Installation; Location; Climate Range; Ventilation - Miele GT 316 ES Operating Instructions Manual

Chest freezer with "stop frost" system
Table of Contents

Advertisement

Installation

Location

The appliance should be installed on a
level and stable surface.
Do not install the appliance up against
other appliances or units. There must
be a minimum distance of 20 mm all
around the appliance to ensure
sufficient ventilation.
It should be situated far enough away
from a wall to ensure that the lid can be
opened and closed easily.
The appliance should be installed in a
dry, well-ventilated room.
The room temperature should not go
above or below the climate range for
which the appliance is designed.
The higher the ambient temperature of
the room, the more energy the
appliance requires to operate.
It should not be installed where it is
exposed to direct sunlight or directly
adjacent to a heat-producing appliance
such as an oven or a radiator.
34

Climate range

The appliance is designed for use
within certain climate ranges (ambient
temperatures), and should not be used
outside this range. The climate range of
this appliance is stated on the data
plate on the outside the appliance.
Climate range
SN, N
ST
T
The appliance will function perfectly
down to an ambient temperature of
+5 °C.

Ventilation

In order to ensure sufficient ventilation
– the gap between the bottom edge of
the freezer and the floor on which it
is standing must not be covered.
– there must be a minimum distance of
20 cm from the ventilation gap to the
wall to ensure that ventilation to and
from the appliance is unhindered.
– the ventilation gap should be dusted
on a regular basis.
Ambient room
temperature
up to +32 °C
up to +38 °C
up to +43 °C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents