  • Page 2: Table Of Contents

    8. Use only lubricants and fuel recommended in this manual. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 2 For Engine technical questions, please call 1-800-520-0882.
  • Page 3: Setup

    6. Keep all spectators at least six feet any non-insulated conductive object. from the Engine during operation. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 3 For Engine technical questions, please call 1-800-520-0882.
  • Page 4 38. Keep hands and feet away from moving parts. Do 26. Use only accessories that are recommended not reach over or across generator while operating. by Harbor Freight Tools for your model. Accessories that may be suitable for one 39. Before use, check for misalignment or binding...
  • Page 5: Service Precautions

    If unreadable or missing, contact Harbor Freight Tools for a replacement. SAVE THESE INSTRUCTIONS. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 5 For Engine technical questions, please call 1-800-520-0882.
  • Page 6: Specifications

    Available accessories Wheel kit (sold separately) Item 68525 - The emission control system for this Generator’s Engine is warranted for standards set by the U.S. Environmental Protection Agency and by the California Air Resources Board (also known as CARB). For warranty information, refer to the last pages of this manual.
  • Page 7 Receptacle (120 volt or 240 volt) that is compatible with the electrical characteristics and rated capacities of the tools and equipment being used. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 7 For Engine technical questions, please call 1-800-520-0882.
  • Page 8: Operation

    Control Panel to a grounding rod (not included) that has been driven at least 24 inches deep into the earth. The grounding rod must be an earth-driven copper or brass rod (electrode) which can adequately ground the Generator. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 8 For Engine technical questions, please call 1-800-520-0882.
  • Page 9: Initial Set Up/Assembly

    Solenoid Seal Part Description Main Jet 3000-6000 ft. Main Jet 6000-8000 ft. Bolt Seal Solenoid Fuel Cup Seal Screws Solenoid Seal For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 9 For Engine technical questions, please call 1-800-520-0882.
  • Page 10 (The SAE Viscosity Grade chart on page 17 in the Service section shows other viscosities to use in different average temperatures.) For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 10 For Engine technical questions, please call 1-800-520-0882.
  • Page 11: Using The Generator

    The maintenance break-in period will last about 20 hours of use. After this period: • Change the engine oil. Under normal operating conditions subsequent maintenance follows the schedule explained in the SERVICE section. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 11 For Engine technical questions, please call 1-800-520-0882.
  • Page 12: Starting The Engine

    IMPORTANT: Allow the engine to run at no load for five minutes with no load after each start-up so that the engine can stabilize. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 12 For Engine technical questions, please call 1-800-520-0882.
  • Page 13: Connecting Electrical Loads

    2. Adjust the plugs so the loads are shared across outlet circuits. To achieve rated output from the generator, distribute loads over outlets. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 13 For Engine technical questions, please call 1-800-520-0882.
  • Page 14 Furnace Fan - 1/2 HP 1400 there are no additional start-up watts. Space Heater 1800 Window AC - 10,000 BTU 1200 For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 14 For Engine technical questions, please call 1-800-520-0882.
  • Page 15: Stopping The Engine Under Normal Conditions

    2. Turn the Engine Switch off. START 3. Close the Fuel Valve. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 15 For Engine technical questions, please call 1-800-520-0882.
  • Page 16: Maintenance

    Replace fuel line if necessary Service more frequently when used in dusty areas. These items should be serviced by a qualified technician. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 16 For Engine technical questions, please call 1-800-520-0882.
  • Page 17: Checking And Filling Fuel

    3. Install the new filter or the cleaned filter. Secure the Air Cleaner Cover before use. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 17 For Engine technical questions, please call 1-800-520-0882.
  • Page 18: Spark Plug Maintenance

    For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 18 For Engine technical questions, please call 1-800-520-0882.
  • Page 19: Troubleshooting

    4. Have qualified technician diagnose/ mis-adjusted or stuck. repair ignition system. Follow all safety precautions whenever diagnosing or servicing the equipment or engine. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 19 For Engine technical questions, please call 1-800-520-0882.
  • Page 20 Follow all safety precautions whenever diagnosing or servicing the equipment or engine. For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 20 For Engine technical questions, please call 1-800-520-0882.
  • Page 21: Parts List And Diagram

    Guide, Seal Clamp The following parts are only on Tappet, Valve Pipe, Exhaust Lifter Sub, Valve Bolt Item 68525 (EPA/CARB version) Plate Sub, Lifter Stopper Tank, Fuel 169 Bolt Bolt, Valve Adjusting Sleeve, Fuel Tank Rubber 170 Collector, Fuel Steam...
  • Page 22: Assembly Diagram

    Assembly Diagram Note: Parts 169 - 173 are only on Item 68525 (EPA/Carb version) For Generator technical questions, please call 1-800-444-3353. Item 68525 / 68530 Page 22 For Engine technical questions, please call 1-800-520-0882.
  • Page 23: Warranty

    Limited 90 Day Warranty Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that this product is free from defects in materials and workmanship for the period of 90 days from the date of purchase.
  • Page 24 Harbor Freight Tools Emission Control Service and Maintenance Defects Warranty Provisions Component parts which are not scheduled for replacement as required maintenance or are scheduled only for regular inspection to the effect Length of Coverage of “repair or replace as necessary” are warranted for the warranty HFT warrants to a first retail purchaser and each subsequent period.