Phoenix 1200 Owner's Manual

Phoenix 1200 Owner's Manual

Portable desiccant dehumidifier

Advertisement

Quick Links

Owner's Manual — Phoenix 1200
The Phoenix 1200 Portable Desiccant Dehumidifier offers the
finest in air-drying equipment; however, this machine can only
provide maximum service if properly installed, operated, and
maintained.
This manual is provided to acquaint you with the dehumidifier
so that installation, operation and maintenance can proceed
successfully. Ultimate satisfaction depends on the quality of
installation and a thorough understanding of this equipment.
The dehumidifier is built around tested engineering principles
and has passed a thorough inspection for quality of
workmanship and function.
The Phoenix 1200 Desiccant Dehumidifier
• 900 CFM process airflow
• 300 CFM reactivation airflow
• 12" Inlet
• 8" Reactivation Outlet
• Dual 8" Process Outlets
• 230 Volt single phase:
- User selectable 25 or 40 amp draw
- All the standard 120 volt outlets available for
Phoenix air movers
• Fits easily through doors, up truck ramps and in SUVs
• Quiet operation
- Constant run mode or humidistat controlled mode
• Hi-Lo handles for easy lifting
• External filters and fuses for simple maintenance
• Tough weather resistant design
• Operating Range -10ºF to 120ºF
Specifications subject to change without notice.
Toll-Free 1-800-533-7533
4201 Lien Rd.• Madison, WI 53704
Desiccant Dehumidifier
Installation, Operation & Service Instructions
Read and Save These Instructions
1
www.UsePhoenix.com • sales@UsePhoenix.com
PN 4028000
TS-449b
02/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1200 and is the answer not in the manual?

Questions and answers

Summary of Contents for Phoenix 1200

  • Page 1 Owner’s Manual — Phoenix 1200 Desiccant Dehumidifier Installation, Operation & Service Instructions Read and Save These Instructions The Phoenix 1200 Portable Desiccant Dehumidifier offers the finest in air-drying equipment; however, this machine can only provide maximum service if properly installed, operated, and maintained.
  • Page 2: Table Of Contents

    The dehumidifier is designed with the two air streams flowing INTERRUPTER. in opposite directions (counter flow) thereby maximizing the • DO NOT use the Phoenix 1200 as a bench or table. energy efficiency of the equipment. • It must always be used in the upright position.
  • Page 3: Installation Instructions

    Proper installation of this dehumidifier is very important for maximum service and performance. Refer to “Installation Instructions for the Phoenix 1200 Dehumidifier” label on top 4.1 Airflow of machine above control panel. The dehumidifier uses two distinct air streams. This eliminates the requirement to “balance”...
  • Page 4: Make-Up Air Vent

    7 Dehumidifier Maintenance 5.3 Make-Up Air Vent A make-up air vent is located under a hood at the top of the Instructions inlet filter box. When used in the space to be conditioned, the vent should be fully closed. If the dehumidifier is placed outside the conditioned space, the vent should be fully 7.1 General Maintenance opened to allow for make-up air into the inlet.
  • Page 5: Drive Motor

    To re-install media, reverse the above procedure. for Phoenix. Normally, the seals will not require service or replacement. However, should damage occur, or if poor performance as the result of an air leak is suspected, the...
  • Page 6: Troubleshooting

    Note: The direction of the perimeter seal should be so the outside overlap is pointing in the direction of rotation. (If you have questions, contact Phoenix.) 5. Remove the old divider seal. Install new divider seal using original metal screws and seals retainers.
  • Page 7: Service Parts

    10 Service Parts Description Part Number Disconnect Switch 4028301 Control Switch 4028302 High/Low Switch 4028303 Humidistat 4028126 Humidistat Knob 4028127 Fuse 1932035 Fuse Holder 4028304 Control Transformer 4027307 Indicator Lamp 4028128 Relay 4028306 Reactivation Heater 4028307 Fan Motor 4028308 System Fan 4028309 Motor Pulley 4028144...
  • Page 8: Wiring Diagram

    11 Wiring Diagram Toll-Free 1-800-533-7533 www.UsePhoenix.com • sales@UsePhoenix.com...
  • Page 9: Warranty

    Limitations and Exclusions: If any Phoenix 1200 part is repaired or replaced, the new part shall be warranted for only the remainder of the original warranty period applicable thereto (but all warranty periods will be extended by the period of time, if any, that the Phoenix 1200 is out of service while awaiting covered warranty service).