Firex FADCM User Manual

Firex FADCM User Manual

Ionization smoke / carbon monoxide alarm
Hide thumbs Also See for FADCM:

Advertisement

SERIES 12000 IONIZATION SMOKE /
CARBON MONOXIDE ALARM
MODEL FADCM (12000 Series): 120 V AC WITH 9V BATTERY
MODEL FADCM-B (12200 Series): DC ONLY WITH 9V BATTERY
MODEL GCM (12400 Series): 120 V AC ONLY
PLEASE READ AND SAVE THIS ENTIRE MANUAL
Installer: Please leave this manual with the product
Single or multiple station Smoke/CO alarm
Electrical rating Models FADCM and GCM: 120V AC, 60Hz, 0.06amp
Model FADCM includes 9V battery back-up
Single station Smoke/CO alarm
Model FADCM-B includes 9V battery
About This Combination Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
Specifications and Important Product Information . . . . . . . . . . . . . . . . . . . . . . . .1
Where to Install This Smoke/CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3
How To Install This Smoke/CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
1. Battery Power (DC) and DC Interconnect . . . . . . . . . . . . . . . . . . . . . . . . . . .4
2. Installing an AC With Battery Back-Up Alarm . . . . . . . . . . . . . . . . . . . . . . . .4
3. Interconnecting AC Only and AC/DC Alarms . . . . . . . . . . . . . . . . . . . . . . . .5
If the Alarm Sounds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Troubleshooting the CO Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 & 8
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Symptoms of CO Poisoning and Sources of CO in the Home
Testing and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Service and Warranty Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
The following symbols identify the most important safety messages in
this manual.
DANGER
WARNING
CAUTION
About this Smoke/Carbon Monoxide Alarm:
This combination Smoke/CO alarm is designed to detect smoke and carbon monox-
ide gas. It is NOT designed to detect fire or any other type of gas. If this Smoke/CO
alarm sounds its alarm horn, DO NOT assume that it is a false alarm. The alarm
horn requires your immediate action.
Individuals with medical problems may consider using warning devices which provide
audible and visual signals for carbon monoxide concentrations under 30ppm.

SPECIFICATIONS AND IMPORTANT PRODUCT INFORMATION

Product Features
• Monthly Self-Test: Approximately every 30 days this alarm performs a silent
internal system test to verify sensor operation utilizing True Gas Testing. True Gas
Testing assesses the service life of the CO sensor. Traditional CO alarms test the
sensor by simulating an alarm condition electrically. This is the first CO sensor that
runs a diagnostic test by generating a very small and harmless amount of hydro-
gen gas. If the sensor is working properly, it WILL NOT chirp. If the alarm chirps
during the monthly self-testing, it is indicating a problem with the unit. Refer to the
charts on pages 7 and 8 for the appropriate actions to take should this occur. You
must still test the alarm weekly to verify proper horn operation.
• Trigger Alarm Locator™ (TAL™): Most interconnect tests trigger all alarm horns
simultaneously for the duration of the test. This unique system alternates between
a 10 second ALL ON cycle and a 50 second cycle where only the initiating alarm
is sounding.
• Alarm Controlled Interconnect Test: In an interconnected system, this feature
will alarm the local unit first, then quiet the local unit while the remote units alarm.
• Smart Quiet™ Low Battery 1: Allows the homeowners to silence the low battery
chirp for up to 10 hours, giving them time to go back to sleep and/or purchase a
fresh replacement battery.
• Smart Quiet™ Low Battery 2: Indicates the battery no longer has enough volt-
age to adequately protect in the event of a power outage or a battery-only instal-
lation. The Smart Quiet™ feature will no longer silence the chirp. THE BATTERY
MUST BE REPLACED IMMEDIATELY.
Required Power Supply
• Model FADCM requires constant 120-volt, AC power and a working 9-volt battery to
operate properly. The alarms WILL NOT work if AC power is not connected or has
failed or been interrupted for any reason and in the case of FADCM, the battery is
removed, drained or improperly connected. DO NOT use any other kind of battery
except as specified in this manual.
• Model GCM requires constant 120-volt AC power to operate properly.
• Model FADCM-B operates on battery power only. Having only one source of power is
less reliable than having two different power sources. If the battery is too weak to
power the alarm, or is removed from the alarm, the alarm will not protect you from haz-
ardous conditions within your home. Make sure a battery-only installation complies
with your local codes and regulations. Check with your local fire department or building
code enforcement department if you are unsure of rules.
NOTE: AC/DC alarms offer added protection in the event of a power failure or a
drained battery.
Smoke / CO Alarm
BACK-UP

