6. CONNECTION
OF POWER
FAILURE
UNIT
Power
Failure
Unit (PFU) is optional
equipment
which,
in case of power
failure,
directly
connects
CO/PBX
lines and
Single
Line Telephones.
0
Wall mounting
method
for PFU
@
Remove a PFU cover.
@
Install one wood screw on the wall remaining
about 5/16 inches of the screw length unscrewed.
@
Hook the mounting
hole provided
at the top of the PFU to the on-wall
installed
wood screw, then fasten the wood screw
completely.
@
Install two wood screws on the wall through
the two respective
mounting
holes provided
at the bottom
of the PFU.
l
Connection
of PFU
(1)
Connect
the connectors
labelled
"FROM
COL"
(COL
1 to 4) and located
inside the power failure
unit to the respective
central office lines.
(2) Connect
COL Nos. 1, 2, 3 and 4 inside the key service unit to the connectors
(4 places from the top) labelled
"TO COL
(KSU)"
and located
inside the power failure unit, respectively.
(3)
Connect
the connectors
(4 places from the top) located
on the card of the SLT card (right side card), which is set inside
the key service unit, to the connectors
labelled
"FROM
SLT-LC(KSU)"
and located inside the power failure
unit, respec-
tively.
(4)
Connect
the connectors
(TELs 1 to 4) labelled
"TO SLT"
and located inside the power failure unit to the respective
single
line telephones.
These connectors
are allotted,
in order from the top, Extensions
Nos. 30,31,32
and 33.
(5)
Connect
the two screw terminals
labelled
"PFU"
and located
inside the key service unit to the respective
two screw
terminals
labelled
"TO KSU"
and located inside the power failure
unit.
(6)
Remove
the clamp
plate, insert the cords, then reinstall
the clamp plate over the cords and secure into place with the
screw.
Note:
That when power failure occurs the COLs correspond
to EXTs as shown below.
COL I-+ EXT. No. 30
COL 2 -+ EXT. No. 31
COL 3 + EXT. No. 32
COL 4 + EXT. No. 33