Arming the System

Auto Stay Feature

If this feature is enabled by installer, the LynxSIA Plus, when armed AWAY from the control's keypad
or a Wireless Keypad, switches to the STAY mode if the Exit Time expires and no exit has been made.
NOTE:
If the exit route entry/exit sensor is in a check condition or has been bypassed it will result in a loss of interior
protection because the alarm system will arm STAY in this case. Consult with your installer for servicing of the
entry exit zones or to turn off this feature if a check condition on entry exit zones occurs.
Arming the System with No Delay
Use NO DELAY with STAY mode when you are staying home and do not expect anyone to use the
entrance door.
Use NO DELAY with AWAY mode when the premises will be vacant for extended periods of time such
as vacations, etc.
When armed with NO DELAY, the keypad beeps twice, or beeps continuously if exit warning has been
programmed for your system, and displays the "Armed Stay Instant" or "Armed Away Instant"
message. The red ARMED indicator lights and the system announces "Armed STAY Instant –exit now"
or "Armed AWAY Instant –exit now".
When armed with NO DELAY, the system will sound an alarm if a protected door or window is opened,
including the entrance door. You may leave through the entrance door during the exit delay period
without causing an alarm, but an alarm will sound as soon as someone reenters.
To arm with NO DELAY:
** See Quick Arming paragraph.

Quick Arming

If Quick Arm was programmed by the installer, you do not need to enter the security code to arm the
system. Instead, simply press and hold down the desired arming key for at least 2 seconds. The
security code must always be used to disarm the system, however.
To arm if Quick Arm is active:
To arm with NO DELAY if Quick Arm is active:
least 2 seconds
IMPORTANT: The Babysitter Code and Installer Code cannot disarm the system unless it was used to
arm the system. In addition, if the system is armed by pressing and holding the Quick-Arm buttons,
neither the Babysitter Code nor Installer Code can disarm the system.
+ AWAY or STAY + NO DELAY
Your user code**
AWAY or STAY hold down for at least 2 seconds
– 18 –
AWAY or STAY
then NO DELAY hold down for at

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lynx Plus Series and is the answer not in the manual?

Questions and answers

Joseph Pires
January 18, 2025

Recently had a sensor moved by the security people. They left everything in the CHIME Mode. I would like to turn that mode off, as it initially was. Is it as simple as pressing the function button and the #9 button? Thanks in advance.......

1 comments:
Mr. Anderson
February 4, 2025

To turn off the CHIME Mode on a Honeywell Lynx Plus Series system, press FUNCTION + CHIME.