Download Print this page

Notes - Craftsman 580.675610 Operator's Manual

Ac generator 5600 watt
Hide thumbs Also See for 580.675610:

Advertisement

Available languages

Available languages

StatStatien
TM
The StatStation
TM
displays the nominal load on generator
based on output frequency. It also has a built in maintenance
reminder.
WattageMonitor
The LEDdisplay will indicate 0-95% nominal load.The display
will flash at 90% nominal load and above. If above 95%
nominal load the display will flash "OL" (meaning 'overload').
When load returns to within normal range, the display will
automatically resume nominal load indication. Seethe table
below for operation functions.
MaintenanceReminder
The LEDwill display certain codes to alert you to check oil,
change oil, check or replaceair filter and check or replace
spark plug. The following codes will display:
"C1"
"C2"
"C3"
"C4"
FrequencyRange
62.5-62.0
61.9-61.5
61.4-61.0
60.9-60.5
60.4-60.0
59.9-59.5
59.4-59.O
58.9-58.5
58.4-58.0
57.9-57.5
57.4-57.0
57.0 and below
Check oil at 8 hour increments
Changeoil at 50 hour increments
LEODisplay
0
0
10
20
40
60
70
80
Flash 90
Flash 95
Flash OL
Flash OL
Check or replaceair filter at 25 hour increments
Check or replacespark plug at 100 hour increments
Pushing "Reset" will set the indicated code timer to zero.
If nominal load and maintenancecodes appear
simultaneously, the LEDshall display, alternately, the
nominal load and code as follows:
The code will display for 3 seconds, then 1/2 second off. The
load will display for 6 seconds and then 1/2 second off.
ENGINEMAIHTENANCE
f'_J
Unintentional sparking can result in fire or
electric shock.
WHEN ADJUSTING ORMAKING REPAIRS TOYOUR
GENERATOR
o Disconnect t hespark plugwirefrom the sparkplug andplace
thewire whereit cannotcontactsparkplug.
WREN TESTING FOR ENGINE SPARK
o Useapproved spark plugtester.
o DONOT checkfor sparkwith sparkplug removed.
Oil
Oil Recommendations
NOTE:Use a high quality detergent oil classified "For Service
SF, SG, SH, SJ" or higher. DO NOT use special additives.
1.
Choosea viscosity according to the table below:
104 F_
86
68
50
32
14
4
-22
40 C
30
20
i
o
-10
-20
-30
NOTE:Synthetic oil meeting ILSAC GF-2,API certification
mark and API service symbol with "SJ/CF ENERGY
CONSERVING" o r higher, is an acceptableoil at all
temperatures. Use of synthetic oil does not alter required oil
change intervals.
SAE30: 40°F and higher (5°6 and higher) is good for all
purpose use above 40°F, use below 40°F will cause hard
starting.
10W-30:0 to IO0°F (-18 to 38°C) is better for varying
temperature conditions. This viscosity improves cold weather
starting, but may increase oil consumption above 80°F
(27°C).
*Check oil level frequently at higher temperatures.
Synthetic 5W-30:-20 to 120°F(-30 to 40 °C) provides the
best protection at all temperatures as well as improved
starting with less oil consumption.
5W-30: 40°F and below (5°C and below) is recommended for
winter use and works best in cold conditions.
16