Summary of Contents for Craftsman 919.152390

  • Page 1 Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating. Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. Visit our Craftsman website: www.sears.com/eraftsman D29477 Rev0 8/22/03...
  • Page 2 FULL ONE YEAR WARRANTY AIR COMPRESSOR If this CRAFTSMAN Air Compressor fails due to a defect in material or workmanship within one year from the date of purchase, Sears will at its option repair or replace it free of charge. Contact your nearest Sears Service Center (1-800-4-MY-HOME ®)to arrange for repair, or return the Air...
  • Page 3 _'J :(a_ 13 [o-7-_ i [o] _I[a_: r-! :t Model No. 919-152390 Bore 1.875" Stroke 1.25" Voltage/Hertz/Phase 120V/60/1 Minimum Branch Circuit Requirement 15 amps Fuse Type Time Delay Air Tank Capacity (gallons) Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig B'T:I d =i ib'd[€'IlJl,] _ NI_I:_ *- I,] _ all,lid [o]_...
  • Page 4 Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment. ." f ._IrJ_.-lu WARNING: Risk of explosion or fire What Could Happen How To Prevent It tt is normal for electrical contacts Always operate the compressor in a well...
  • Page 5 WARNING: Risk of Bursting Air Tank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury, What Could Happen How To Prevent It Failure to properly drain condensed Drain tank daily or after each use.
  • Page 6 -"W.'_4.'_ -'{D WARNING: Risk of Electrical Shock What Could Happen How To Prevent It Your air compressor is powered by Never operate the compressor outdoors electricity. Like any other electrically when it is raining or in wet conditions. powered device, If it is not used Never operate compressor with properly...
  • Page 7 WARNING: Risk of Burns How To Prevent It What Could Happen Never touch any exposed metal parts Touching exposed metal such as the on compressor during or immediately compressor head or outlet tubes, can after operation, Compressor will remain result in serious burns. hot for several minutes after operation.
  • Page 8 WARNING: Risk of Unsafe Operation What Could Happen How To Prevent It Review and understand all instructions Unsafe operation of your air compressor and warnings in this manual. could lead to serious injury or death to Become familiar with the operation you or others.
  • Page 9 [,]][,I-'_" f.'_-'_'4 Become familiar with these terms When the tank pressure drops to a certain low level the motor will restart before operating the unit. automatically. The low pressure at CFM: Cubic feet per minute. which the motor automatically SCFM: Standard cubic feet per restarts is called "cut-in"...
  • Page 10 [_,.--,].,.-,] =1 _v_ I :] I_'d Contents of Carton Assemble Accessories 1 - Air Compressor Choose the accessory needed. Assemble Female Tire Chuck 1 - Air Hose Assemble female tire chuck to 1 - Female Tire Chuck hose and tighten securely with 1 - Inflator Accessory Kit wrenches.
  • Page 11 The cord set and plug with this HOW TO SET UP YOUR unit contains a grounding pin. UNIT This plug MUST be used with a grounded outlet. Location of the Air Compressor Locate the air compressor in a clean, IMPORTANT: The outlet being used dry and well ventilated area.
  • Page 12: Specification Chart

    Extension Cords Voltage supply to circuit must comply with the National If an extension cord must be used, be Electrical Code. sure it is: Circuit is net used to supply any • a 3-wire extension cord that has other electrical needs. a 3-blade grounding plug, and a 3-slot receptacle that will accept Extension cords comply with...
  • Page 13 Know Your Air Compressor READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Regulator Off/Auto Switch Safety Valve Outlet...
  • Page 14: Accessories

    Female Tire Chuck: Attaches to the How to Use Your Unit hose end to be used to inflate tires. How to Stop: Note: To ensure correct tire pressure use a tire pressure gauge. Set the Off/Auto switch to "OFF". Hose Adapter: Attaches to hose end to allow the use of accessories.
  • Page 15 How to Start: Before Each Start-Up: Place Off/Auto switch to "OFF" Turn the Off/Auto switch to and close air regulator. "AUTO" and allow tank pressure to build. Motor will stop when Turn the regulator knob tank pressure reaches "cut-out" counterclockwise until it stops.
  • Page 16: Maintenance

