ERROR LOGIC & TROUBLESHOOTING continued

Platen Down Error

Occurs at cycle-start when the
platen fails to reach lower limit
position within 40 sec.
L1: PLATEN DOWN
L2:
Audio Alarm
Error
not self-
correcting
Press On/
Off key to
cancel.

Platen Up Error

Occurs at cycle-end when the
platen fails to reach upper limit
position within 40 sec.
L1: PLATEN UP
L2:
Audio Alarm
Error
not self-
correcting
Press On/
Off key to
cancel.
Part # 4517125 Rev. 2 (01/09/12)

Gas Ignition Error

Occurs when the ignition
feedback signal does not
respond after 4 tries.
L1: IGNITION ERROR
L2:
Audio Alarm
Error
not self-
correcting
Press On/
Off key to
cancel.

COMM Error

Occurs when
communication fails between
the main control and the motor
speed controller.
L1: COMM ERROR
L2:
Audio Alarm
Error
not self-
correcting
Press On/
Off key to
cancel.

Motor Overcurrent Error

Occurs when current to the motor
exceeds 4.8 amps, typically because
platen movement has encountered
mechanical resistance
L1: MOTOR
L2: OVERCURRENT
Audio Alarm
Error
not self-
correcting
Press Raise
Button to
cancel.

Motor Error

Occurs when the platen is in normal
up or down motion between limits,
but fails to generate 5 encoder
counts in any 1-second interval.
L1: MOTOR
L2: ERROR
Audio Alarm