Permanently lubricated tank mounted air compressor (44 pages)
Summary of Contents for Craftsman 919.167312
Page 1
• Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U,S.A. Visit our Craftsman website: www.sears.corrdcraftsman D29761 Rev. 1 _1_03...
Page 2
HOW TO ORDER REPAIR PARTS ...... back cover FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge.
Page 3
Model No. 919-167312 Max. Developed Running HP Bore 2.38" Stroke 1.36" Voltage-Single Phase 120V/60HZ/1PH Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS.
Page 4
II_ I _e"_b_rki>_ I]_"_d_Ll_"] Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. -" P-_'4'-1 . '1= WARNING: Risk of explosion or fire How To Prevent It What Could Happen It is normal for electrical contacts within...
iri ',ri il, WARNING: Risk of Bursting The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury. What Could Happen How To Prevent It Failure to properly drain Drain tank daily or after each use.
Page 6
; F.'_'_f-q ;t b WARNING: Risk of Electrical Shock WHAT CAN HAPPEN HOW TO PREVENT IT Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used properly Never operate compressor with...
Page 7
WARNING: RISK OF BURNS WHAT CAN HAPPEN HOW TO PREVENTIT Touching exposed metal such as the Never touch any exposed metal parts compressor head or oubet tubes, can on compressor during or immediately after operation. Compressor will remain result in serious burns. hot for several minutes after operation.
Page 8
WARNING: RISK OF UNSAFE OPERATION WHAT CAN HAPPEN HOW TO PREVENT IT Unsafe operation of your air compressor Review and understand all instructions and warnings in this manual. could lead to serious injury or death to you or others. Become familiar with the operation and controls of the air compressor.
Become familiar with these terms When the tank pressure drops to a before operating the unit. certain low level the motor will restart automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
F:_'_"] =1_1 :] I_,,i Contents of Carton Assemble Wheels 1 - Air Compressor It will be necessary to brace or support Wheels one side of the air compressor when installing the wheels because 2 - Shoulder Bolts, 3/8-16 the compressor will have a 2 - Hex Nuts, 3/8-16 tendency to tip.
HOW TO SET UP YOUR This plug MUST be used with a grounded outlet. UNIT IMPORTANT; The outlet being used Location of the Air Compressor must be installed and grounded in accordance with all local codes and Locate the air compressor in a clean, ordinances.
Extension Cords Voltage and Circuit Protection Using extension cords is not Refer to the Parts Manual for the recommended. The use of extension voltage and minimum branch circuit cords will cause voltage to drop requirements. resulting in power loss to the motor Risk of Unsafe and overheating.
Page 13
Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Outlet Pressure Gauge Description of Operation...
Page 14
Motor Overload Protector: The Air Compressor Pump (not shown): Compresses air into the air tank. motor has an automatic reset thermal Working air is not available until the overload protector. If the motor compressor has raised the air tank overheats for any reason, the pressure above that required at the overload protector will shut off the air outlet.
Page 15
Move the On/Auto/Off lever to How to Start: "ON/AUTO" position. The Turn the On/Auto/Off lever to compressor will start. "AUTO" and allow tank pressure Run the compressor for 15 to build. Motor will stop when minutes. Make sure the drain tank pressure reaches "cut-out"...
Customer Responsibilities Before Dailyor each after Every Every each Yeady hours hours Check Safety Valve • Drain Tank • Air Filter 1(1) • Air compressor pump intake and exhaust valves • 1- more frequent in dusty or humid conditions To Check Safety Valve Risk of Unsafe...
Page 17
After the water has been drained, IMPORTANT: Do not operate the close the drain valve (clockwise), compressor with the air filter The air compressor can now be removed. stored. if dirty, rinse air filter with warm NOTE: If drain valve is plugged, water and squeeze dry.
Page 18
All maintenance and repair Unscrew the check valve (turn operations not listed must be counterclockwise) using a 7/8" performed by Trained Service open end wrench. Note the Technician. orientation for reassembly. Using a screwdriver, carefully Risk of Unsafe push the valve disc up and Operation.
