2.9.3 Pitched roof installation

4
8
Fig. 2.49 Fitting the appliance and the vertical roof duct to a
building with a pitched roof
Key
* = 190 mm ecoTEC exclusive combination
* = 176 mm ecoTEC plus open vent
* = 125 mm ecoTEC plus system & combination
* = 323 mm ecoTEC plus 937
** = 750 mm ecoTEC exclusive combination
** = 530 mm ecoTEC plus open vent (top holes of
bracket)
** = 622 mm ecoTEC plus system & combination
** = 622 mm ecoTEC plus 937
• Determine the point where the vertical air/flue duct
and terminal assembly will penetrate the roof.
• Fit the flexible pitched roof (Accy. No. 303 980) tile (1,
Accy. No. 303 980).
• Working from above, insert the vertical roof duct (5)
through the roof tile and push it firmly into place.
• Vertically align the roof duct and attach it to the roof
structure with the fixing bracket (6) supplied.
• Fit the boiler hanging bracket (2).
• Install the appliance (3) with reference to the installa-
tion and servicing instructions supplied with the boil-
er.
Flue installation instructions ecoTEC 834449_13
Standard Concentric Systems Ø 60/100 2
5
1
6
Ø 100
7
8
2
3
Note
h
See section 2.11 for further details on the in-
stallation of extensions and elbows.
• Push the sliding sleeve (4) firmly into place on the ex-
tension.
• Join the vertical roof duct (5) to the extension (7).
• Join the sliding sleeve (4) to the appliance's connec-
tion piece (8).
Note
h
Using the sliding sleeve allows the appliance to
be easily removed and replaced without dis-
mantling the flue.
• Drill two holes 3 mm Ø through the air duct of the
flue/boiler clamp at the most convienient holes on the
air duct clamp. (Ensure that the drill does not pene-
trate the inner flue duct). Screw the clamp to the air
ducts of the flue assembly and the boiler using the
screws supplied.
• Ensure that any air duct clamps used are positioned
centrally and fixed to the air duct using the self tap-
ping screws supplied.
h
Note
The air/duct clamp must not be screwed to the
bottom of the vertical air/flue duct and termi-
nal accessory to allow for any slight movement
in the roof structure.
• Ensure that at least one pipe clamp supports the air/
flue duct at each extension fitted.
27