Scopia Xt1000 - Samsung VC240 Reference Manual

Reference guide
Hide thumbs Also See for VC240:
Table of Contents

Advertisement

SCOPIA XT1000

Table 1-19
Table 1-19
Ports Supported by SCOPIA XT1000 Series
Port number
Protocol/
Use
69
TFTP (UDP)
80
HTTP (TCP)
123
SNTP (UDP)
161
SNMP (UDP)
162
SNMP(UDP)
1718
H.225.0/
RAS (UDP)
1719
H.225.0/
RAS (UDP)
1720
H.225.0/
Q.931 (TCP)
3230-3248
H.225.0/
Q.931 and
(configurable)
H.245 and SIP
(TCP)
RADVISION | RADVISION Port Security Reference Guide
lists ports that need to be open on SCOPIA XT1000.
Functionality Direction
TFTP client or
Both
server
Web server
Both
SNTP client
Both
SNTP
Both
Configuration
and Status
SNTP Trap
Out
Events
H.323 call
Out to the
signaling to a
multicast
GK for
IP address
"Gatekeeper
224.0.0.41
Automatic
(all GK)
Discovery"
procedure
H.323 call
Both
signaling to a
GK
H.323 call
Both
signaling
(Q.931)
For H.323 call
Both
control
signaling
(Q.931),
media control
signaling
(H.245), SIP
(TCP) call
signaling, and
BFCP signaling
Result of Blocking Port on
Firewall
Cannot send or receive files
via TFTP
In: No web server.
Out: Also NAT
auto-discovery using HTTP
does not function.
Cannot get the Internet UTC
time
Cannot configure or check
the status of the terminal via
SNMP
The terminal cannot send
SNMP events
The H.323 endpoint cannot
automatically discover a
gatekeeper (only manual
configuration available).
The H.323 endpoint cannot
use the services of a
gatekeeper.
Cannot connect H.323 calls. Common H.323 service
Cannot connect H.323 calls.
Cannot connect SIP calls on
TCP transport.
Description/External
Client
Send or receive files via
TFTP
WEB remote management
or use, NAT autodiscovery
using HTTP .
Get the Internet UTC time
Interface to iVIEW Network
Manager or any other SNMP
manager station
Interface to iVIEW Network
Manager or any other SNMP
manager station
The H.323 endpoint can
automatically discover a
gatekeeper.
The H.323 endpoint uses
the services of a
gatekeeper
port.
Ephemeral TCP ports used
to connect simultaneous
H.323 and SIP calls.
The range can be modified
by selecting Administrator
Settings > Network >
Preferences >Dynamic
Ports
| 28

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scopia series

Table of Contents