Page 19
Assemble the regulator and To Replace Regulator orient as shown. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. Set the On/Auto/Off lever to "OFF" and unplug unit. Remove the outlet pressure gauge and quick connect (if equipped) from the regulator.
Page 20
Before you store the air compressor, Risk of Bursting. make sure you do the following: Water will condense in the air tank. If not Review the "Maintenance" drained, water will corrode and section on the preceding pages weaken the air tank causing a risk and perform scheduled of air tank rupture and possible maintenance...
Risk of Unsafer Operation. Performing repairs may expose voltage sources, moving parts, or compressed air sources. Personal injury may occur. Before servicing: Unplug or disconnect electrical supply to the air compressor, bleed tank of pressure, and allow the air compressor to cool. PROBLEM CAUSE CORRECTION...
Page 22
PROBLEM CORRECTION CAUSE Pressure reading It is normal for "some" If there is an excessive on the regulated _ressure drop to occur. amount of pressure drop pressure gauge when the accessory is used, drops when an adjust the regulator following accessory is the instructions in the...
Page 23
PROBLEM CAUSE CORRECTION Regulator will Damaged regulator. Replace. not shut off air cutlet. Motor will not ! Let motor cool off and Motor overload protection run. overload switch will switch has tripped. automatically reset. Tank pressure exceeds Motor will start automatically )ressure switch "cut-in"...
Page 24
;I I .-la,.[o] LVA I ".J -'I =[.,.",_".[o] ;I _,]F;'Tel - '/_"! _ vj Air Compressor Model Number 919,167312 Torque 100-120 In-Lbs 9-12 Ft-Lbs Torque D29761 24-ENG...
Page 26
_IJkTAI ": I D]r±_,_]-'__,5 L vA Air Compressor Model Number 919.167312 The picture shown is for reference only. It may differ from actual unit. Torque 7-10 Ft-Lbs Torque 100-120 In-Lbs 73 Torque lC0-120 In-Lbs D29761 26- ENG...
Page 27
"1"1"1"1"1"1"1"1"1"_!_ _ IIlI_'T_ Air Compressor Model Number 919.167312 SSF-586 Screw 1/4-20 UNC x .75 AC-0108 SSF-615 Screw 1/4-20 UNC-2A Z-AC-0140 Eccentric Bearing Z-D26712 Motor DAC-16t Shim >x 78 Cylinder Sleeve >x 79 ..Connecting Rod Assembly >x 79-2 CAC-248-2 Formed Compression Ring >...
GARANT|A TOTAL DE UN AI_IO DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman fallase debido a defectos de materiales o de fabricacibn dentro del aSo de su fecha de compra Sears a su opcibn reparar& o reemp azar& s n costo alguno.
Page 29
Modelo N ° 919-167312 M&x. HP desarrollado HP de Tr8bajo Di_,metro interior 2,38 po (60,4mm) Carrera 1,35 po (34,3mm) Tensi6n monof&sica 12OV/60HZ/1 PH Circuito mlnimo requerido Tipo de fusibleAcci6n retardada Capacidad de aire en el tanque 30 Galones (113,6 litros) Presi6n de corte de entrada Presi6n de corte de salida SCFM a 40 psig...
Page 30
GUARDE ESTAS INSTRUCCION_ LA OPERACI6N O EL MANTENIMIENTO INADECUADOS DE ESTE PRODUCTO PODRfAN OCASIONAR SERIAS LESIONES Y DANOS A LA PROPIEDAD. LEA Y COMPRENDA TODAS I.AS ADVERTENCIAS INSTRUCCIONES FUNCIONAMIENTO ANTES DE UTILIZAR ESTE EQUIPO. ADVERTENCIA: RIESGO DE EXPLOSION O INCENDIO &QUE PUEDE OCURRIR?
