Installing a DSX Analog Door Box and 2PGDAD Module

Connecting PGDAD Door Boxes and Relays

To connect a Door Box:
1.
Find a suitable location for the DSX Analog Door Box.
- The door box is a weather-tight unit and can be installed outdoors.
Run one-pair 24 AWG station cable from the door box to the 2PGDAD Module.
2.
At the door box, strip each conductor about 3/8", connect as shown, then mount the door box.
3.
4.
At the 2PGDAD Module, strip each conductor about 1/4" and connect to the block as shown.
- To make a connection, use a small flat-blade screwdriver to push down on tab, insert the wire, then
5.
Be sure all module jumpers are in the open position.
To connect a relay:
1.
Run one-pair 24 AWG station cable from the relay location to the 2PGDAD Module.
2.
At the relay, connect the station cable following the instructions provided with the relay.
3.
At the 2PGDAD Module, strip the wires about 1/4" and connect to the block as shown.
- To make a connection, use a small flat-blade screwdriver to push down on tab, insert the wire, then
4.
Be sure the relay you choose is compatible with the 2PGDAD Module relay contact specifications.
2PGDAD Module Relay
Contact Specifications
Configuration:
Normally open
Maximum Contact
250 mA @ 120 VAC
Ratings:
500 mA @ 24 VDC
52 ◆ Optional Equipment
release the tab.
release the tab.
To Door 1 Relay
To Door 2 Relay
Figure 32: Connecting PGDAD Door Boxes and Relays
All Jumpers
Open
To Door 2 Door Box
To Door 1 Door Box
DSX-40 Hardware Manual