Advertisement

Installation, Operating, Maintenance
and After Sales Manual.
SLIM-LINE RC
heatingthroughinnovation.
Product Serial Number:
Please leave this manual with the end user.
Part Number: 1370064
Issue 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLIM-LINE RC and is the answer not in the manual?

Questions and answers

Mr A Kirkham
January 23, 2025

What is the part number for the Dyson Slim Line wall mounted heater

1 comments:
Mr. Anderson
February 10, 2025

The part number for the Myson Slim-Line RC wall mounted heater is 1371057.

This answer is automatically generated

Summary of Contents for Myson SLIM-LINE RC

  • Page 1 Installation, Operating, Maintenance and After Sales Manual. SLIM-LINE RC heatingthroughinnovation. Product Serial Number: Please leave this manual with the end user. Part Number: 1370064 Issue 4...
  • Page 2: Table Of Contents

    Contents General Information Heating System Design Unit Selection/Sizing Location Preparation Fixing Water Connections Electrical Connection Commissioning Procedure 10.0 Technical Data 11.0 Operating Instructions 12.0 Troubleshooting 13.0 Maintenance...
  • Page 3: General Information

    4.0 Location l This SLIM-LINE RC unit may be fitted to any convenient wall l The unit should be mounted on a flat wall, and stud or at a height from floor level that suits the application,...
  • Page 4: Preparation

    SLIM-LINE RC 5.0 Preparation Before proceeding with the installation, unpack the carton contents and check against the checklist below: 1. SLIM-LINE RC unit. 2. 15mm isolating valves (1 pair). 3. Instruction manual. 4. Warranty card. 5. Fixing kit (rubber mounts and cable gland).
  • Page 5: Water Connections

    - see Commissioning Procedure. exchanger. Note: For SLIM-LINE RC installations pipe-work must not be routed directly underneath the unit as this will adversely affect the operation of the integral room thermostat. If this cannot be avoided, the pipe-work must be boxed to prevent heat rise.
  • Page 6: Electrical Connection

    SLIM-LINE RC 8.0 Electrical Connection WARNING: This appliance must be earthed. The electrical installation must comply with local or national wiring regulations. l This unit is supplied with factory fitted test leads. Remove l Connect live and neutral wires to the power board terminal these and discard.
  • Page 7: Commissioning Procedure

    SLIM-LINE RC 9.0 Commissioning Procedure l Fill and vent the system. l Isolate electrical supply. l Open both valves fully and vent air from the heat exchanger l Remove outer cover. by unscrewing the air bleed valve situated above the valves in l Change switch 1 position according to requirements the angled top of the chassis.
  • Page 8: Technical Data

    SLIM-LINE RC 10.0 Technical Data Heating Performance Data Temperature Difference (°C) Power Fan Speed Consumption Heat Output (watts) Heat Output (Btu/h) (watts) 20° 30° 40° 50° 60° 20° 30° 40° 50° 60° Normal 1340 1820 2290 2770 2934 4572 6210...
  • Page 9: Operating Instructions

    32°C. This means This SLIM-LINE RC unit is fitted with a control system that that heating performance can be controlled manually, and the provides 3 different operating modes.
  • Page 10: Troubleshooting

    12.0 Troubleshooting Once installed this fan convector becomes part of a complete Note: If you call out MYSON Service to a fault detailed opposite, heating system that will generally include a boiler, pump, other or to repair a fault caused by incorrect use, a call out charge will emitters such as radiators and fan convectors, and a number of be made.
  • Page 11: Maintenance

    Note: Operation of fan convector can be checked by water sensor switching to manual fan setting If the fan convector is still faulty after checking the above, call your installer or MYSON Service. Common Installation Faults heat, and the heating system must be correctly designed to provide adequate flow of hot water to the unit (refer to section 2).
  • Page 12 Serial Number Location: Inner chassis position heatingthroughinnovation. After Sales Service: MYSON Service, Somerden Road, Hull, East Yorkshire HU9 5PE T: 01482 713927, F: 01482 789056, service.convectors@myson.co.uk Spare parts and technical help on all Convector products are available from MYSON Service.

Table of Contents