TABLE OF CONTENTS

When you see this symbol, be aware that if the
message is ignored, the hazard WILL result in
SEVERE bodily injury or death.
When you see this symbol, be aware that if the
message is ignored, the hazard CAN cause
SEVERE bodily injury or death.
When you see this symbol, be aware that if the
message is ignored, the hazard CAN or WILL
cause MINOR bodily injury.
WARNING
1
110-1124D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FADCM and is the answer not in the manual?

Questions and answers

Summary of Contents for Firex FADCM

  • Page 1: Table Of Contents

    The alarms WILL NOT work if AC power is not connected or has failed or been interrupted for any reason and in the case of FADCM, the battery is removed, drained or improperly connected. DO NOT use any other kind of battery except as specified in this manual.
  • Page 2: Where To Install This Smoke/Co Alarm

    AGENCY ALARM PLACEMENT RECOMMENDA TIONS Invensys Controls Americas recommends complete coverage protection achieved by installing a smoke alarm in every room of your home. The National Fire Protection Association’s (NFPA) minimum requirement, as stated in Standard 72, Chapter 2, reads as follows: “2-2.1.1.1 Smoke detectors shall be installed outside of each separate sleeping area in the DINING...
  • Page 3 Models FADCQ and COQ8 are still compatible with all existing FireX AC and AC/DC smoke alarms. • This Smoke/CO alarm should be installed only by a licensed qualified electrician.
  • Page 4: How To Install This Smoke/Co Alarm

    8. Test the alarm. See “TESTING AND MAINTENANCE” for details. Installing With a Junction Box Models FADCM (12000 Series) and GCM (12400 Series) CAUTION Do not use super glue or silicon caulk on or near the alarm! Fumes from these products can coat and permanently damage the sensor.
  • Page 5: Interconnecting Ac Only And Ac/Dc Alarms

    FADCM, GCM, FADC, TPCI, AD, ADC, PAD, FPAD, G, GC, or PG40 smoke alarms, and as many as 6 FireX model ADH heat alarms and/or COE or COEA CO alarms for a total of not more than 18 interconnected devices.
  • Page 6: To Temporarily Silence An Alarm

    IF THE ALARM SOUNDS If Your Smoke Alarm Sounds (and you are not testing it) WARNING IF BOTH RED LIGHTS ARE FLASHING AND THE HORN SOUNDS 3 ALARMS APPROXIMATELY EVERY FOUR SECONDS, IT INDICATES THE PRESENCE OF SMOKE WHICH CAN INDICATE THE PRESENCE OF FIRE. YOU MUST QUICKLY DO THE FOLLOWING: 1.
  • Page 7: Chart : Understanding The Led Lights And Horn Patterns

    Indicates older CO alarms without Smart Interconnect are Interconnected CO sharing the same interconnect line and cannot distinguish alarms sound with between alarm signals for smoke or CO. Replace with smoke alarms when model COE, COEA or FADCM alarms. Smart Button is pushed to test units.
  • Page 8 Smart Button. SOLUTION PROBLEM The horn beeps once, The alarm is operating properly. The FireX patented Horn then two beeps, then Ramp-Up feature lets you start the test sequence and three beeps, pauses, and move away from the unit before the full alarm horn then sounds the full sounds.
  • Page 9: Important Safety Information

    IMPORTANT SAFETY INFORMATION Fire Safety Tips These guidelines will assist you in the event of a fire. However, to reduce the chance that fires will start, practice fire safety rules and prevent hazardous situations. • Develop family escape plans, discuss them with ALL household members, and practice them regularly.
  • Page 10: Cleaning

    El Paso Texas 79906 Mississauga Ontario L5L 5Y7 If the Smoke/CO alarm is no longer under warranty, have a licensed electrician replace the Smoke/CO alarm immediately with a comparable FireX brand alarm. For Technical Support: Phone: (800) 445-8299 Email: technicalservice@invensys.com Website: www.invensyscontrols.com...