Mitsubishi Electric Mr. Slim PKA-RP HAL Operation Manual

Indoor unit

Advertisement

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric Mr. Slim PKA-RP HAL

  • Page 2: Table Of Contents

    2006/66/EC Article 20 Information for end-users and Annex II. Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and/or reused. This symbol means that electrical and electronic equipment, batteries and accumulators, at their end-of-life, should be disposed of separately from your household waste.
  • Page 3: Parts Names

    2. Parts Names ■ Indoor Unit PKA-RP·HAL PCA-RP·KA PCA-RP·HA PSA-RP·GA Fan speed 3 speeds + Auto 4 speeds + Auto 2 speeds 2 speeds Vane Auto with swing Auto with swing Manual Manual Louver Manual Manual Manual Auto with swing Filter Normal Long-life...
  • Page 4: Operation Section

    2. Parts Names ■ Wired Remote-Controller “Sensor” indication Display Section Displayed when the remote controller sensor is used. Day-of-Week For purposes of this explanation, Shows the current day of the week. all parts of the display are shown. During actual operation, only the Time/Timer Display relevant items will be displayed.
  • Page 5 2. Parts Names ■ Wireless Remote-Controller Transmission area Transmission indicator Remote controller display Timer indicator * For explanation purposes, all of the items that appear in the display are shown. * All items are displayed when the Reset but- ton is pressed. Operation areas ON/OFF button Set Temperature buttons...
  • Page 6: Screen Confi Guration

    3. Screen Confi guration <Screen Types> Function Selection of remote For details on setting the language for the remote controller display, refer Set Day/Time controller to section 8. Function Selection. TIME SUN The initial language setting is English. ● Function Selection of remote controller: Set the functions and ranges available to the remote controller (timer functions, operating restrictions, etc.)
  • Page 7 5. Operation 5.2. Mode select 5.3. Temperature setting ■ ► To decrease the room temperature: ) button 2 and select the opera- Press the operation mode ( button 3 to set the desired temperature. tion mode 2. Press The selected temperature is displayed 3. Cooling mode Drying mode ►...
  • Page 8: Timer

    5. Operation 5.5. Airfl ow direction setting 5.6. Ventillation For LOSSNAY combination <To Change the Airfl ow’s Up/Down Direction> (PCA-KA, PKA-HAL) 5.6.1. For Wired Remote-controller ■ With the unit running, press the Airfl ow Up/Down button 6 as necessary. To run the ventilator together with the indoor unit: •...
  • Page 9 6. Timer 2. Press the Timer Menu button 2, so that the “Set Up” appears on the <How to View the Weekly Timer Settings> screen (at 2). (Note that each press of the button toggles the display between “Set Up” and “Monitor”.) Timer Settings 3.
  • Page 10 6. Timer <How to Set the Simple Timer> <To Turn Off the Simple Timer...> Press the Timer On/Off button 9 so that the timer setting no longer ap- Timer Setting pears on the screen (at 7). Action (On or Off) AFTER * “—...
  • Page 11 6. Timer 6.1.3. Auto Off Timer <To Turn Off the Auto Off Timer...> ● ■ Hold down the Timer On/Off button 9 for 3 seconds so that “Timer This timer begins countdown when the air conditioner starts and shuts Off” appears (at 6) and the timer value (at 7) disappears. the air conditioner off when the set time has elapsed.
  • Page 12: Other Functions

    7. Other Functions 7.1. Locking the Remote Controller Buttons (Opera- <How to Lock the Buttons> tion function limit controller) 1. While holding down the Filter button 4, press and hold down the ON/ ■ If you wish, you can lock the remote controller buttons. You can use OFF button 1 for 2 seconds.
  • Page 13: Function Selection

    8. Function Selection Function selection of remote controller The setting of the following remote controller functions can be changed using the remote controller function selection mode. Change the setting when needed. Item 1 Item 2 Item 3 (Setting content) 1. Change Language Language setting to display •...
  • Page 14 8. Function Selection [Function selection fl owchart] Normal display (Display when the air conditioner is not running) Hold down the button and press the button for 2 seconds. Setting language (English) Press the operation mode button. Hold down the button and press the button for 2 seconds.
  • Page 15 8. Function Selection [Detailed setting] [4]-3 Mode selection setting [4]-1 CHANGE LANGUAGE setting (1) Remote controller main/sub setting ON/OFF] button D. The language that appears on the dot display can be selected. • To switch the setting, press the [ MENU] button G to change the language.
  • Page 16 8. Function Selection [Dot display table] Selecting language English German Spanish Russian Italian Chinese French Japanese Waiting for start-up Operation mode Cool Heat Auto Auto(Cool) Auto(Heat) Ventilation Stand by (Hot adjust) Defrost Set temperature Fan speed Not use button Check (Error) Test run Self check Unit function selection...
  • Page 17: Emergency Operation For Wireless Remote-Controller

    9. Emergency Operation for Wireless Remote-controller Starting operation • To operate the cooling mode, press the button D for more than 2 seconds. button C for more than 2 • To operate the heating mode, press the seconds. Stopping operation button D or the button C for more •...
  • Page 18: Care And Cleaning

    10. Care and Cleaning ■ PCA-RP·KA ■ PCA-RP·HA RP71 → 3 pieces RP125 → 4 pieces Open the intake grille. ►Cleaning the oil fi lter (PCA-RP·HA Series) Hold the knob on the fi lter then pull the fi lter up in the direction of an arrow. To 1) Removing the oil fi...
  • Page 19: Trouble Shooting

    11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) ■ Air conditioner does not heat or cool well. Clean the fi lter. (Airfl ow is reduced when the fi lter is dirty or clogged.) ■ Check the temperature adjustment and adjust the set temperature. ■...
  • Page 20: Specifi Cations

    11. Trouble Shooting Having trouble? Here is the solution. (Unit is operating normally.) ■ Draining water or motor rotation sound is heard. When cooling operation stops, the drain pump operates and then stops. Wait approximately 3 minutes. ■ Noise is louder than specifi cations. The indoor operation sound level is affected by the acoustics of the particular room as shown in the following table and will be higher than the noise specifi...
  • Page 21 12. Specifi cations Model PSA-RP71GA PSA-RP100GA PSA-RP125GA PSA-RP140GA Power source(voltage <V>/Frequency<Hz>) ~/N 230/50 0.15/0.15 0.24/0.24 0.28/0.28 0.36/0.36 Rated Input(Indoor only) <kW> 0.66/0.66 1.06/1.06 1.23/1.23 1.59/1.59 Rated Current(Indoor only) <A> Heater <kW> 1900 Dimension(Height) <mm> Dimension(Width) <mm> Dimension(Depth) <mm> Fan airfl ow rate(Low-High) <m /min>...
  • Page 22 Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN BG79U612H03 Printed in Japan...