Environment
6.2
6.2.1
Temperature and humidity
Operating conditions
Temperature
Relative humidity
Maximum wet bulb temperature
Maximum temperature gradient
Altitude
Non-Op conditions
Temperature
Relative humidity
Maximum wet bulb temperature
Maximum temperature gradient
Altitude
Table 12 Temperature and humidity
Notes:
1. The system is responsible for providing sufficient ventilation to maintain a surface temperature below
65°C at the center of the top cover of the drive.
2. Non condensing conditions should be maintained at any time.
3. Maximum storage period within shipping package is one year,
0 to 60°C
8 to 90% non-condensing
29.4°C non-condensing
20°C/Hour
–300 to 3,048 m
-40 to 70°C
5 to 95% non-condensing
35°C non-condensing
30°C/Hour
–300 to 12,000 m
Hitachi hard disk drive specifications