26 Acceleration time setting 1
Acceleration time setting 2
27 Second acceleration time setting
28 Acceleration curve selection
29 Acceleration curve constants setting
30 Deceleration time setting 1
Deceleration time setting 2
31 Second deceleration time setting
32 Deceleration curve selection
33 Deceleration curve constants setting
34 Acceleration stop frequency setting
35 Acceleration stop time setting
36 Operation mode selection
37 Resume on free-run stop cancellation mode
38 Multi-speed frequency setting 1
39 Multi-speed frequency setting 2
40 Multi-speed frequency setting 3
41 Multi-speed frequency setting 4
Multi-speed frequency setting 7
42 DC braking enable
43 DC braking / edge or level detection
44 DC braking frequency setting
45 DC braking force for starting
46 DC braking force during deceleration
47 DC braking time for starting
48 DC braking time during deceleration
49 DC braking wait time
50 Dynamic braking usage ratio
51 Electronic thermal characteristic 1
Electronic thermal characteristic 2
52 Level of electronic thermal setting 1
Level of electronic thermal setting 2
53 Free setting, electronic thermal current 1
54 Free setting, electronic thermal frequency 1
55 Free setting, electronic thermal current 2
56 Free setting, electronic thermal frequency 2
57 Free setting, electronic thermal current 3
58 Free setting, electronic thermal frequency 3
59 Overload restriction setting
60 Overload restriction constant setting
61 Overload restriction, enable for acceleration
No.
Name
setting
Digital
Remote Operator
operator
F6
F-06 ACC1
30.0
F6
ACC1
30.0
F6
ACC2
15.0
-
ACC LINE
L
-
ACC GAIN
02
F7
F-07 DEC1
30.0
F7
DEC1
30.0
F7
DEC2
15.0
-
DEC LINE
L
-
DEC GAIN
02
-
F-08 FSP F
0.0Hz
-
FSP TIME
0.0s
A59
F-10 RUN MODO
NOR
A54
RUN FRS
ZST
A12
F-11 SPD 1
0.00
A13
SPD 2
0.00
A14
SPD 3
0.00
F2
SPD 4
0.00
F2
SPD 7
0.00
-
F-20 DCB SW
OFF
-
DCB KIND
LVL
-
DCB F
0.5Hz
-
DCB V-STA
00
-
DCB V-STP
00
-
DCB V-STA
0.0s
-
DCB V-STP
0.0s
-
DCB STOP-T
0.00s
A38
F-21 BRD-%ED
1.5%
A24
F-23 E-THM CHAR
SUB
A24
E-THM CHAR
SUB
A23
E-THM LEVEL
100%
A23
E-THM LEVEL
100%
-
E-THM A1
Factory set
-
E-THM F1
Factory set
-
E-THM A2
Factory set
-
E-THM F2
Factory set
-
E-THM A3
Factory set
-
E-THM F3
Factory set
-
F-24 OLOAD LEVEL
125%
-
OLOAD CONST
1.0
-
OLOAD ACC
ON
J300
Function code
Default
20/24
code
(Digital
operator)
F002
30.00
F202
30.00
Second acceleration time (A292) can be also set in the case
A092
15.00
of the SJ300.
A097
00
A131
02
F003
30.00
F203
30.00
Second deceleration time (A293) can be also set in the case
A093
15.00
of the SJ300.
A098
00
A132
02
A069
0.00
A070
0.0
A085
00
b088
00
A021
0.00
A022
0.00
A023
0.00
A024
0.00
0.00
A051
00
A056
01
A052
0.50
A057
0.
DC braking carrier frequency (A059) can be also set in the
case of the SJ300.
A054
0.
A058
0.0
A055
0.0
A053
0.0
SJ300 have dynamic braking control (b095) and dynamic
b090
0.0
braking activation level setting (b096).
b013
00
Can be set up to 3
b213
00
b012
Rated current
Can be set up to 3
b212
Rated current
b016
0.0
b015
0.
b018
0.0
b017
0.
b020
0.0
b019
0.
b022
Rated current x1.5
Two sets of overload restriction parameter settings and
values are available in the case of the SJ300. (b025, b026,
b023
1.00
b024) Selection can be made by OLR function assigned to an
b021
01
intelligent input terminal.
SJ300
Function
Default setting
rd
motor (b313) in the case of the SJ300.
rd
motor (b312) in the case of the SJ300.
Remarks

Advertisement

Table of Contents
loading

This manual is also suitable for:

J300 series

Table of Contents