Table 5-3. POST Error Codes and Messages (continued)
Error Code and Message
0C00
Rompilot reports error number
xx
Expansion ROM not initialized
Invalid System Configuration Data
NOTICE:
Your System Redundant Power Supply is not
configured
Resource Conflict
System Configuration Data Read error
System Configuration Data Write error
Warning: IRQ not configured
5-28 Problem Solving
Description
Configuration error in
SETUP.
CPU/PCI module board is
faulty.
Configuration error in Setup
menu.
Configuration error in
Setup menu.
CPU/PCI module board is
faulty.
SMBus device is faulty.
SMBus is faulty.
Configuration error in Setup
menu.
Configuration error in
Setup menu.
CPU/PCI module board is
faulty.
Configuration error in Setup
menu.
Action
Re-configure Rompilot.
Replace the CPU/PCI module
board.
Disable the ROM Expansion
for unnecessary options.
Specify "Yes" for Reset
Configuration Data to clear the
configuration.
Replace the CPU/PCI module
board.
Check cable connection.
Replace the cable.
Replace the CPU/PCI module
board.
Re-configure the device
configuration using SETUP.
Specify "Yes" for Reset
Configuration Data to clear the
configuration.
Replace the CPU/PCI module
board.
Reconfigure using SETUP.