CONTENTS RECOMMENDATIONS AND SUGGESTIONS INSTALLATION ELECTRICAL CONNECTION GETTING TO KNOW YOUR COOKER HOOD CARE AND CLEANING AFTER SALES SERVICE GUARANTEE KEY CONTACTS CE marking certifies that this appliance conforms to the following EEC directives:- Low Voltage Equipment Electromagnetic Compatibility Retention of this Instruction Book This Instruction Book must be kept handy for reference as it contains important details on the safe and proper use of the appliance.
• After having removed the packaging, check the condition of the appliance, if in any doubt, do not use and contact Hotpoint Service (see Key Contacts, back page). • The minimum safety distance between the hob and the extractor hood is 650 mm.
INSTALLATION Basic Hood Supply Voltage 220-240V Supply Frequency 50Hz Insulation Class Weight 12kg Motor 6/40K-A 6/50K-A 8BS/28K-A-P Dimensions Hood Type Technical Characteristics Power 150W 190W 205W...
Page 5
INSTALLATION Components Ref. Qty Ducted Version Hood Body, complete with: Controls, Light, Blower, Filters Telescopic Chimney comprising: Upper Section Lower Section Hood Body Fixing Brackets 7.2.1 Upper Chimney Section Fixing Brackets Right Air Outlet Grill Left Air Outlet Grill Reducer Flange ø 150-120 mm Wall Plugs Screws 4.2 x 44,4 Screws M4 x 25...
INSTALLATION Wall marking: • Draw a vertical line on the supporting wall up to the ceiling, or as high as practical, at the centre of the area in which the hood will be installed. • Draw a horizontal line at 650 mm above the hob for installation without the back panel, or at height H (height of the visible part of the panel) for installation with the back panel (see diagram above).
• Screw the two screws 12d supplied onto the brackets 7.1 • Hook the hood body onto bracket 7.1, centring it around the vertical line. • Using the adjusting screws 12d underneath the hood to level the hood body. DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø...
Upper chimney section • Slightly widen the two sides of the upper chimney and hook them behind the brackets 7.2.1, making sure that they are properly housed. • Secure the sides to the brackets using the 4 screws 12e supplied. Lower chimney section •...
WARNING: This appliance MUST be earthed. Connect to a 230 - 240V A.C. Supply only. • Connection to the electricity supply should be made via a properly earthed, readily accessible wall socket which is adjacent to and not more than 1.25m away from the appliance and capable of electrical isolation.
GETTING TO KNOW YOUR COOKER HOOD The Controls Light Switches the lighting system on and off. Motor Switches the extractor motor on and off. Speed Sets the operating speed of the extractor: Low Speed, used for a continuous and silent air change in the presence of light cooking vapour.
CARE AND CLEANING Before cleaning your cooker hood or carry out any maintenance, switch off and remove the plug from the socket to disconnect it from the electricity supply. CLEANING METAL SELF- SUPPORTING GREASE FILTERS The filters must be cleaned every 2 months of operation, or more frequently with heavy usage, and can be washed in a dishwasher.
CARE AND CLEANING CHARCOAL FILTER: REPLACING THE ACTIVATED CHARCOAL FILTER The filters are not washable and must be replaced after every 4 months of operation, or more frequently with heavy usage. • Remove the grease filters. • Remove the saturated activated charcoal filters as shown (A).
Hotpoint appliance than us - the manufacturer" As part of our commitment to you, all Hotpoint appliances have the added benefit of a fully inclusive parts and labour guarantee for the first 12 months. In addition to this you also have the advantage of free replacement parts for the first 5 years when fitted by a Hotpoint engineer.
All Hotpoint appliances carry a fully inclusive 12 month parts and labour guarantee as well as free replacement parts for the first 5 years (except microwaves, selected integrated appliances and cooker hoods, which have a one year guarantee) provided that they are fitted by a Hotpoint engineer.
Over 1200 trained specialists, directly employed by us, ensure that you can have complete confidence in both the appliances and services we offer. Repair Service and Information Desk (Open 8 to 8 Mon - Fri, 8 to 6 Sat, 10 to 4 Sun & Bank Holidays) Note: Our operators will require the following information: (Open 8-30 to 5-30 Mon - Fri &...
Need help?
Do you have a question about the HE61 and is the answer not in the manual?
Questions and answers