Communication (General Purpose Serial Interface) - Sharp IV-S51M Instruction Manual

Image sensor camera
Table of Contents

Advertisement

Communication (General Purpose Serial Interface)

The IV-S51M can communicate with a personal computer that transmits commands and receives
responses to process measurement execution commands.
List of processing function
1. Outline
• The following functions and commands are supported by IV-S51M.
Item
Measurement
execution
Result data
reading
Lighting
control
Self-diagnosis
2. List of commands
Category
Executing
measurement
Reading
measurement
data
Controlling
lighting
Functions
Executes measurement programs for specified
object types and outputs the numeric value results.
• Outputs the numeric value result of the last
measurement (measurement is not executed).
• Monitoring illuminance
• Light level automatic adjustment
Control lighting power source
• Setting up lighting control system
• Lighting ON / OFF
• Reading / writing light volume
• Reading / writing EEPROM light volume
Diagnosing hardware of image processing board
Item
Code
Measurement
0010
execution 1
Measurement
0011
execution 2
Measurement
0012
execution 3
Measurement
0110
data reading 1
Measurement
0111
data reading 2
Measurement
0112
data reading 3
Illuminance
0118
monitor
Functions
• Outputs the numeric value result of the
executed measurement.
• Maximum 512 bytes
• Outputs the numeric value result of the
executed measurement.
• If the volume of the data exceeds 512 bytes,
it will be divided into packets.
• Outputs the numeric value result of the last
measurement.
• If the volume of the data exceeds 512 bytes,
it will be divided into packets.
• Outputs the numeric value result of the last
measurement.
• Maximum 512 bytes
• Outputs the numeric value result of the last
measurement.
• If the volume of the data exceeds 512 bytes,
it will be divided into packets.
• Outputs the arithmetic result (double precision
floating decimal point) of the last measurement.
• If the volume of the data exceeds 512 bytes,
it will be divided into packets.
Executes illuminance monitor to provide the
measured light level and the evaluation result.
6 - 1
Communication
port
COM
COM
COM
I/O Link
COM

Advertisement