Installing the Redundant Power Supplies

Install the two redundant power supplies in the server as follows:
Perform the following procedures for each power supply.
1. Attach the two power supply cables to the connector bracket on the back of
the power supply carrier supplied with your kit (see the following figure).
2. Secure the power supply to the carrier with four screws on the rear carrier
plate and two screws on the front supporting brackets of the power supply
(see the following figure).
3. Slide the power supply carrier into the power supply slot and secure with the
three thumbscrews.
Attaching the Two Power Supply Cables
Attaching the Power Supply to the Carrier
Redundant Power Upgrade Kit Installation Procedures 17