BYPASSING ZONES (cont'd)
Bypassing
NOTE: Ask your installer if your system was set up to
System
allow system zones and system outputs to be bypassed.
Supervisory
Your system may allow you to bypass certain "system zones"
Zones
which monitor various aspects of system status and certain
system outputs which annunciate system status. These zones
and outputs are listed below. This feature is used to disable the
monitoring of one or more system zones or to disable the
operation of one or more system outputs when, for example, the
system is to be serviced or tested. If enabled, this feature can
only be used by a master user.
¥
¥
¥
¥
¥
¥
¥
¥
zone #970: monitors the supervision status of the bell 1
output (if enabled at installation time). Bypassing this zone
disables the operation and supervision of the bell 1 output.
zone #971: monitors the supervision status of the bell 2
output (if enabled at installation time). Bypassing this zone
disables the operation and supervision of the bell 2 output.
zone #972: monitors the panel's field wiring to determine if a
short to earth ground exists. Bypassing this zone disables
earth ground fault monitoring.
zone #973: monitors devices that your installer has connected
to input 1 on the main PCB J2 connector (such as a back-up
ALARMNET radio transmitter). Bypassing this zone causes
the system to ignore the status of devices connected to input
1.
zone #974: monitors the supervision status of the main dialer
output (if enabled at installation time). Bypassing this zone
disables the operation and supervision of the main dialer
output.
zone #975: monitors the supervision status of the back-up
dialer output (if installed and enabled at installation time).
Bypassing this zone disables the operation and supervision
of the back-up dialer output.
zone #976: this zone is assigned to the auxiliary relay output.
Actually, this zone does not monitor anything since the
auxiliary relay output is not supervised. However,
bypassing this zone allows the operation of the auxiliary
relay output to be disabled.
zone #977: this zone is assigned to the ALARMNET radio
trigger outputs. Actually, this zone does not monitor anything
since the ALARMNET triggers are not supervised. However,
bypassing this zone allows the operation of the triggers to be
disabled.