INITIAL USE INSTRUCTIONS
ENGINE OIL
The generator is shipped
1.
Place the generator on a level surface.
2.
Loosen the cover screw and remove the maintenance cover.
MAINTENANCE COVER
3.
With the generator in a level position, remove the oil filler cap/
dipstick.
4.
Add enough SAE 10W-30 API service category SJ or later (or
equivalent) oil to bring the oil level to the upper limit of the oil filler
neck. SAE 10W-30 oil is recommended for general use; for
additional recommendations, see page
Do not overfill the engine with oil.
excess oil may be transferred to the air cleaner housing and air filter.
5.
Screw in the oil filler cap/dipstick securely.
OIL FILLER CAP/DIPSTICK
6.
Reinstall the maintenance cover.
78
WITHOUT OIL
COVER SCREW
If the engine is overfilled, the
in the engine.
46
.
UPPER LIMIT
Need help?
Do you have a question about the EU2000i Companion and is the answer not in the manual?
Questions and answers