Termination Settings; Setup - Samsung SCU-2370 User Manual

Positioning system
Hide thumbs Also See for SCU-2370:
Table of Contents

Advertisement

Communication Method Settings
Select a communication method for the camera.
#5
Communication Response Settings
Select a communication response method for the camera and controller: Response or No Response.
#6

Termination Settings

To prevent the attenuation of communication signals between the camera and controller, the items at
the end of line must be set up with the termination settings.
Camera Input Position
Terminal Resistance TX
Terminal Resistance RX
I
When terminating for RS-485: #8
When terminating for RS-422: #7, #8
Initialize
Initialize the system using the Initialize switch on the rear of the product.
Once initialized, all current settings will return to the factory default.
#10
I
If you do not set the Reset witch to OFF after resetting the system, all stored data will be lost when you restart the
system.
Function
Transfer Mode Switch
Function
Response Mode Switch
#7
ON
OFF
ON
ON
Initialize
ON
ON
RS-422(4Wire)
ON
Response
Do not use initialization
OFF
RS-485(2Wire)
OFF
No Response
#8
OFF
ON
OFF
English - 19