Summary of Contents for Fujitsu PRIMERGY SX940

  • Page 1 PRIMERGY SX940 Service Supplement Edition Draft...
  • Page 2: Copyright And Trademarks

    Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2009 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3: Table Of Contents

    Contents Introduction ......5 Overview of the documentation ....5 Notational conventions .
  • Page 4 Contents Appendix ......37 Board layout ......37 6.1.1 4-port controller (LSI 1064) .
  • Page 5: Introduction

    Introduction The PRIMERGY SX940 Server is a storage subsystem for the PRIMERGY BX900 S1 and the follow-up models. Overview of the documentation Concept and target groups This Service Supplement completes the information given in the Operating Manual. The activities described in this manual may only be performed by service personnel.
  • Page 6 – Commisioning Installation/removal of all hot-plug components: – hot-plug hard disk drives Troubleshooting Replacement routines: Service Supplement – Controllerl – iBBU – SC940 complete (with cabling) Board layouts and cabling Table 1: Overview of the documentation PRIMERGY SX940 Review SX940...
  • Page 7: Notational Conventions

    Introduction Notational conventions Notational conventions The following notational conventions are used in this manual: Text in italics indicates commands, menu items or software programs. „Quotation marks“ indicate names of chapters and terms that are being emphasized. Ê describes activities that must be performed in the order shown.
  • Page 9: Procedure

    Procedure CAUTION! The actions described in these instructions should only be performed by service personnel. Ê First of all please familiarize yourself with the safety instructions in the chapter “Safety notes” on page Ê Ensure that all required manuals (see Service DVD) are available, printing out the PDF files if necessary.
  • Page 11: Safety Notes

    Safety notes The following safety notes are also provided in the “Safety notes and other important information” manual. This device complies with the relevant safety regulations for data processing equipment. CAUTION! The actions described in these instructions should only be performed by service personnel.
  • Page 12 Safety notes Modules with electrostatic-sensitive components: Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: ●...
  • Page 13: Replacement Routines

    Replacement routines Preparation Replacement routines In case of an error the following parts can be replaced: – Controller – iBBU – Cables If these parts are not the failure cause the remained parts will be replaced (SX940 complete with cabling). CAUTION! Observe the safety instructions in the chapter “Safety notes”...
  • Page 14: Opening The Storage Blade

    Preparation Replacement routines 4.1.2 Opening the storage blade Figure 2: Opening the storage blade Ê Press down the touch point (1). Ê Push the housing cover in the direction of the arrow as far as it will go (2). Ê Lift off the housing cover. Review SX940...
  • Page 15: Closing The Storage Blade

    Replacement routines Preparation 4.1.3 Closing the storage blade Figure 3: Closing the storage blade Ê Position the server blade cover on the housing approx. 1-2 cm from the frame, so that it is level on both sides. Ê Push the cover in the direction of the arrow until it clicks into place. Review SX940...
  • Page 16: Controller

    Controller Replacement routines Controller The storage blade can be fitted with one or two controllers of the LSI 1064 or LSI 1078 type. The controller(s) support(s) up to four HDD modules. CAUTION! All unused cable ends have to be equipped with protective caps.. Fitting rules In a configuration with only one controller , either the left server blade (controller 1) or the right server blade (controller 2) will be operated.
  • Page 17 Replacement routines Controller In a configuration with two controllers, both the left and right server blades will be operated. You can plug in 2-4 HDDs. The slots for the hard disk drive modules must be filled as follows: Controller 1. HDD 2.
  • Page 18: Replacing Controller

    Controller Replacement routines 4.2.1 Replacing controller The replacing of a controller wil be described exemplary at the following config- uration: – One LSI 1064 controller for two HDDs For the further configurations see chapter “Different configurations” on page 23 Ê Remove the storage blade as described in section “Removing the storage blade”...
  • Page 19: Replacing Ibbu

    Replacement routines Replacing iBBU Replacing iBBU Together with the LSI 1078 controller, an iBBU can be installed. Ê Remove the storage blade as described in section “Removing the storage blade” on page Ê Open the storage blade as described in section “Opening the storage blade”...
  • Page 20 Replacing iBBU Replacement routines Figure 7: Removing the iBBU Ê Remove the iBBU cable from the connector of the controller (1). Ê Take the iBBU out of the device (2). Figure 8: Removing the iBBU cable Ê Remove the iBBU cable from the iBBU (1). Ê...
  • Page 21 Replacement routines Replacing iBBU A sequence of numbers canbe found on the back side the plug. That side of the plug has to be turned down. Ê Check wether the cable of the battery in the new iBBU is connected (2). Figure 9: Installing the iBBU Ê...
  • Page 22: Replacing Sx940 Complete (With Cabling)

    Replacing SX940 complete (with cabling) Replacement routines Replacing SX940 complete (with cabling) If the controller, the iBBU, and the cables will be quite correct you have to change the remain parts. The cabling in the spare part „SX940 complete with cabling“...
  • Page 23: Different Configurations

    Different configurations Because of the two controllers and the two HDD diskbays different configura- tions for installing are possible. They are describes on the following pages. – Configuration: Two HDDs using one LSI 1064 controller, see page 24 – Configuration: Four HDDs using one LSI 1064 controller, see page 25 –...
  • Page 24: Controllerlsi 1064

    ControllerLSI 1064 Different configurations ControllerLSI 1064 5.1.1 Configuration: Two HDDs using one LSI 1064 controller Ê Remove the storage blade as described in section “Removing the storage blade” on page Ê Open the storage blade as described in section “Opening the storage blade” on page Prerequisites No controller installed, HDDs not connected.
  • Page 25: Configuration: Four Hdds Using One Lsi 1064 Controller

