides a simple direct AC/DC conversion. Disadvantages of this solution are: •...
Battery charger NG1 LED Indicator 100% RED LED shows that the battery is in the initial charging phase. YELLOW LED shows that the battery charger has reached 80% of charge. GREEN LED shows that the battery has reached 100% of charge.
Battery charger NG1 Auxiliary Contacts AUX1 AUX2 Technical Features: changeovers contacts 0,3A 125VAC 0,3A 110VDC 1A 30VDC faston 6,3 × 0,8 mm Connector: Unless otherwise stated, the auxiliary contacts provide the following functions: Section Function Description AUX1 Mains Presence When the equipment is switched on, the contact Normally Open (NO) CLOSES and instead the contact Normally Closed (NC) OPENS.
Battery charger NG1 Mechanical dimensions N.B. All dimensions are expressed in mm. Drilling details Ø6 Advised Installation N.B. All dimensions are expressed in mm. D01273-00...
Battery charger NG1 TECHNICAL FEATURES Ta=25°C unless otherwise specified Mains side Description Symbol Test Condition Value and/or Unit Range Supply Voltage 230 ± 10% Veff Frequency 50 ÷ 60 Absorbed Maximum Current P = P Aeff Inrush Current Vin = 230Veff <...
Battery charger NG1 General Description Symbol Test Condition Value and/or Unit Range ∆ Operating range of temperature from -20 to °C Maximum relative humidity Switching frequency 50 ± 5% η Efficiency At each operation > 85% condition Maximum size a×b×c Without connecting cable 300×160×80...
Battery charger NG1 Design, production and sales: ZIVAN SRL Via della Costituzione, 36 42028 Poviglio (RE) ITALIA Tel. +39 0522 960593 Fax +39 0522 967417 info@zivan.it SALES OFFICES ITALY FRANCE SWITZERLAND ZAPI SPA URMA SARL ASMO ENGINEERING AG Via Parma, 59 30, Rue de Morvan Silic 503 Glashütte, 58...