User Manual uEye Cameras V3.32
Capture Errors
Select View menu ® Capture errors on the main menu to display the Capture Errors dialog box.
Figure 74: View menu - Capture errors
Error type
API no destination memory
API conversion failed
API image locked
DRV out of buffers
DRV device not ready
USB transfer failed
DEV timeout
ETH buffer overrun
ETH missed images
84
Description
There is no destination memory for copying the finished
image.
The current image could not be processed correctly.
The destination buffers are locked and could not be
written to.
No free internal image memory is available to the driver.
The image was discarded.
The camera is no longer available. It is not possible to
access images that have already been transferred.
The image was not transferred over the USB bus.
The maximum allowable time for image capturing in the
camera was exceeded.
The sensor transfers more data than the internal camera
memory of the GigE uEye can accommodate.
The GigE uEye camera could neither process nor output
an image captured by the sensor.