INDICATOR LIGHTS

Tank control system light
This dehumidifier has a special device to control
correct operation.
A red indicator light on the control panel comes
on to warn the user when:
1. the tank is full: empty the tank
2. the tank is missing: reposition the tank
3. the tank is incorrectly positioned: position the
tank correctly
4. with continuous drain:
the hose is blocked or sloping upwards (water
is still draining into the tank)
remove the obstruction
When the cause has been removed, the light goes
off and the appliance resumes operation.
Dehumidifying standby/low-tem-
perature operation light
The light comes on:
1) To indicate the appliance is in standby for
about three minutes before start-up. This
device protects the compressor from starting
and stopping too often.
2) To indicate low temperature operation. When
the temperature in the room is too low, the
low temperature operation electronic device
trips.This operates the appliance with
alternate cycles of dehumidifying and fan only
to avoid the formation of ice.
For frequent use in particularly cold rooms,
you are recommended to raise room
temperature, even if only slightly.
This ensures that the dehumidifier is
operating
under
improving its performance and accelerating
dehumidification.