Connecting Cables - POSIFLEX Aura-5200E User Manual

Thermal printer
Table of Contents

Advertisement

and replace a new paper roll as illustrated above to prevent excessive paper
dust in the printer and consequently possibility for paper jam.
MULTIPLE INTERFACE ISSUE
For model Aura-5200E, there are 2 connectors for host connection through
RS232 or USB. Please always connect only one interface at a time.
Simultaneous multiple host connections could result in unexpected results!

CONNECTING CABLES

Serial Connection
All the external connectors are in the recessed area at the rear bottom, the
serial connector is a 9-PIN D sub Female connector between the USB
connector and the 3 pin power jack in this area. Apply the male connector of
RS232 cable to this port for serial application. The default protocol used in
serial connection is 19,200 bps, none parity, 8 data bits, 1 stop bit.
USB Connection-
The USB connector on Aura-5200E is a type B
USB connector at lower right position below the
serial port. Use the normal USB Cable as in the
right picture to connect the type A end to a
normal USB port of host system. Please visit our
web site http://www.posiflex.com or http://www.posiflex.com.tw for detailed
information of the USB driver installation if required. Please note that for
Aura-5200E, there must be no cable connection at the serial ports on the
printer.
Peripheral Connection
The peripheral controller is a 6-pin RJ11 type modular jack. With use of
Posiflex cash drawer cable come with cash drawer, this port can control a
Posiflex cash drawer CR-2000, CR-3100, CR-3200, CR-4000, CR-4100 or
CR-6310 series. If a Posiflex special split cable is used instead, this port can
Aura-5200E Connector Area
Type B
Type A
Normal USB
Plugs
Page 7

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aura-5200E and is the answer not in the manual?

Questions and answers

Table of Contents