Replacing the WWN bezel (logo plate) and WWN card

ATTENTION
Follow ESD precautions
1. Unpack the new WWN card and save the packaging for the faulty WWN card.
2. Hold the card by the pull tab and insert the WWN cable onto the WWN module until it is fully
3. In the CLI session, enter continue to indicate that the replacement has been completed.
4. Verify that the WWN card is correctly connected by checking the LED on the WWN card.
5. Install the WWN bezel. Orient the bezel on the chassis
6. Pack the faulty WWN card in the packaging provided with the new card and return it to the

RRP: SFPs and XFPs

NOTE
The 8-Gbps SFPs autonegotiate at 2, 4, and 8 Gbps. The 4-Gbps SFPs autonegotiate at 1, 2, and 4
Gbps.
To remove an SFP or XFP (FC6-10 blade only) transceiver, pull the bale down and out, sliding the
transceiver out of the port or application blade.
To install an SFP or XFP, position one of the transceivers so that the key is oriented correctly to the
port. Insert the transceiver into the port until it is firmly seated and the latching mechanism clicks.
Transceivers are keyed so that they can only be inserted with the correct orientation. If a
transceiver does not slide in easily, ensure that it is correctly oriented.
The PowerConnect B-DCX-4S comes with a transceiver extraction tool
extraction tool is designed to remove transceivers from blades where the space is limited. To use
the extraction tool, slide the tool on to the bale of the transceiver and pull it out.
PowerConnect B-DCX-4S Backbone Hardware Reference Manual
53-1001808-01
("ESD
seated. Use the Phillips screwdriver and the two screws to attach the WWN card to the chassis.
NOTE
If a serial console session is active, several "removal detected" and "insertion detected"
messages display on the console because of the replacement.
Please enter the word `continue' after the new WWN card has been installed:
continue
Restoring the information to the replacement FRU now, please wait about 20
seconds to complete
Verifying the replacement FRU now...
WWN card hot swap is now complete.
FRU replacement completed successfully!
NOTE
The LED might take up to 2 minutes after WWN card installation to begin functioning.