Download Print this page

Pioneer PDP-614MX External Control Manual

Rs-232c configuration
Hide thumbs Also See for PDP-614MX:

Advertisement

Quick Links

External Control Manual
RS-232C Configuration
(for PDP-614MX and PDP-424MV)
Version 1.0
Dec 2005

Advertisement

loading

Summary of Contents for Pioneer PDP-614MX

  • Page 1 External Control Manual RS-232C Configuration (for PDP-614MX and PDP-424MV) Version 1.0 Dec 2005...
  • Page 2 PDP-614MX External Control Manual Application These specifications are applicable to plasma monitors and communications control from external equipment. Connections Connections should be made as described below. External equipment plasma monitor e.g., Personal computer 1) Connector on the plasma monitor side: EXTERNAL CONTROL connector.
  • Page 3: Communication Parameters

    PDP-614MX External Control Manual 2) Connector on the external equipment side: Serial port (RS-232C) connector. See the specifications of the equipment that is to be connected for the type of connector and the pin assignment. 3) Wiring Use a crossed (reverse) cable.
  • Page 4: Communication Format

    PDP-614MX External Control Manual Communication Format 8bit 8bit 8bit 8bit 8bit 8bit 8bit 8bit Command 1 Unit ID 1 Unit ID 2 Command 2 Data length Data Check sum Command1 Command 1, along with command 2, is a number used to distinguish each command.
  • Page 5 PDP-614MX External Control Manual the lower order 8 bits of one frame of sent or received data comprising the sum total of Command 1, Unit ID 1 and 2, Command 2, Data Length, and Data. Check Sum Example Command1 Unit ID1...
  • Page 6 PDP-614MX External Control Manual The control method of the set by Set ID When controlling two or more sets of plasma monitors, if the command using Set ID is used, it will become controllable individually. The example of the POWER ON command to the plasma monitor which set ID as "5" is shown below.
  • Page 7: Command Reference List

