Event code
Description
Cleaning failure. Cleaning process could not
61
be performed.
62
Cleaning tape expired.
Invalid cartridge. Drive has rejected the
63
cartridge as invalid.
Invalid cleaning cartridge. Drive has rejected
64
the cartridge as invalid.
Invalid upgrade cartridge. Drive has rejected
65
the cartridge as invalid.
66
Diagnostic tape write protect.
67
Incompatible medium
70
SCSI message error
71
SCSI parity error
72
SCSI invalid message
73
SCSI: overlapped command attempt
74
SCSI: echo buffer overwritten
Movement retry. Robotics movement did not
80
succeed but was successful on a retry.
81
Drive sled fan alert. Fan motion has stopped.
82
Clean request from the tape drive
HP StorageWorks 1/8 G2 Tape Autoloader User and service guide
Details and Solution
Check cleaning tape and exchange if
necessary.
Retry the operation.
Exchange the cleaning tape.
Verify that the cartridge generation and
technology are supported by the device.
See
Tape
cartridges" on page 43.
Retry the operation.
If problems persist, exchange the data
cartridge.
Retry the operation.
If problems persist, exchange the data
cartridge.
The diagnostic test needs to write data but
the tape being used for the test is write
protected. Ensure that the device has a tape
that is not write protected for use during the
diagnostic test.
The drive tried to read or write data from a
tape from an incompatible LTO generation.
For compatibility information see
read
compatibility, page 47.
Check the SCSI cable connection and verify
that the maximum cable length is not
exceeded. Verify that the SCSI bus is properly
terminated.
The application software made an illegal
request.
Recovered error move operation. No action
required. Occasional retries are normal
operation.
Check the tape drive fan on the Autoload-
er back panel to see whether the fan is
operational and not obstructed.
NOTE:
Fan only operates when cooling is
required.
Clean the tape drive using a valid cleaning
tape.