    Different configurations ControllerLSI 1064 CAUTION! All unused cable ends have to be equipped with protective caps to avoid short curcuits! Ê Lay the unused cable ends of the two SAS cables at suitable locations. 5.1.2 Configuration: Four HDDs using one LSI 1064 controller Ê...
  • Page 26 ControllerLSI 1064 Different configurations Ê Plug the connector P1 of the SAS cable into the connector on the HDD diskbay 0/1 (3). Ê Plug the connector P2 of the SAS cable into the connector on the HDD diskbay 2/3 (4). Ê...
  • Page 27: Configuration: Four Hdds Using Two Lsi 1064 Controllers

    Different configurations ControllerLSI 1064 5.1.3 Configuration: Four HDDs using two LSI 1064 controllers Ê Remove the storage blade as described in section “Removing the storage blade” on page Ê Open the storage blade as described in section “Opening the storage blade” on page Prerequisites No controller installed, HDDs not connected.
  • Page 28 ControllerLSI 1064 Different configurations Verkabeln des Controllers 2 – Plug the controller into the contact strip of the main board #2 and fix it with a screw (as mounting controller #1). – Plug the connector HOST of the upper SAS cable into the SAS connector (4) on the controller #2.
  • Page 29: Lsi 1078 Controllers

    Different configurations LSI 1078 controllers LSI 1078 controllers 5.2.1 Configuration: Two HDDs using one LSI 1078 controller Ê Remove the storage blade as described in section “Removing the storage blade” on page Ê Open the storage blade as described in section “Opening the storage blade”...
  • Page 30: Configuration: Four Hdds Using One Lsi 1078 Controller

    LSI 1078 controllers Different configurations ACHTUNG! All unused cable ends have to be equipped with protective caps to avoid short curcuits! Ê Lay the unused cable ends of the two SAS cables at suitable locations. 5.2.2 Configuration: Four HDDs using one LSI 1078 controller Ê...
  • Page 31 Different configurations LSI 1078 controllers Ê Plug the connector named P2 of the SAS cable into the connector on the HDD diskbay 2/3 (4). Ê Plug the power cable for the HDD 0/1 from connector J3 on main board #2 onto the connector J4 of main board #1.
  • Page 32: Configuration: Four Hdds Using Two Lsi 1078 Controllers

    LSI 1078 controllers Different configurations 5.2.3 Configuration: Four HDDs using two LSI 1078 controllers Ê Remove the storage blade as described in section “Removing the storage blade” on page Ê Open the storage blade as described in section “Opening the storage blade” on page Prerequisites No controller installed, HDDs not connected.
  • Page 33 Different configurations LSI 1078 controllers Cabling of controller #2 Ê Plug the controller into the contact strip of the main board #2 and fix it with a screw (as mounting controller #1). Ê Plug the connector HOST of the upper SAS cable into the SAS connector MLC1 (4) on the controller #2.
  • Page 34: Mixed Installation

    Mixed installation Different configurations Mixed installation In a mixed installation with different controllers the following controller configu- ration has to be observed: 1. LSI 1078 controller within mounting location for controller #1 (lower location) 2. LSI 1064 controller within mounting location for controller #2 (upper location) Ê...
  • Page 35: Sx940 Review

    Different configurations Mixed installation Ê Plug onto the connector P2 of the lower SAS cable a protective cap and lay the unused cable end at suitable location. Cabling of controller #2 Ê Plug the controller into the contact strip of the main board #2 and fix it with a screw (as mounting controller #1).
  • Page 37: Appendix

    Appendix Board layout 6.1.1 4-port controller (LSI 1064) Part number: A3C40090846 Figure 22: 4-Port-Controller (LSI 1064) Pos. Description SAS connector Review SX940...
  • Page 38: 8-Port Controller (Lsi 1078)

    Board layout Appendix 6.1.2 8-port controller (LSI 1078) TPart number: A3C40090845 Figure 23: 8-Port-Controller (LSI 1078) Pos. Description RAID key iBBU connector SAS connector MLC1 SAS connector MLC2 ??? Review SX940...
  • Page 39: Ibbu

    Appendix Board layout 6.1.3 iBBU Part number: A3C40097073 Figure 24: iBBU Pos. Description iBBU (battery) with electronic parts underneath 3 screws to fix the iBBU to the bottom plate of the blade Cable connecting iBBU to controller Review SX940...
  • Page 40: Sx940 Complete (With Cabling)

    Board layout Appendix 6.1.4 SX940 complete (with cabling) Part number: A3C40112020 Figure 25: SX940 compete (with cabling) Pos. Bezeichnung Main board 1 Main board 2 Connector J4 Connector J3 Diskbay 0/1 Diskbay 2/3 Review SX940...
  • Page 41: Cables

    Appendix Cables Cables 6.2.1 SAS cable Part number: A3C40104636 Figure 26: SAS-Kabel Pos. Bezeichnung HOST, plug for the connector on the controller P1, plug for the connector on the HDD diskbay P2, plug for the connector on the HDD diskbay Review SX940...
  • Page 42: Further Cables

    Cables Appendix 6.2.2 Further cables Further cables, available as spare parts: Pos. Teilenummer Bezeichnung A3C40092034 iBBU cable A3C40104638 LED cable A3C40104637 Power cable Review SX940...
  • Page 43: Index

    Index cable main board 1 17, iBBU main board 2 17, meaning of the symbols Power mixed installation configuration cable ends 16, 25, MLC1 connector J3 MLC2 connector J4 controller notational conventions LSI 1064 LSI 1078 controller 1 overview documentation controller 2 diskbay 0/1 diskbay 2/3...