Download Print this page

Electrolux EFC 9020X Installation And Operating Instructions Manual page 9

Air purification center wall-mounted with cord suspension

Advertisement

At the carbon cartridge again loosen 2 knurled screws and change old carbon against new carbon
Retighten knurled screws loosened before
Insert stainless steel filter (15) into hood body
Stainless steel filter with activated
carbon cartridge (rear side)
9. What to do if ...
Hood crackles:
Some sporadic crackling in the hood is normal. It indicates that air is cleaned by the ionizer. When
crackling continues persistently, the upper metal filters and the ionize sheet must be cleaned.
Furthermore you should check if the connector of the supply cable is connected to the ionizer sheet
horizontally.
In case of undervoltage it can happen in power step 1 that the interconnecting relay for the ionizer and
for the UVC lamp switches on and off several times (flips). You can eliminate this by shortly activating
power step 3.
Hood cannot be switched on:
Check if all filters are inserted correctly, since each filter is provided with a microswitch, which interrupt
the circuit in the hood if any of the filters is not correctly in place.
Carbon cartridge
detachable
Stainless steel
filter
Opening for emptying
loose activated carbon