    Customer Responsibilities Before Daily or each after each Check Safety Valve • Drain Tank Place unit on blocks to lift unit off Risk of Unsafe of ground. Operation. Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts.
  • Page 17: Storage

    Before you store the air compressor, Wrap the electrical cord loosely make sure you do the following: around the unit and snap it into itself for storage. Drain tank, see "To Drain Tank" paragraph in the "Maintenance" section of this manual for the correct procedure.
  • Page 18 d-'{tlll-ll :!,,.1 -"[tlti d I_[l Risk of Unsafe Operation. Performing repairs may expose voltage sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM CAUSE CORRECTION...
  • Page 19 PROBLEM CAUSE CORRECTION Decrease amount of air Compressor is Prolonged excessive use of air. not supplying usage. enough air to Compressor is not large Check the accessory air operate accessories. requirement. If it is higher enough for air requirement. than the SCFM or pressure supplied by your air compressor, you need a larger compressor.
  • Page 20 Air Compressor Model Number 919.152390 Part No. Description Z-D30180 Rubber Bumper Kit (includes 4) Z-D29379 Storage Bag Kit D29477 20- ENG...
  • Page 21: Notes/Notas

    GARANT|A TOTAL DE UN AI_O DEL COMPRESOR DE AIRE Si este compresor de aire Craftsman faliase debido a defectos de materiales o de fabricaci6n dentro del aSo de su fecha de compra, Sears, a su opci6n, Io reparar& o reemplazara sin costo alguno.
  • Page 22 Modelo N ° 919-152390 Di&metro interior 2,875 pulg. (73,0 ram) Carrera 1,25 pulg. (31,8 ram) 120/60/1 Voltaje/Hereios/Fases Circuito minimo requerido Aeci6n retardada Tipo de fusible Capacidad de aire en el tanque 1.5 Galones (5,6 litros) Presi6n de corte de entrada Presi6n de corte de salida 3,0 Calibre de libras SCFM a 40 psig...
  • Page 23 GUARDE ESTAS INSTRUCCIONES La operaci6n o el mantenimiento inadecuados de este producto podrian ocasionar serias lesiones y daSos a la propiedad. Lea y comprenda todas las advertencias instrucciones de funcionamiento antes de utilizar este equipo. "J:=im [_ ;{_ ADVERTENCIk Riesgo de Explosibn o Incendio qud puede ocour_r c6mo prevenirlo...
  • Page 24 "J=iq It1 t,{I ADVERTENCIA: Riesgo de Explosibn de aire: las siguientes condiciones podrian, causar el debilitamiento del tanque, determinar su explosi6n violenta, daSos a la propiedad o serias lesiones. qud puede occurrir cbmo prevenirlo Drenaje inadecuado del agua condensada Drene el tenque diarlamente o despu_s de en el tenque, siendo la causa del 6xide que...
  • Page 25 J:4aq [t'l _,{e ADVERTENCIA: Riesgo de Descarga El_ctrica qu_ puede occurrir c6mo prevenirlo Su compresor de aire est& accionado por JamAs opere e_compresor a la intemperie electricidad. Como cualquier otto dispositivo cuando estA {_oviendo o en condiciones ei_ctdco impulsado el6ct ficamente, si no se Io humedad.
  • Page 26 ADVERTENCIA: Riesgo de Quemaduras qu_ puede occu_ir c6mo prevenirlo Jam&s toque partes de metal expuestas en el Tocar el metal expuesto tal como el cabezal compresor durante o inmediatamente despu_s del compresor o {os tubos de salida del de la operaci6n, el compresor permanecer&...
  • Page 27 ADVERTENCIA: Riesgo de Operacibn Lasegura qu_ puede occurrir c6mo prevenirlo La operacion insegura de su compresor de Revise y comptenda todas _asinstrucciones y aire podria ocasionarle serias lesiones o la advertencias contenidas en este manual. muerte a usted u otros. Familiaricese con los mbtodos de operacibn y control del compresor de aire.
  • Page 28 Presi6n minima de torte: Cuando el Familiaricese con los siguientes t6rminos, antes de operar la unidad: motor est& apagado, la presi6n del tanque de aire baja a medida que usted eontin0a CFM: (Cubic feet per minute) Pies c0bicos usando su accesorio. Cuando la presi6n per minute, del tanque baja a! valor fijado en f&brica...