Page 31
ADVERTENCIA: RIESGO DE EXPLOSION TANQUE DE AIRE: LAS SIGUIENTES CONDICIONES PODRJAN, CAUSAR EL DEBILITAMIENTO DEL TANQUE, Y DETERMINAR SU EXPLOSI(_NVIOLENTA, DAI_IOS A LA PROPIEDAD O SERIAS LESIONES. (.QUI_ PUEDE OCURRIR? _.C6MO PREVENIRLO? 1. Drenaje inadecuado del agua condensada Drene el tanque diariamente o despu6s en el tanque, siendo le causa del 6xido...
Page 32
-uqq[q:{. ADVERTENCIA: RIESGO DE DESCARGA ELI_CTRICA _QUEPUEDE OCURRIR? _.COMO pREVENIRLO? Su compresor de airs est_ accionado por Jamas opera el compresor a fa intemperie cuando est_ Iloviendo o an condition.s electricidad. Como cualquier otro dlspositivo humedad. el_ctrico impulsado electricamente, ei no se Io utiliza adecuadamente, podria causarle Nunca opera el compresor...
Page 33
U _ Nmm(_ .-(D ADVERTENCIA: RIESGO DE QUEMADURAS (.QU¢: PUEDE OCURRIR? _.COMO PREVENIRLO? Tocar el metal expuesto tal cornoel cabezal Jam;is toque partes de metal expuestas en el del compresoro los tubos de salidadel escape, compresor durante o inmediatamente despu6s de la operacibn, el compreeor permanecer;i puede ocasionarle serias quemaduras.
Page 34
J =lal[tl;{a ADVERTENCIA: RIESGO DE OPERACI6N INSEGURA ;,,COMe PREVENIRLO? _,QUE PUEDE OCURRIR? La operacion insegura de su compresor de airs Revise y comprenda todas las instrucciones y podria ocaslonarlo =erias leslones o la muerte advertenciae contenidas en este manual. a ueted u otros. Familiaricese con los m6todos de operaci6n control del compresor de airs.
Page 35
Familiarfcese con los siguientes t_rminos, Presibn minima de corte: Cuando el antes de operar la unidad: motor est& apagado, la presi6n del tanque CFM: (Cubic feet per minute) Pies c_Jbicos de aire baja a medida que usted continua pot minuto. usando su accesorio.
Page 36
Ensamble de las ruedas Contenido de la caja 1- Compresor de aire 2- Ruedas del equipo cuando se inetalan las ruedas porque el compresor tendera 2- Pernos con resalto, 3/8" - 16 voltearse. 2- Tuercas hexagonales, 3/8" - 16 Fije ras ruedas con pernos con 2- Paraehoques de goma resalto y tuercas como se muestra.
C(_MO PREPARAR LA UNIDAD Asegt3resede que el tomacorriente que ser_ uSlizado tenga la misma configuraciSn que el enchufe de conexibn Ubicaci6n del compresor de aire a tierra. Ubique al compresor de aire en una zona NO UTILICE UN ADAPTADOR. limpia, seca y bien ventilada. La bomba figura.
Page 38
Cables de extenai6n el6ctrica Protecci6n del voltaje y del circuito No se mcomienda la utilizaci6n de cables Acerca del voltaje y la minima cantidad de de extensibn el_ctrica. El use de cables circuitos requeridos, refi6rase al cuadro de extensibn el_ctrica origJnarb una ca[da de espeeificaciones.
Page 39
Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD. Compare las ilustraciones contra su unidad a fin de familiarizarse con la ubica¢i6n de los distintos controles y regulaciones. Consanle este manual para referencias futuras.
Page 40
Bomba de compresi6n del aire (no autom&ticamente una vez enfriado el motor. mostrada): Comprime el aire dentin del Si el protector de sobrecarga apaga el tanque. El aim de trabajo no se encuerTtra motor con mucha frscuenaia, vedfique ai disponible basra que el compresor haya hay alg_n poaible problerna de voltaje.
