Safety READ AND FOLLOW ELECTRICAL SAFETY SAFETY INSTRUCTIONS! Capacitor voltage may be hazardous. To discharge motor capacitor, hold insulated handle screw- This is the safety alert symbol. When you see this driver BY THE HANDLE and short capacitor terminals symbol on your pump or in this manual, look for together.
Table of Contents Thank you for purchasing a top quality, factory tested pump. Page General Safety .....................2 Installation ......................4,5 Connecting Discharge Piping................6 Electrical ......................7,8 Preparing To Start The Pump................9 Troubleshooting....................10 Repair Parts .......................11 Warranty ......................12 Performance Chart GPH at depth to water Model Disch.
Installation REPLACING AN OLD PUMP To Household Pump Priming Water System Tee and Plug Hazardous voltage. Disconnect power to pump before work- ing on pump or motor. Step 1. Drain and remove the old pump. Check the old pipe for scale, lime, rust, etc., and replace it if necessary.
Installation To Household Pump Priming Step 4. Install a priming tee, priming plug, and suction pipe to the pump Water System Tee and Plug (see Figure 2). Connect the pipe from the well to the pump suction port, using the fewest possible fittings – especially elbows – as fit- tings increase friction in the pipe (however, include a foot valve –...
Discharge Pipe and Pressure Tank Connections PRE-CHARGE TANK CONNECTION (Figure 4) To Household Pump Priming Water System Tee and Plug Step 1. Install two tees in the pump discharge port (see Figure 4). The pipe size must be at least as large as the discharge port. Step 2.
Electrical Disconnect power before working on pump, motor, pressure switch, or wiring. Your Motor Terminal Board (under the motor end cover) wiring if line voltage is 230 Volts or if you have a single and Pressure Switch look like one of those shown below. voltage motor.
Page 8
Electrical Connection Procedure: Step 1. Connect the ground wire first as shown in Figure 6. The ground wire must be a solid copper wire at least as large as the power sup- ply wires. Step 2. There must be a solid metal connection between the pressure switch and the motor for motor grounding protection.
Preparing to Start the Pump PRIMING Never run pump against closed discharge. To do so can boil water inside pump, causing hazardous pressure in unit, risk of explosion and possibly scalding persons handling pump. Fill pump Never run pump dry. Running pump without water may cause and piping pump to overheat, damaging seal and possibly causing burns to persons through...
Troubleshooting SYMPTOM POSSIBLE CAUSE(S) CORRECTIVE ACTION Motor will not run Disconnect switch is off Be sure switch is on. Fuse is blown or circuit breaker tripped Replace fuse or reset circuit breaker. Starting switch is defective DISCONNECT POWER; Replace starting switch. Wires at motor are loose, Refer to instructions on wiring (Pages 7 and 8).
Repair Parts Nozzle Cleanout Port 2763 0197 REPAIR PARTS LIST HNC-L HNDX HND-L HNEX HNE-L HNFX Part Description Qty. 1/2 HP 3/4 HP 3/4 HP 1 HP 1 HP 1-1/2 HP Motor A100CHL A100DLL A100DHL A100ELL A100EHL A100FLL Capscrew 3/8-16x1-1/4” Lg. Hex Hd. U30-75ZP U30-75ZP –...
LIMITED WARRANTY Sta-Rite Industries, Inc., warrants to the original consumer of the products listed below, that they will be free from defects in material and workmanship for the Warranty Period from the date of original installation or manufacture as noted.