Model Number: GM678
Tested by: Hank Huang
Test Mode: Mode 1
Test Results: Passed
Temperature: 20°C
(The chart below shows the highest readings taken from the final data)
FREQ
Q.P.
M H z
RAW
dBuV
0.150
40.10
1.650
25.40
3.470
27.10
16.080
28.90
18.650
29.10
19.330
28.60
0.150
41.50
0.910
27.20
3.750
24.30
4.150
25.60
15.840
27.30
17.680
30.70
L1 = Line One (Hot side) / L2 = Line Two (Neutral side)
**NOTE: "---" denotes the emission level was or more than 2dB below the Average limit,
so no re-check anymore.
6 SUMMARY DATA
(LINE CONDUCTED TEST)
AVG
Q.P.
RAW
Limit
dBuV
dBuV
---
66.00
---
56.00
---
56.00
---
60.00
---
60.00
---
60.00
---
66.00
---
56.00
---
56.00
---
56.00
---
60.00
---
60.00
Report Number: 030355-D
April 29, 2003
Location: Site # 4
Humidity: 65%RH
AVG
Q.P.
Limit
M argin
dBuV
dB
56.00
-25.90
46.00
-30.60
46.00
-28.90
50.00
-31.10
50.00
-30.90
50.00
-31.40
56.00
-24.50
46.00
-28.80
46.00
-31.70
46.00
-30.40
50.00
-32.70
50.00
-29.30
AVG
NO TE
M argin
dB
---
L1
---
L1
---
L1
---
L1
---
L1
---
L1
---
L2
---
L2
---
L2
---
L2
---
L2
---
L2