    PDP-614MX External Control Manual Command Reference List CMD1 CMD2 Power ON Power OFF Input Switch Change VOLUME Gain Data AUDIO Mute ON AUDIO Mute OFF CONTRAST Gain Data BRIGHT Gain Data SHARPNESS Gain Data Color Gain Data TINT Gain Data...
  • Page 8 PDP-614MX External Control Manual OSM Select INVESE Set TIMER SWITCH TIMER PROGRAM SETTING PRESENT TIME SETTING MULTI MODE Select MULTI MODE Request AUTO ID SET START PLE LINK VIDEO WALL SETTING POWER DELAY ON (DIVIDER setting : 1/4/9) POWER DELAY ON...
  • Page 9 PDP-614MX External Control Manual 01. Power ON Function The external control equipment switches on the power of the plasma monitor. Transmission Data 9FH 80H 60H 4EH 00H CKS The plasma monitor returns the following ACK when the power is switched on.
  • Page 10 PDP-614MX External Control Manual 03. Input Switch Change Function The external control equipment switches the input of the plasma monitor. Transmission Data DFH 80H 60H 47H 01H DATA00 DATA00 : Input Select 01H : Video1 02H : Video2 03H : Video3...
  • Page 11 PDP-614MX External Control Manual 04. VOLUME Gain Data Function The external control equipment changes the VOLUME gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00: USER SOUND Gain Flag 05H DATA01: VOLUME Gain Flag...
  • Page 12 PDP-614MX External Control Manual 07. CONTRAST Gain Data Function The external control equipment changes the CONTRAST gain data of the plasma c Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : CONTRAST Gain Flag...
  • Page 13 PDP-614MX External Control Manual 01H : +01 10H : +16 Only when a RGB signal is connected DATA02 : SHARPNESS Gain 01H : 1 02H : 2 03H : 3 04H : 4 7FH 60H 80H 7FH 02H DATA00 DATA01...
  • Page 14 PDP-614MX External Control Manual 10. COLOR Gain Data Function The external control equipment changes the COLOR gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : COLOR Gain Flag...
  • Page 15 PDP-614MX External Control Manual 7FH 60H 80H 0AH 01H DATA00 CKS DATA00: 01H : STD 02H : MOVIE1 03H : MOVIE2 04H : Default 05H : Dynamic 13. COLOR TEMP SELECT Function The external control equipment changes the COLOR TEMP of the plasma monitor.
  • Page 16 PDP-614MX External Control Manual 15. GREEN Gain Data Function The external control equipment changes the GREEN Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag DATA01 : GREEN Gain Flag...
  • Page 17 PDP-614MX External Control Manual 16. BLUE Gain Data Function The external control equipment changes the BLUE Gain Data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 04H DATA00 to DATA03 CKS DATA00 : USER PICTURE Gain Flag DATA01 : BLUE Gain Flag...
  • Page 18 PDP-614MX External Control Manual 17. DNR MODE Set Function The external control equipment sets the NR (Noise Reduction) mode of the plasma monitor. Transmission Data DFH 80H 60H C0H 01H DATA00 DATA00: 01H : OFF 02H : LOW 03H : MID...
  • Page 19 PDP-614MX External Control Manual 19. TREBLE Gain Data Function The external control equipment changes the TREBLE gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : TREBLE Gain Flag...
  • Page 20 PDP-614MX External Control Manual 0AH : 2.35:1 7FH 60H 80H 51H 01H DATA00 DATA00 02H : WIDE 03H : ZOOM 04H : STD 05H : FULL 06H : DOT BY DOT 08H : UNDERSCAN 09H : 14:9 0AH : 2.35:1...
  • Page 21 PDP-614MX External Control Manual 22. V.POSITION Gain Data Function The external control equipment changes the V. POSITION gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : V.POSITION Gain Flag DATA02 : V.POSITION Gain...
  • Page 22 PDP-614MX External Control Manual 23. H.POSITION Gain Data Function The external control equipment changes the H. POSITION gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS DATA00 : USER PICTURE Gain Flag DATA01 : H.POSITION Gain Flag...
  • Page 23 PDP-614MX External Control Manual 25. H.SIZE Gain Data Function The external control equipment changes the H.SIZE gain data of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : H.SIZE Gain Flag DATA02 : H.SIZE Gain...
  • Page 24 PDP-614MX External Control Manual 27. PHASE Gain Data Function The external control equipment changes the PHASE gain data (Phase) of the plasma monitor. Transmission Data DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 DATA00 : USER PICTURE Gain Flag DATA01 : PHASE Gain Flag...
  • Page 25 PDP-614MX External Control Manual 29. OSM ADJ. POSITION Data Function The external control equipment sets the position of the OSM menu of the plasma monitor. Transmission Data DFH 80H 60H 1AH 02H DATA00 DATA01 CKS DATA00 : OSM ADJ. Gain Flag...
