Level Diagram - Kenwood 762G Service Manual

Vhf fm transceiver
Table of Contents

Advertisement

Receiver Section
Center Frequency
Transmitter Section
Control Unit
To make measurements in the AF section, connect the AC level meter.
AG is set so that MIC input becomes 3kHz/1.5kHz (Wide/Narrow) DEV at 1kHz MOD.
78
TK-760G/762G

LEVEL DIAGRAM

49.95MHz
To make measurements in the RF section, connect the RF
level meter.
In the RF section, use a 0.01 F coupling capacitor.
(The display shows the SSG input value required to obtain
12dB SINAD.)
TX-RX Unit
VCO Unit
To make measurements in
the RF section, connect the
RF wattmeter (50 ).
TK-760G/762G
450kHz
To make measurements in the AF section, connect the AC level meter.
(ANT input : –53dBm, 1kHz FM, 3kHz DEV (Wide) / 1.5kHz DEV (Narrow))
The AF output level is adjusted for 0.45V/4 by the front panel AF VOL control.
TX-RX Unit
79
Audio Frequency
Power Module
TX-RX Unit