Chapter 5 Troubleshooting
No. Class
Status
41.
42.
Table 5.1.1 Problem descriptions and recommended actions(IP-900D/IP-900IID)
No. Class
Status
1
Power cannot
be turned on.
2
The ALM LED
3
is blinking.
The ALM LED
4
is on.
The LEDs
excluding LAN
5
are on.
6
Data
7
communication
is disabled.
8
IP-900E/IP-900D series
Description
Are the network settings (IP
address, subnet mask, etc.) on the
control terminal PC correct?
Is a reply received in response to a
PING command issued to the IP
address of the device?
Description
Is the power cable connected?
Is the outlet voltage normal?
Check the log information from the
browser.
The temperature inside the device
has risen to the critical level, the fan
speed has fallen, or a CF card
access error has occurred.
The device is faulty.
Is the ambient temperature of the
device higher than that in the
specifications?
Is there any shielding material in
the installation space?
Is the port setting correct?
Is the data input/output device
operating normally?
Are the device and the
communication destination device
correctly connected?
Make correct settings by referring to the PC
user's guide and OS handbook. If this device is
started with the default settings made before
shipment from the factory, see "Section 3.3.1,
"Settings," for the network settings for the
control terminal PC.
If a reply is not received, turn on the power to
the device while holding down the MNT button
to start the system with the default IP address
(10.0.0.1) set before shipment from the factory.
Confirm the IP address. If the problem
persists, check the status on the LAN. For
information on this startup procedure, see
Section 3.6, "Special Use of Cancel Key."
Make sure that the power cable is properly
connected to the outlet.
Measure the voltage with a tester to confirm that
the voltage is normal.
If another device is connected to the same
outlet, check the operation of the device.
If the ambient temperature of the device is too
high, make proper arrangements to lower the
ambient temperature. If there is any shielding
material in the installation space, remove it.
If the fan speed is low, the fan needs to be
replaced. Contact a Fujitsu Service Center.
In the case of a CF card access error, restart the
device. If the problem persists, contact a
Fujitsu Service Center. The CF card or the
device needs to be replaced.
Troubleshoot from the control terminal.
(For details, see the software manuals.)
Adjust the temperature so that the ambient
temperature of the device meets the
specification's condition.
Remove the shielding material.
Check the data input-output port setting.
Check the operation of the data input/ output
device.
Check cable connections between the device
and communication destination device and the
cable pin assignments.