Sharp UP-600 Service Manual page 12

Sharp up-600 cash register service manual
Hide thumbs Also See for UP-600:
Table of Contents

Advertisement

Symbol/PartsCod)
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
2. UP-600 UTILITY TOOLS
1) OUTLINE
This Specification document describes the explanation about "POSU-
TILITYTOOL.EXE and "02FD.EXE".
"POSUTILITYTOOL.EXE"and "02FD.EXE" works on Windows 95/98
of PC and they have the following
Functions by connecting UP-600 with RS232.
POSUTILITYTOOL.EXE
: IPL of UP-600 Program Object
02FD.EXE
: All RAM Data Upload/Download
(PC software tool instead of the cur-
rent ER-02FD.)
3) PROCEDURE
3) -1. POS UTILITY
No
Procedure on P.C. side
1
Install the "POSUTILITYTOOL.EXE" on the P.C.
6
Connect the P.C. and the UP-600 (CH2) via RS232. (Fig 1)
2) CONNECTION
PC and UP-600 are connected by RS232.
Connect the CH2 port of the UP-600 to the RS-232 interface of the
PC.
PC
D-SUB 9pin - D-SUB 9pin
cable
RS232 Cable Connecting:
[PC]
D-sub 9pin
D-sub 9pin
7
7
/RS
4
4
/ER
SD
3
3
SD
1
1
/CD
GND
5
5
GND
RD
2
2
RD
6
6
/DR
8
8
/CS
9
9
/CI
No
Procedure on UP-600 side
2
Turn OFF the power.
3
Select "IPL Mode".
Set the "IPL Switch" (SW302) of the UP-600 to "ON".
4
Turn ON the power.
5
Starting of "IPL Mode".
The UP-600 displays
"IPL from Serial I/O"
IPL from Serial I/O
UP-600:CH2
D-SUB 9pin - modular RJ-45
conversion cable
[UP-600]
Moduler RJ45
CI
CD
7
1
/RS
4
2
/ER
S404
3
3
SD
1
4
5
5
GND
2
6
RD
S403
6
7
/DR
GND
VCC
8
8
/CS
(+5V)
9
(Open)
on
off
on
off
SW302

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Up-700Dp-750

Table of Contents