Start-Up Procedures—900IF Iron Filter, Cont.
Start the Regeneration Cycle
Step 4
A.
Press and hold the Regenerate button until the controller indicates 01 (flashing). The
regeneration cycle begins. During regeneration, water bypasses the appliance to allow iron
and sediment to wash down the drain through the following six-step process:
1. First Upflow Backwash—A rapid upflow of water flushes out the media bed.
2. Regeneration—Regenerant is drawn out of the solution cabinet and up through the
3. Slow Rinse—A slow upflow rinse process that flushes out the regenerant and iron.
4. Second Upflow Backwash—This upflow backwash flushes out any remaining
5. Downflow Clean Water Refill—Filtered water is directed to the solution cabinet to
6. Return to Service—Regeneration is complete after approximately 45 minutes and the
Program the Regeneration Cycle
Step 5
A.
To ensure reliable performance and optimum efficiency, program the regeneration cycle to
occur every one to fourteen days. Use the following worksheet to determine the appropriate
frequency for scheduling the regeneration cycle for your appliance. Use the example as a
guide.
B.
On the controller, set the frequency and time of day for regeneration to occur. Follow the
instructions provided in Setting the Controller.
Total Iron
+ Manganese*
+ Sulfur
= Total compensated ppm
x Gallons per day for one person
= ppm per person per day
x Number of people in household
= Daily ppm capacity
Iron filter capacity
 Daily ppm capacity
= Frequency of regeneration
Set regeneration frequency
*If manganese is unknown, multiply the iron and sulfur total by 1.15 to adjust total compensated ppm.
WaterBoss Filter Owner's Manual
media tank, cleaning the media bed and releasing accumulated iron and hydrogen
sulfide.
regenerant and sediment from regeneration.
prepare the regenerant for the next regeneration sequence.
appliance is returned to Service position. The controller will display a number between
01 to 14. This number is the days to next regeneration.
Regeneration Cycle Frequency Worksheet
Your Water
_____ ppm x 1 =
_____ ppm x 3 =
_____ ppm x 5 =
=
=
=
@
____ ppm
2.4 ppm x 1 =
____ ppm
0.2 ppm x 3 =
____ ppm
1.0 ppm x 5 =
____ ppm
75 gal
____ ppm
____ people
____ ppm
5600 ppm
____ ppm
____ days
____ days
6/13/2012
Example
2.4 ppm
0.6 ppm
5.0 ppm
8.0 ppm
75 gal
600 ppm
3 people
1800 ppm
5600 ppm
1800 ppm
3.1 days
3 days
18

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 900IF and is the answer not in the manual?

Questions and answers

John Uss
January 30, 2025

How is the greensand removed from the iron filter. How much greensand is needed tto activate the unit

Glenn Lapham
February 5, 2025

What do all the different codes mean, HO, 01, 02, etc? I know what the E codes are, it’s in the manual.

This manual is also suitable for:

900cf900nf

Table of Contents

Save PDF