  • Page 26 PDP-614MX External Control Manual Function The external control equipment switches on or off the PURECINEMA of the plasma monitor. Transmission Data DFH 80H 60H C1H 01H DATA00 DATA00 : PURECINEMA Set 01H : ON 02H : OFF 7FH 60H 80H C1H 01H DATA00...
  • Page 27 PDP-614MX External Control Manual 33. LONG LIFE Set Function The external control equipment sets the PLE, ORBITER, and INVERSE (inverse of image brightness) or WHITE of the plasma monitor. Transmission Data DFH 80H 60H 6BH 03H DATA00 DATA01 DATA02 CKS...
  • Page 28 PDP-614MX External Control Manual 34. SCREEN WIPER Set 2001.7.10 Function INVERSE The external control equipment sets the SCREEN WIPER of the plasma monitor. Transmission Data コマンド追加 DFH 80H 60H C8H 04H DATA00 to DATA03 CKS DATA00 : SCREEN WIPER 00H : No operation...
  • Page 29 PDP-614MX External Control Manual 36. Audio Select Set Function The external control equipment sets combinations of audio and video inputs for the plasma monitor. Transmission Data DFH 80H 60H 70H 02H DATA00 DATA01 CKS DATA00 : AUDIO INPUT 01H : AUDIO1...
  • Page 30 PDP-614MX External Control Manual 37. BNC INPUT Function The external control equipment sets the BNC SELECT of the plasma monitor. Transmission Data DFH 80H 60H 8CH 01H DATA00 CKS DATA00 : BNC SELECT 01H : RGB 02H : Component The plasma monitor returns the following ACK when setting the BNC SELECT:...
  • Page 31 PDP-614MX External Control Manual 40. LANGUAGE Select Function The external control equipment sets the LANGUAGE SELECT of the plasma monitor. Transmission Data DFH 80H 60H 5BH 01H DATA00 DATA00: 01H : ENGLISH 02H : GERMAN 03H : FRENCH 04H : SPANISH...
  • Page 32 PDP-614MX External Control Manual 42. FREQUENCY Request(SIGNAL INFORMATION) Function The external control equipment inquires the Horizontal frequency, Vertical frequency, Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution of the plasma monitor. Transmission Data 1FH 80H 60H 26H 00H CKS...
  • Page 33 PDP-614MX External Control Manual MODE DATA06 No signal - 01H to 80H RGB signal Identification number of PC mode 3.58NTSC Video signal 4.43NTSC PAL-M PAL-N PAL60 SECAM B/W60 B/W50 HD/DVD/DTV signal 480I 480P 576I 576P 720P 1035I 1080I RESOLUTION DATA07: Dots (Low-order byte) 00H: 0 (No signal: 00H)
  • Page 34 PDP-614MX External Control Manual 43. Input MODE Request Function The display returns the current input information by the external control equipment’ s request. Transmission Data 1FH 80H 60H 41H 00H CKS 7FH 60H 80H 41H 01H DATA00 DATA00 : Input Select...
  • Page 35 PDP-614MX External Control Manual DATA04: TINT Gain E0H : -32 * TINT Gain is from -22 (EAH) to FFH : -01 +22 (16H) only during video. 00H : 0 01H : +01 20H : +32 DATA05: SHARPNESS Gain F0H : -16...
  • Page 36 PDP-614MX External Control Manual 01H : +01 1EH : +30 DATA0B: COLOR TEMP SELECT 00H: low 01H: middle 02H: high 03H: middle low 45. Audio Select Request Function The external control equipment inquires the current combinations of audio and video inputs for the plasma monitor.
  • Page 37 PDP-614MX External Control Manual 46. Failure Mode Request Function The external control equipment inquires the detection of failures of the plasma monitor. Transmission Data 1FH 80H 60H 3FH 00H CKS The plasma monitor returns the following ACK: 7FH 60H 80H 3FH 02H DATA00...
  • Page 38 PDP-614MX External Control Manual 47. MODEL NAME Request Function The external control equipment inquires the product code of the plasma monitor. Transmission Data 1FH 80H 60H 17H 00H CKS The plasma monitor returns the following ACK: 7FH 60H 80H 17H 0CH DATA00 to DATA11 CKS...
  • Page 39 PDP-614MX External Control Manual 48.LOW TONE Function The external control equipment sets the dithering processing or error diffusion processing of the plasma monitor. Transmission Data DFH 80H 60H 0CH 01H DATA00 CKS DATA00: 00H:AUTO 01H: dithering processing(for motion picture) 02H: dithering processing (for still picture)
  • Page 40 PDP-614MX External Control Manual 49. C.DETAIL ADJ Function External control equipment can adjust RGB each color which a plasma monitor wants to emphasize. Transmission Data DFH 80H 60H 0DH 07H DATA00 to DATA06 CKS DATA00:RED 00H : -32 20H : 0...
  • Page 41 PDP-614MX External Control Manual 7FH 60H 80H 13H 01H DATA00 CKS DATA00: GAMMA FLAG 01H : Gamma change...
  • Page 42 PDP-614MX External Control Manual 51.Running Sense Function External control apparatus grasps the power supply state of a plasma monitor. A plasma monitor is made to recognize connection of PC CONTROL. Transmission Data 1FH 80H 60H 88H 00H CKS 7FH 60H 80H 88H 01H DATA CKS...
