Configure the settings relating to the alarm output terminal [Alarm]

Click the [Alarm] tab on the "Alarm" page. (☞ Pages 22 and 23: How to display/operate the setup menu)
The settings relating to the alarm output terminal can be configured in this section.
■ Alarm output terminal setup
[Alarm output trigger]
Select "On" or "Off" to determine whether or not to out-
put the alarm signals to the alarm output terminal when
an alarm is detected.
Default: Off
[Alarm output type]
Select "Latch" or "Pulse" for the alarm output terminal
at an alarm occurrence.
Latch: When an alarm is detected, the alarm output
terminal will be in the state selected for "Trigger out-
put" until the alarm occurrence indication button is
clicked.
Pulse: When an alarm is detected, the alarm output ter-
minal will be in the state to the "Trigger output" set-
ting for the period set for "Pulse width".
Default: Latch
[Trigger output]
Select "Open" or "Close" to determine whether to open
or close the alarm output terminal when outputting the
alarm signals.
Open: The alarm output terminal will open when out-
putting the alarm signals. (Normally close)
Close: The alarm output terminal will close when out-
putting the alarm signals. (Normally open)
Default: Close
Note:
• When "Open" is selected, the alarm signal will be
output for around 20 seconds when the power of
the camera is turned on.
[Pulse width]
When "Pulse" is selected for "Alarm output type",
select an alarm output terminal duration from the fol-
lowing.
Available range: 1 - 120sec
Default: 1sec