Page 41
Cdmo poner en marcha: Antes de cada puesta en marcha: Mueva Is palanca On/Auto/Off a la Coloque el interruptor On/Auto/Off en la posici6n "AUTO" y deje que se posici6n "OFF" y cierre el regulador de incremente la presi6n del tanque. El aire.
Page 42
l_Vff__1 _11/_l _I hVd 1=l_o] Responsabilidades del cliente Diarlamsnts Cada! Cads Antes Anualmente de cada o luego de cads uso horas horas Verifique la vdlvula de seguridad Drenaje del tanque Filtro de aire o(_) • Vdlvulas de entrada y escape de la bomba del compresor de airs 1- M&s frecuente en condiciones polvorientas o hQmedas.
Page 43
Extraiga el ret_n del fUtro de aire. Riesgo de Explosi6n. Dentro Retire el filtro de aire y aseg_rese de del tanque se producird condensaci6n que est6 limpio. de agua. Si no drena, el agua Io IMPORTANTE: No opere el compresor corroerd y debilitard causando un sin el filtro de aire.
Page 44
Todo tipo de mantenimiento y v&lvula de retenci6n. operaciones de reparacidn no Desenrosque la vdlvula de retenci6n mencionados, deberdn eer efectuados gir{mdola hacia la izquierda usando por personal tdcnico especializado. una Ilave de boca de 7/8 plug. (22 mm). Tome nora de la Riesgo de orientacibn para volverla a...
Page 45
Ensamble el regulador y ori6ntelo de Para reemplazar el regulador acuerdo a Io mostrado. Libere toda la presi6n del aire del tanque. Vea "Drenaje del tanque" en la seccibn "Mantenimiento". Apagar la unidad colocando ei interruptor en On/Auto/OFF "OFF". Usando una Ilave de tuercas ajustable retire el medidor de salida de presi6n y la conexibN rdpida del regulador (si...
Page 46
Antes de guarder su compresor de 8ire, Riesgo de Explosi6n. El aseg_rese de hecer Io siguiente: ague se condensa dentro del tanque de Revise la secci6n "Mantenimiento" aire. Si no se drena, ella de las p_,ginas precedentes y ejecute el mantenirniento programado de corroer&...
Page 47
_= I _]P';Tqr_L_--,,_o] ID]=I_o_ Riesgo de Operaci6n Insegum: La unidad arranca automdticamente cuando estd enchufada. AI hacer el mantenimiento, el operador puede quedar expuesto a fuentes de corriente y de aire comprimido o a piezas movibles. Antes de intentar hacer repamciones, desconectar compresor del tomacorriente, drenar la presi6n de aim del tanque y esperar a que el compresor se enfrie.
Page 48
PROBLEMA CORRECCION CAUSA La lectura de la Si hubiese una caida excesiva de Es normalqueocurra algL_n descenso on la presi6n, _resibn durante el uso del presi6n sobre un man6metro accesorio, ajuste el regulador de acuerdo alas instrucciones de la viene equipado con este) secci6n Operaci6n.
Page 49
PROBLEMA CAUSA CORRECCION El motor no El interruptor de protecciOn des Deje enfriar el motor y el funciona, obrecarga del motor se ha interruptor de sobrecarga abierto. reajustar_ automdticamente. El motor arrancar& autorn_ticamente La presiOn del tanque excede la presiOn de "corte mdximo" cuando la pmelbn del tanque caiga del interruptor de presiOn.
Page 51
Reparaciones Congratulations on making a smart Felicitaciones per hater una compra purchase. Your new Craftsman ® product is inteligente. Su nueva unidad Craftsman ® est& designed and manufactured for years of disedada y fabricada para ares de operaci6n dependable operation.
Page 52
Your Home ....For repair - in your home - of all major brand appliances, lawn and garden equipment, or heating and cooling systems, i_i_ no matter who made it, no matter who sold it! ii_;i For the replacement parts, accessories and ..