  • Page 43 PDP-614MX External Control Manual 52. OSM OBITER Function In order to decrease printing of a screen by OSM display, whenever it displays OSM, shift operation of the OSM is carried out. Transmission Data DFH 80H 60H 5FH 01H DATA00 DATA00...
  • Page 44 PDP-614MX External Control Manual 54. SERIAL No. Request Function the serial number of the set recorded by EEPROM of a plasma display. External control apparatus read Transmission Data 1FH 80H 60H 15H 00H CKS 7FH 60H 80H 15H 0CH DATA00 to DATA11 CKS Even DATA00-DATA11 is set up as follows.
  • Page 45 PDP-614MX External Control Manual 56.SOFT FOCUS Function External control apparatus sets up the Soft Focus of a plasma monitor. Transmission Data DFH 80H 60H 65H 01H DATA00 CKS DATA00 01H : OFF 02H : LEVEL1 03H : LEVEL2 04H : LEVEL3...
  • Page 46 PDP-614MX External Control Manual 58.BLACK LEVEL SELECT Function External control apparatus sets up the black level (digital signal level) of a plasma monitor. Transmission Data DFH 80H 60H 8FH 01H DATA00 CKS DATA00 01H : LOW 02H : HIGH 7FH 60H 80H 8FH 01H DATA00 CKS...
  • Page 47 PDP-614MX External Control Manual Remote control operation Personal computer control operation 61. INVERSE Set 2001.7.10 Function INVERSE The external control equipment sets the INVERSE (inverse of image brightness) and the WHITE of the plasma monitor. Transmission Data コマンド追加 DFH 80H 60H C7H 03H DATA00 DATA01 DATA02 CKS...
  • Page 48 PDP-614MX External Control Manual 62. TIMER SWITCH Function The external control equipment sets the timer reservation of the plasma monitor. Transmission Data DFH 80H 60H 02H 01H DATA00 CKS DATA00: 00H : Reservation OFF 01H : Reservation ON 7FH 60H 80H 02H 01H DATA00 CKS...
  • Page 49 PDP-614MX External Control Manual DATA06 INPUT : Video1 : Video2 : Video3 : COMPNT1 : COMPNT2 : PC1DSUB : PC2-BNC : PC3-DVI : - (with No Setup) DATA07 MODE : OBIT : INV : WT : WIPER FFH : - (with No Setup) 7FH 60H 80H 30H 00H CKS 64.
  • Page 50 PDP-614MX External Control Manual DATA01 (POSITION OF DIVIDE) 01H : Upper left selected (4 screens) 02H : Upper right selected (4 screens) 03H : Lower right selected (4 screens) 04H : Lower left selected (4 screens) 07H : Top left selected (9 screens)
  • Page 51 PDP-614MX External Control Manual 05H : Multi mode 16 screens 06H : Multi mode 25 screens DATA01 (POSITION OF DIVIDE) 01H : Upper left selected (4 screens) 02H : Upper right selected (4 screens) 03H : Lower right selected (4 screens)
  • Page 52 PDP-614MX External Control Manual Transmission Data 1FH 80H 60H 3BH 00H CKS 7FH 80H 60H 3BH 02H DATA00 DATA01 DATA02 CKS DATA00 (SCREEN DIVIDER SETTING) 01H : Single mode 02H : Multi mode 1 screens 03H : Multi mode 4 screens...
  • Page 53 PDP-614MX External Control Manual DATA02 (DISP MODE) 00H : SPLIT 01H : BRANKING...
  • Page 54 PDP-614MX External Control Manual 67. AUTO ID SET START Function External control apparatus sets up ID automatically to two or more plasma monitors. Transmission Data 5FH 80H 60H F0H 01H DATA00 CKS DATA00 00H~FFH: ID of a master is set up.
  • Page 55 PDP-614MX External Control Manual...
  • Page 56 PDP-614MX External Control Manual 70. POWER DELAY ON(at 4 or 9 multiscreen) Function External control apparatus attaches a time lag to two or more plasma monitors, and turns on a power supply. Transmission Data DFH 80H 60H F2H 01H DATA00 CKS...
  • Page 57 PDP-614MX External Control Manual 72. ORBITER SET Function A picture shift function is set up. Transmission Data DFH 80H 60H 1EH 04H DATA00 to DATA03 CKS DATA00: Mode 00H : OFF 01H : Auto 1 02H : Auto 2 03H : Manual...
  • Page 58 PDP-614MX External Control Manual Transmission Data DFH 80H 60H 2AH 01H DATA00 DATA00 01H : ON 02H : OFF 7FH 60H 80H 2AH 01H DATA00 DATA00 01H : ON 02H : OFF 75. OPTION Select Function Power-on mode, a control lock, and IR remote are set up.
  • Page 59 PDP-614MX External Control Manual 0CH : PC3-DVI DATA03 WORK TIME 01 H-FFH:1 - 255 minutes (1 minute - 4 hours and 15 minutes) DATA04 PROGRAM 1 01H :DIVIDER 1 02H :DIVIDER 4 03H :DIVIDER 9 DATA05 SOURCE 01H :Video1 02H :Video2...
  • Page 60 External Control Manual RS-232C Configuration (for PDP-614MX and PDP-424MV) Pioneer Electronics (USA) Inc. Industrial Solutions Business Group 2265 East 220 Street Long Beach, CA 90810 www.pioneerelectronics.com www.pioneerindustrialav.com...

This manual is also suitable for:

Pdp-424mv