  • Page 29 Contenido de la Caja Ensamblaje de Accesorios Compresor de aire Seleccione el accesorio requerido. Ensamblaje de la Boquilla Hembra Manguera de aire para Mantas Boquilla hembra para Hanta Instale la boquilla hembra para Herramientas necesarias para Ilantas en ]a manguera y ajQstela ensamblar firmemente con una Ilave.
  • Page 30 C(_MO PREPARAR LA UNIDAD Asegt3rese de que el tomacorriente que set& utilizado tenga la misma Ubicacibn del compresor de aire configuraci6n que el enchufe de conexi6n a tierra, NO UTILICE UN Colocar el compresor de aire en un lugar ADAPTADOR. Vet figura. limpio, seso y bien ventilado, alejado pot Io menos 30cm (12") de les paredes o de cualquier otra obstruesiSn que intertiera con...
  • Page 31 Cables de extensi6n eldctrica Que el voltaje suministrado a trav6s de los ramales del eircuito sea de 15 A. Si - no obstante - debe utilizarse una extenai6n de cable, seegQrese de que: Que el circuito no sea utilizado para La extensi6n el6ctrica de 3 alimentar ninguna otra necesidad conductores,...
  • Page 32 Conozca su compresor de aire LEA ESTE MANUAL DEL PROPIETARIO Y SUS NORMAS DE SEGURIDAD ANTES DE OPERAR LA UNIDAD+ Compare las ilustraciones centre su unidad a fin de familiarizarse con la ubioaci6n de los distintos controles y regulaciones. Conserve este manual para referencias futures+ Regalador Interruptor...
  • Page 33 C6mo utilizar su unidad Vdlvula para nantas: Se conecta al extreme de la manguera de aire y se usa C6mo detenerla: para inflar Ilantas. Nota: Para asegurarse de Coloque la posici6n de la llave la presi6n correcta de la Ilanta, use un interruptora Off/Auto en la posici6n medidor de presi6n para Jlantas.
  • Page 34 Antes de cada puesta en marcha: CSmo poner en marcha: Coloque el interruptor Off/Auto en la Mueva la palanca Off/Auto a la posici6n posici6n "OFF" y oierre el regulador de "AUTO" y deje que se incremente la aire. presiSn del tanque, El motor se detendra una vez alcanzado el valor de presiSn "de Girar la periHadel regulador hasta que se carte"...
  • Page 35 v_ V_,_ _ i d_ _ II_V_ll _ _i I[O Responsabilidades del cliente Antes C_a_arr_ cada o IL_go d e cadauso Verifique la v&lvula de seguridad Drenaje del tanque Co!ooar la unidad sobre bloques pare Riesgo de Operaci6n levantarla del piso. Insegura.
  • Page 36 Antes de guardar el compresor de aire, Pare guardar el cord6n el6ctrieo, aseg_rese de hacer Io siguiente: enr611elo en forma suelta y enganche el enchufe en el cord6n. Drene el tanque. Pare el proeedimiento correcto, yea el p&rrafo "Drenaje del Tanque" en la secei6n "Mantenimiento"...
  • Page 37 El desarrollo de reparaciones puede exponer a sitios con corriente viva, partes en movimiento o fuentes aire comprimido que podrian ocasionar lesiones personales. Antes intentar reparaoi6n alguna, desenehufe el oompresor de aire y purgue toda la presi6n de aire del tanque. CORRECCI()N CAUSA PROBLEMA...
  • Page 38 CORRECCI(_N CAUSA PROBLEMA El Compresor no Excesivo y prolongado uso del Disminuya la cantidad de uso de esta aire. aire, suministrando suficiente El compresor no tiene Verifique el requerimiento de aire cantidad de aire suficiente capacidad para el del accesorio. Si es mayor que para SCFM o la presi6n suministrada requerimiento...
  • Page 39 39-SP D29477...
  • Page 40 Get it fixed, at your home or ours! Your Home For repair - in your home - of all major brand apphances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner's manuals that you need to do-it-yourself For Sears professional installation of home appliances...